FireSAFE / Standalone products

Standalone carbon monoxide (CO) alarm
SAFE 10YDCO-PRO

User manual

Updated 20 October 2026

Product page Datasheet (PDF)
The SAFE 10YDCO-PRO detector

SAFE 10YDCO-PRO is a new generation of standalone carbon monoxide detector with breakthrough detection using a second-generation electrochemical sensor and a colour LCD display with environmental functions. Power is supplied by an integrated lithium battery (built in, non-replaceable) guaranteeing exceptionally long operation of the device of more than 10 years and an extended 10-year warranty on both the battery and the device itself. The SAFE 10YDCO-PRO carbon monoxide (CO) detector sets a new level of standard in the fire safety of residential buildings.

10 yearsoperation on the integrated battery
85 dBCO acoustic alarm
30 ppmsensor sensitivity from
9 minalarm silence time
Type Bfixed and portable installation
10 yearswarranty on the device and battery
COElectrochemical carbon monoxide (CO) sensor
Environmental functions – temperature and humidity display
Multifunction backlit LCD display
10 years of battery operation
IZOVAX protection
Design allowing free-standing installation
EN 50291-1 certification and extended warranty

Foreword

General

This user manual describes the installation, functions and operation of the SAFE 10YDCO-PRO standalone carbon monoxide detector (hereinafter the “detector” or “device”). The detector works completely independently, with no need to connect to a Hub or mobile app. Read this manual carefully and keep it safe for future reference and for any subsequent user.

In this user manual, alongside the name “carbon monoxide” we will also repeatedly use the abbreviation “CO”.

Safety instructions

The following signal words may appear in the user manual:

Signal wordMeaning
NEBEZPEČÍIndicates a high potential hazard which, if not avoided, may result in death or serious injury.
VAROVÁNÍIndicates a medium or low potential hazard which, if not avoided, could result in minor or moderate injury.
UPOZORNĚNÍIndicates a potential risk which could lead to property damage, data loss, reduced performance or an unpredictable result.
TIPProvides methods to help you solve a problem or save time.
POZNÁMKAProvides additional information, such as emphasis or a supplement to the text.

Revision history

VersionRevision contentRelease date
V1.0.0First release.September 2026
V1.0.1Colours according to the FireSAFE brand (red).October 2026
V1.0.2Technical specifications corrected according to the manufacturer's documents.October 2026

About the manual

Operating requirements

VAROVÁNÍ
UPOZORNĚNÍ

Installation requirements

VAROVÁNÍ
UPOZORNĚNÍ

What to do in the event of a CO alarm

If the detector detects a dangerous concentration of carbon monoxide, it sounds a loud alarm signal (85 dB) accompanied by a visual indication from the red LED indicator: every 5 seconds 4 short beeps of the buzzer accompanied simultaneously by 4 flashes of the red LED indicator at regularly repeating intervals, while the blue-backlit display of the detector shows the current measured CO concentration in ppm.

By sounding the alarm, the detector warns of the presence of carbon monoxide (CO), which can cause death. If the CO detector alarm sounds, we recommend that you:
  • Stay calm and open all doors and windows. Stop using all fuel-burning appliances and, if possible, make sure they are switched off (e.g. close the emergency valve on gas appliances).
  • Press the button TEST/Silence to temporarily silence the alarm (for 9 minutes). If the warning signal persists, inform the other occupants and evacuate the building – leave the doors and windows open and do not return to the premises.
  • Obtain medical help for anyone suffering from symptoms of CO poisoning (headache, nausea) and tell the doctor that carbon monoxide inhalation is suspected.
  • Call the emergency number 112, the gas supplier on its emergency number, or the appliance service organisation. Make sure the source of the CO leak is identified and eliminated.
External conditions (e.g. heavy air pollution from road traffic in cold weather) can affect CO detectors – in such cases, opening doors and windows may actually increase the amount of CO.

If the area is ventilated after the alarm has sounded, the carbon monoxide may disperse before help arrives. Even in that case, it is necessary to identify the source of the CO leak and have its cause eliminated. Do not start using any fuel-burning appliances again until they have been checked and cleaned by a competent person in accordance with national regulations.

Never ignore the alarm signal of a CO detector! A high concentration of CO can quickly lead to a dangerous situation.

Time to alarm as a function of CO concentration

CO concentrationTime to alarm
30 ppm120 min
50 ppm60 to 90 min
100 ppm10 to 40 min
300 ppmwithin 3 min

About carbon monoxide (CO)

What is carbon monoxide

Carbon monoxide is the main gaseous product of combustion, formed during incomplete (uncontrolled) burning of carbon-based materials. It is a colourless, non-irritating gas with no taste or smell, whose toxic effects impair the blood's ability to carry oxygen. Exposure to a high concentration of CO can lead to serious tissue damage or have fatal consequences. The severity of CO inhalation poisoning depends on the concentration (ppm) and the length of exposure – CO is a cumulative poison, and long-term exposure to low concentrations (>10 ppm) can also cause symptoms.

