FireSAFE / Standalone products

Standalone smoke alarm
SAFE 10Y30-PRO

User manual

Updated 13 October 2026

Product page Datasheet (PDF)
The SAFE 10Y30-PRO alarm

SAFE 10Y30-PRO is a new generation of standalone smoke alarm with breakthrough detection using a dual-spectrum, dust-resistant optical chamber and SIC technology for temporarily silencing the alarm using an IR remote control. Power is supplied by an integrated lithium battery (built in, non-replaceable) guaranteeing exceptionally long operation of the device of more than 10 years and an extended 10-year warranty on both the battery and the device itself. The SAFE 10Y30-PRO fire alarm sets a new level of standard in the fire safety of residential buildings.

10 yearsoperation on the integrated battery
85 dBacoustic fire alarm
24 hactive protection every day
9 minalarm silence time
20–40 m²max. protected area
10 yearswarranty on the device and battery
Dual-spectrum optical sensor for smoke detection
Protection against foreign bodies
SIC remote alarm silencing with an IR remote control
10 years of battery operation
IZOVAX protection
EN 14604 certification and extended warranty

Foreword

General

This user manual describes the installation, functions and operation of the SAFE 10Y30-PRO standalone smoke alarm (hereinafter the “alarm”). The alarm works completely independently, with no need to connect to a Hub or mobile app. Read the manual carefully before using the device and keep it for future reference.

Safety instructions

The following signal words may appear in the user manual:

Signal wordMeaning
NEBEZPEČÍIndicates a high potential hazard which, if not avoided, may result in death or serious injury.
VAROVÁNÍIndicates a medium or low potential hazard which, if not avoided, could result in minor or moderate injury.
UPOZORNĚNÍIndicates a potential risk which could lead to property damage, data loss, reduced performance or an unpredictable result.
TIPProvides methods to help you solve a problem or save time.
POZNÁMKAProvides additional information, such as emphasis or a supplement to the text.

Revision history

VersionRevision contentRelease date
V1.0.0First release.September 2026
V1.0.1Colours according to the FireSAFE brand (red).October 2026

About the manual

Operating requirements

VAROVÁNÍ
UPOZORNĚNÍ

Installation requirements

VAROVÁNÍ
UPOZORNĚNÍ

Functional elements

Functional elements of the SAFE 10Y30-PRO alarm – front with the LED indicator, buzzer and TEST/Silence button, back with the battery location
Functional elements of the SAFE 10Y30-PRO alarm
  1. LED indicator – visually signals the states of the individual modes of the device (see Signalling).
  2. Buzzer – alarm volume 85 dB (A) at a distance of 3 m.
  3. TEST/Silence button – verifies the functionality of the device; also used to temporarily silence the acoustic alarm signal.
  4. Battery location – on the back of the alarm, built-in battery, not user-replaceable.

Principle of operation

The smoke alarm is designed for continuous monitoring, detection and signalling of smoke. The device uses advanced split-spectrum photoelectric chamber technology, a built-in loud alarm buzzer, fast response to hazard detection combined with high sensitivity, stable performance and high resistance to false alarms. As soon as the smoke concentration around the sensor reaches the alarm level, the alarm immediately triggers an acoustic and visual alarm signal to inform the user of the approaching danger.

Dual-spectrum smoke chamber

A dual-spectrum optical sensor with blue and infrared LED sources of different wavelengths is integrated into a dust- and insect-resistant smoke detection chamber. The chamber design with a direct link to the microprocessor AI SAFE offers the most reliable detection method, which, combined with a predictive algorithm, enables measurement of the concentration of microparticles directly in the air in real time. This technology can determine the size of volatile particles inside the optical chamber and respond only to a real threat in the form of smoke, while ignoring the similar composition of water vapour or other fumes.

Protection against false alarms

The AI SAFE microprocessor was developed on the basis of a detailed analysis of the combustion properties of materials and works with a predictive algorithm that compares data from the dual-spectrum optical sensor and filters potential false alarms in real time. If the recorded data correspond to liquid particles of water vapour or other types of fumes, the alarm will not react. However, if the dynamics of the data pattern correspond to the real parameters of the solid smoke particles of a fire, the alarm immediately triggers a fire alarm.

SIC technology – remote silencing with an IR remote control

The alarm has a combined button with TEST and Silence functions, which is used both for testing and verifying the correct functioning of the device and for temporarily silencing the alarm. If you know the cause of the fire alarm activation and need to silence the loud acoustic signalling, there is no need to reach the alarm directly – the technology SIC allows remote silencing of the acoustic signalling by pressing any button on an ordinary IR remote control (most remote controls for household appliances, for example for a TV).

