CONNECTED wireless connection of FireSAFE devices
Wireless Fire and Temperature Detector

SAFE 10YHT - RF
New generation wireless heat rise detector designed for fire detection that is not accompanied by smoke and provides early warning of impending danger upon detecting a sudden rise in temperature in the monitored area. The detector features SIC technology for temporarily silencing the alarm using an IR remote control and can operate as part of the FireSafe fire security system with support for the FireSAFE Hub central control unit or completely autonomously. Power is supplied by an integrated lithium battery guaranteed to provide an exceptionally long operation of 10 years, with a 10-year warranty on both the battery and the device itself.
Description of the Device
Wireless Fire and Temperature Detector with a 10-Year Warranty
New generation wireless rate-of-rise heat detector equipped with an A1 class thermistor for detecting fires not accompanied by smoke. The detector reliably provides early warning of imminent fire hazards by detecting a rise in temperature in areas where false alarms from smoke detectors with optical detection technology might occur due to high humidity, fumes, chemicals, dust, or the presence of smoke particles.
SAFE 10YHT – RF is designed in a low-profile compact design, combining the latest hardware and software technology applied to the functional structure of an intelligent detector representing a new standard in residential fire safety.
Wireless Communication in the FireSAFE Network
The detector includes an integrated RF module, which thanks to the CONNECTED function allows you to wirelessly link two or more FireSAFE detectors and thus create an interconnected wireless network. In such a case, if one of the devices triggers an alarm, it will send a radio signal and all other FireSAFE units connected in the network will also respond to the alarm.
FireSAFE System With a Central Control Unit
A smart central control unit, the Hub FireSAFE, can be added to the wireless network. These units then allow convenient setup and control of the comprehensive FireSAFE system, even remotely, thanks to an internet connection, using the intuitive free mobile app of the same name (for Android and iOS) designed for smartphones, tablets, and more. The Hub monitors the activity of all connected FireSAFE detectors and devices and immediately informs the system user via push notifications in case of detected danger.
Unique Technology of the Predictive Algorithm and Thermistor Sensor
The SAFE 10YHT – RF thermistor fire temperature detector was designed for a wide range of applications and environments where reliable fire detection cannot be ensured using conventional technologies. It provides an effective solution for detecting fires with a rapid rise in temperature during combustion or for slowly developing fires that generate a temperature increase in the monitored area. For detection, the detector uses intelligent predictive algorithm technology in combination with a Class A1 thermistor sensor, structurally designed outside the housing to ensure immediate alarm response without further delay.
Responding only to Real Threats
In fire detection systems in residential buildings, the priority is to inform people in a timely manner about an imminent real danger. AI SAFE microprocessor was developed based on a detailed analysis of the burning properties of materials and operates with a predictive algorithm that compares data from a thermistor sensor and filters out potential false alarm possibilities. It evaluates the measured temperature in real time, comparing it with the rate of increase and predictive patterns for reliable and timely warning of potential fire hazards. If the dynamics of the data pattern match the actual parameters of a developing fire temperature, the detector immediately triggers the fire alarm.
Fire Alarm Signalization
In the event that the set temperature limit is exceeded during detection, the detector will automatically activate a loud acoustic alarm signal at 85 dB, accompanied by the flashing of a red LED indicator to signify a fire alarm. This is intended to attract the attention of individuals in the building through a high noise level and intense LED signaling that a fire has occurred in a part of the facility. The purpose of the fire alarm is then to prompt an immediate response to the alarm event or to move people from the site of the emergency to a safe zone.
SIC Technology and Remote Alarm Silencing by IR Remote Control
The detector features a combined button with TEST and MUTE functions, which is designed both for testing and verifying the correct operation of the device, as well as for temporary silencing of the alarm. In the event that you know the cause of the fire alarm activation and need to silence the loud acoustic siren signal, there is no need to go through any complicated procedure to reach the alarm itself in order to silence it using the button. SIC technology allows you to remotely silence the acoustic signal by pressing any button on a standard IR remote control (most remote controls for household appliances, for example for a TV).
With IZOVAX Protection also for Rooms with Increased Humidity
The electronic components and printed circuit board of the detector are equipped with an insulating and protective varnish layer with IZOVAX nanoparticles, and thanks to innovative thermistor sensing technology, unlike conventional optical fire detectors, the device can be installed in a wide range of complicated environments (bathrooms, drying rooms, saunas, swimming pools, kitchens, garages, boiler rooms, workshops, warehouses, laboratories, etc.), where humidity, vapors, chemical substances, dust, or the presence of smoke particles could affect the function of conventional optical fire detectors.

Guaranteed Operational Performance for an Entire Decade
Power is provided by an integrated 3V lithium battery (built-in, non-replaceable) guaranteeing an exceptionally long detector operation of more than 10 years. Battery operation enables quick and easy installation and ensures proper functioning of the smoke and fire detector for more than 10 years from activation. The battery is activated when the detector is placed and secured in the mounting bracket. After 10 years of protection, with a 30-day advance notice, the detector will announce the end of its service life and automatically alert you that it needs to be replaced. The extended 10-year warranty covers both the battery and the device itself.
Technical Specifications
- Model
- Sensor technology
- Microprocessor
- Remote alarm silencing
- Alarm at temperature range
- Time measurement interval
- PCB protection
- Power Supply
- Alarm Signalization
- Working Radio Frequency
- Maximum Number of Connected Devices
- Radio signal range
- Mounting
- Installation
- Operating Temperature
- Operating Humidity
- Storage Conditions
- Dimensions
- Package Dimensions
- Product Weight
- Package Weight
- Quantity per carton
- Carton Dimensions
- Weight of the carton
- Certification
- Declaration of Comformity (DoC)
- Warranty
- EAN code