CO concentration (ppm)Effects on adults
100 ppmMild headache, nausea, fatigue (flu-like symptoms)
200 ppmDizziness and headache within 2–3 hours
300 ppmNausea, headaches in the temples and forehead, drowsiness, disorientation and rapid heartbeat; life-threatening after more than 3 hours of exposure
400 ppmSevere headaches, convulsions, failure of vital organs; death may occur within 2–3 hours
  • This device may not prevent the effects of continuous exposure to carbon monoxide and will not fully protect individuals with specific medical conditions.
  • The device detects only carbon monoxide (CO); it does not detect other gases, smoke or flame. If there is any doubt about the cause of the signalling, a dangerous CO level is assumed and the occupants should be evacuated.

Possible sources of carbon monoxide

CO is produced by the incomplete combustion of carbon-based fuels (coal, wood, charcoal, heating oil, paraffin, petrol, propane, butane, natural gas).

Basic steps to protect against CO poisoning

Functional elements

The SAFE 10YDCO-PRO detector from the front (buzzer, LCD display, LED indicator, TEST/Silence button) and from the back (battery location, blocking clip, deactivation port and pin)
Functional elements of the SAFE 10YDCO-PRO detector
  1. Buzzer – provides acoustic information (85 dB) on the states of the device's individual modes, accompanied by visual signalling from the LED indicator.
  2. LCD display – multifunction, shows the current CO concentration (ppm), temperature and humidity, or the highest measured value.
  3. LED indicator – provides visual information via a three-colour LED indicator (red = alarm, green = power, yellow = fault).
  4. TEST/Silence button – verifies the functionality of the device and is used to temporarily silence the acoustic alarm signal, recall the memory of the highest measured values and reset.
  5. Battery location – built-in battery, not user-replaceable.
  6. Blocking clip – removing it activates the device's built-in battery.
  7. Deactivation port – port for inserting the deactivation pin.
  8. Deactivation pin – for permanent deactivation of the built-in battery (before the device is disposed of).

Principle of operation

The detector is designed for continuous monitoring, detection and signalling of the presence of carbon monoxide (CO) in residential areas. To detect CO it uses advanced second-generation electrochemical sensor technology with high sensitivity and stable performance, capable of detecting even very low concentrations of CO (from 30 ppm). Throughout its service life (more than 10 years) the sensor requires no further calibration. The detector is controlled by an AI SAFE microprocessor and signals danger both visually and acoustically.

Device Type B is intended for both fixed and portable installations and is certified in accordance with the European standards EN 50291-1:2018 and EN 50291-1:2018/AC:2021 for carbon monoxide detectors.

LCD display description

The backlit multifunction LCD display shows information depending on the current ambient conditions:

The temperature can be displayed in degrees Celsius (°C) or Fahrenheit (°F). To switch between °C and °F, press the TEST/Silence button while the temperature is displayed in active test mode.

Temporary alarm silencing

If the detector detects the threshold CO concentration level, it triggers the warning signal. In the event of a false alarm, the acoustic signal can be temporarily silenced by pressing the button TEST/Silence for 9 minutes (this can be activated only when the CO concentration is below 300 ppm). Temporary silence mode is indicated by the red LED indicator (alarm), which flashes 4 times every 5 seconds without an accompanying buzzer sound. If the CO concentration subsequently falls below the specified value, the detector automatically returns to normal operating mode.

Highest-reading memory

The detector has a highest-reading memory function. Pressing and holding the TEST/Silence button recalls on the LCD display the highest measured values since the last memory reset. To manually reset the device and the memory, press and hold the TEST/Silence button in test mode.

Do not manually reset the device before the source of the carbon monoxide has been identified and remedial action has been taken.

Signalling

ModeLED indicatorBuzzer / display
ActivationNo signallingNo signalling; the LCD backlight comes on for 3 s
Standby modeGreen LED (POWER) 1× every 60 sNo signalling; the display alternately shows temperature and humidity
Alarm modeRed LED (alarm) 4 flashes every 5 s4 short beeps of the buzzer every 5 s; the display shows the CO concentration in ppm
Test mode6 flashes (green, yellow, red, 2×), pause, repeat4 short beeps, pause, 4 short beeps, ending with 1 beep
Highest-reading modeGreen LED (POWER) 4 flashes every 5 sShort beep every 3 s
Temporary silenceRed LED (alarm) 4 flashes every 5 sNo signalling
Low battery voltageYellow LED (FAULT) 1 flash every 60 s1 short beep every 60 s, for 30 days
FaultYellow LED (FAULT) 2 flashes every 60 s1 short beep every 60 s
End-of-life signallingYellow LED (FAULT) 3 flashes every 60 s3 short beeps every 60 s, for 30 days
In the event of an alarm or temporary silence, the current CO concentration in ppm can be read on the LCD display. For the detailed procedure, see What to do in the event of a CO alarm.