IZOVAX protection for damp spaces

The alarm's electronic components and printed circuit board are coated with an insulating and protective layer of varnish with nanoparticles IZOVAX. Thanks to this, and to the dual-spectrum optical chamber technology, which distinguishes smoke particles from water vapour, the device can, unlike conventional fire alarms, also be installed in very humid environments (near bathrooms, drying rooms, kitchens or utility rooms).

Guaranteed operating performance for a whole decade

Power is supplied by an integrated 3 V CR123A lithium battery (built in, non-replaceable), guaranteeing exceptionally long operation of the alarm of more than 10 years. The power battery is activated when the alarm is placed and locked into the mounting bracket. After 10 years of protection, and 30 days in advance, the alarm announces the end of its life and automatically warns that it needs to be replaced (see End of life).

Signalling

LED indication / soundEvent
Short buzzer beep + red LED flashDevice activation after insertion into the mounting bracket; a short initialisation follows
Green LED flashes 1× every 60 sStandby (operating) mode – everything is in order
Short buzzer tone + red LED flashShort press of the TEST/Silence button – confirmation of functionality
Red LED flashes 1× per second + buzzer beeps 1× per second (repeatedly)Fire alarm triggered
Red LED flashes 1× per second, no soundTemporary alarm silencing active (using the TEST/Silence button or the IR remote control – SIC technology)
Red LED flashes 2× every 60 sDevice fault – the alarm is not functional, clean it and test it (see Maintenance)
Red LED flashes 1× every 60 s + buzzer beeps 1× every 60 s (for 30 days)Low battery – end of life is approaching; the alarm must be replaced with a new one
The fire alarm can be temporarily silenced for approx. 9 minutes by pressing the button TEST/Silence, or by pressing any button on an ordinary IR remote control (SIC technology). After this time, the alarm returns to alarm mode if the smoke concentration has not dropped below the threshold value.

Choosing the installation location

Smoke alarms should ideally be installed in all rooms of the house except kitchens, bathrooms and garages. At least one alarm should be placed on every floor of the house, including the staircase. Place the alarms where you can hear them even when asleep – for example in the hallway in front of the bedroom. Install an alarm on the ceiling of each bedroom and in the hallway in front of the bedroom.

Recommended placement of fire alarms in the house by individual rooms and floors
Recommended placement of fire alarms (Figure 4-2-1)

Where not to install the alarm

  1. In bathrooms and kitchens – water vapour and steam from food can trigger a false alarm.
  2. In a garage – the alarm could react to exhaust fumes from vehicles.
  3. In places where the ventilation openings around the alarm are not freely accessible – do not cover them or otherwise seal them.
  4. Do not use aerosol products near the alarm.
National regulations may differ with regard to the number and placement of smoke alarms (see the standard EN 14604). In case of doubt, contact, for example, the fire and rescue service.

Ceiling or wall installation

The manufacturer allows the device to be installed both on the ceiling and on a side wall, the preferred mounting location being central installation on the ceiling. When installing on the ceiling, install the alarm at a distance of at least 500 mm from the corners of the room. When mounting on a side wall, position the device so that its upper part is at least 100 mm and at most 305 mm below the ceiling level.

Ceiling or side wall installation location – minimum and maximum distances
Installation location (Figure 4-2-2)

Installation on a sloping ceiling

If the ceiling slope is less than 45°, a suitable distance from the apex is at least 500 mm. If the slope is greater than 45°, a wooden base must be installed (not included in the package).

Installation location on a sloping ceiling – a wooden base is required for a slope above 45°
Installation location on a sloping ceiling (Figure 4-2-3)

Installing the alarm

Installation must be carried out by a competent person who is responsible for installing the device in accordance with applicable regulations. In case of doubt, turn to qualified professionals for installation or contact our technical support.
  1. Choose a suitable location for installing the fire alarm (see Choosing the installation location).
  2. At the installation location, drill holes (⌀ 6 mm) using the mounting bracket. Insert wall plugs into the prepared holes.
  3. Fix the bracket with self-tapping screws.
Mounting the mounting bracket – drilling holes, wall plugs, self-tapping screws and sticking on the information label
Mounting the bracket (Figure 4-3-1)
  1. Stick the information label in your language (“CAUTION! – Battery is not replaceable, see user manual”) on the device.
  2. Insert the alarm into the mounting bracket and turn it clockwise until it locks into position.
Fitting the alarm into the mounting bracket by turning it clockwise
Fitting the alarm into the bracket (Figure 4-3)
Once the alarm is locked into the mounting bracket, it activates automatically. This state is indicated by a short beep of the buzzer and a green flash of the LED indicator. The device then initialises for several seconds and automatically switches to standby mode (green LED flashes 1× every 60 s). If you need to remove the alarm from the bracket, turn the device anticlockwise.

Function test and Silence

After installing the device, or during its regular maintenance, an alarm test must be carried out to prove its functionality.

  1. Briefly press the button TEST/Silence.
  2. The buzzer sounds an acoustic tone and the LED indicator flashes red; a pause follows, then the buzzer beeps 3 times in a row accompanied by a flash of the red LED indicator, another pause and one more repetition.
Simulate a fire alarm test by pressing the TEST/Silence button at least once a week, to verify that the device is functioning correctly.

As soon as the smoke concentration reaches a predetermined value, the alarm sounds. The acoustic signalling can be temporarily silenced if necessary for approx. 9 minutes:

If the concentration of smoke particles subsequently falls below the predetermined value, the alarm automatically returns to normal operating mode. Otherwise, after the silence time has elapsed, the alarm returns to alarm mode.

ProblemSolution
The alarm does not sound the buzzer during testingIf you are testing immediately after the first activation, wait a few seconds for the alarm to initialise. Make sure you have pressed the TEST/Silence button correctly.
The alarm chirps intermittentlyCheck that the device is correctly positioned (see Choosing the installation location) and carry out maintenance (see Maintenance).
The LED indicator flashes red and the buzzer beeps every 60 sThe alarm's battery is depleted – the built-in battery cannot be replaced; the alarm must be replaced with a new one.

If the device test is not completed successfully, send the alarm in for a warranty claim.

Maintenance

End of life

The battery of the SAFE 10Y30-PRO alarm is built in and not user-replaceable. The alarm must be replaced with a new one after 10 years from the date of installation – the replacement date is shown on the information label on the back of the alarm. The alarm signals that its end of life is approaching (decline in battery capacity) by flashing the red LED indicator once accompanied by one beep of the buzzer at regular 60-second intervals for 30 days before the battery is fully depleted.

Do not attempt to remove or replace the battery inside the alarm. When its life has expired, replace the whole alarm with a new one. Do not dispose of the end-of-life device in municipal waste or throw it into a fire – hand it in for recycling in the electrical equipment take-back system.

Technical specifications

Detection parameters
Detection typeSmoke, fault, low battery capacity
SensorPhotoelectric – dual-spectrum (blue + IR LED)
MicroprocessorAI SAFE with predictive algorithm
Preset alarm value0.2–0.3 dB/m
Detection area20–40 m² (for a room height up to 8 m)
Protection against false alarmsYes (AI SAFE predictive algorithm)
Signalling
Acoustic85 dB at a distance of 3 m
VisualLED indicator (dual)
Silence functionYes – TEST/Silence button, IR remote control (SIC technology)
Silence timeapprox. 9 min
General
Order codeSAFE 10Y30-PRO
EAN code0703123017923
Power supply3 V DC, 1× CR123A lithium battery (integrated, non-replaceable)
Current consumptionStandby mode ≤ 15 µA; in alarm ≤ 35 mA
Battery / device life10 years
PCB protectionIZOVAX insulating and protective varnish layer with nanoparticles
Operating temperature−10 °C to +55 °C
Operating humidityup to 95 % RH (non-condensing)
Storage temperature / humidity−20 °C to +60 °C, 5–95 % RH (non-condensing)
Dimensions⌀ 81.5 mm × height 51.6 mm (with mounting bracket)
Weight110 g (with battery)
Mounting methodOn a ceiling or wall (mounting material included in the package)
Type of installationIndoor
CertificationEN 14604:2005+AC:2008; CE 1008-CPR-MC 69267856; ISO 7731; AS 3786:2014+A1+A2
Warranty10 years (on the device and battery)

Package contents

  1. Smoke alarm – 1 pc
  2. Self-tapping screw – 2 pcs
  3. Wall plugs – 2 pcs
  4. Mounting bracket – 1 pc
  5. User manual with a set of information labels – 1 pc

Safety notices

What to do in the event of a fire alarm

We recommend having a working fire extinguisher on every floor of the house, in the kitchen, the basement and the garage, drawing up an evacuation plan of the building with at least two escape routes, and carrying out a fire drill with evacuation practice at least once every six months, including at night.

Warranty

The manufacturer provides a warranty on the SAFE 10Y30-PRO alarm 10 years from the date of sale, covering both the device and the integrated battery. Under the warranty, the manufacturer's obligation is limited to repairing or replacing the alarm, or any part of it, in which a defect in material or workmanship is found.

The warranty becomes void if the product has been damaged, altered, misused or modified after purchase, or if it has stopped working as a result of poor maintenance or incorrect placement. The warranty does not affect your statutory rights.

In case of problems with the device, first contact technical support – most situations can be resolved remotely.

Need help?

SAFE HOME europe technical support:
E-mail: info@safe-home.eu  · Telephone: (+420) 581 222 262
Web: www.smart-safe.eu