Choosing the installation location

CO detectors should ideally be installed in all rooms containing a fuel-burning appliance. We strongly recommend installing additional detectors in bedrooms and in rooms where you spend a lot of time during the day – in places where you will hear the signal even when asleep (e.g. on the bedside table in a bedroom).

Recommended placement of CO detectors in a house – basic and optimal protection
Recommended placement of CO detectors (Figure 6.2)

Which rooms to install in

Install a detector in every room containing a fuel-burning appliance as a priority. Install further devices so that the signal is audible to occupants of remote rooms (living rooms, all bedrooms) as well. If there are several appliances and the number of detectors is limited, consider:

Where in the room to install

A room with a fuel-burning appliance (stove, boiler, gas fireplace, fireplace): CO rises with the warm mixture of gases, so install the detector above the level of the appliance and close to the ceiling:

Installation in a room with a fuel-burning appliance – minimum and maximum distances from the ceiling and the CO source
Installation in a room with a fuel-burning appliance (Figure 6.2.3)

Bedrooms or rooms remote from the appliance (corridors, landings): install the detector on the wall at a height of 1,5–1,6 m above the floor, near the users' breathing zone. Never install the detector at floor level – carbon monoxide is lighter than air and only rarely settles near the floor.

Thanks to its free-standing design, the detector can also be placed on a horizontal surface (shelf, bedside table, windowsill) in accordance with the height recommendations above. Owing to the unique design of the device, fixed installation on a ceiling is not recommended – if incorrectly mounted, it could come loose, fall and injure people. The device is not intended for use in caravans, motorhomes or on boats.

Where not to install the detector

Installing the detector

This device must be installed by a competent person in accordance with the manufacturer's instructions. If in doubt, contact qualified professionals for the installation or contact our technical support.

The SAFE 10YDCO-PRO detector can be installed in two ways – fixed wall mounting, or free-standing on a horizontal surface thanks to the two stabilising feet on the base of the device.

Wall mounting

  1. Following the chapter Choosing the installation location select a suitable location.
  2. Using the supplied drilling template, drill holes (⌀ 5 mm) at the installation location and insert wall plugs into them.
Using the drilling template and a wall plug in holes 5 mm in diameter
Using the drilling template (Figure 6.3.1)
  1. Insert self-tapping screws into the wall plugs and tighten them so that a gap of approx. 5 mm remains between the screw head and the wall.
  2. From the set of information labels, stick labels A and B onto the front of the device and label C onto the back, all in the required language.
  3. Activate the CO detector by pulling out the blocking clip on the back of the device. Keep the blocking clip – it can be reused to temporarily interrupt the power, for example when moving house, to prevent the alarm from being triggered accidentally.
  4. Place the CO detector, back first, onto the heads of the self-tapping screws and slide it downwards so that the screw heads engage in the locking position of the openings in the detector.
  5. After installation, test the functionality of the device by pressing the TEST/Silence button – check that the LED indicators, buzzer and LCD display are working correctly (see Function test and Silence).

Free-standing installation on a horizontal surface

The design of the detector base has two stylish feet that allow flexible and stable free-standing installation on a horizontal surface.

Detector base design with feet for flexible and stable free-standing installation
Base / feet design (Figure 6.3.2)
  • For free-standing installation, the detector must be placed in an upright position – it must not be laid flat on a horizontal surface.
  • Place it so that there is no risk of it being knocked over, falling or being otherwise damaged.
  • Even for free-standing installation, observe the recommended placement described in the chapter Choosing the installation location.

Function test and Silence

After installing the device, or during its regular maintenance, a CO detector test must be carried out to prove its functionality.

  1. Briefly press the button TEST/Silence – the blue backlight of the LCD display comes on for 5 seconds.
  2. While the display is backlit, press the TEST/Silence button again – the device activates test mode.
  3. The display alternately shows information icons together with the current CO concentration, the last highest measured value, temperature and humidity; the buzzer sounds 4 short beeps accompanied by 6 flashes of the LED indicator (green, yellow, red, 2×), pause, repeat, ending with 1 beep of the buzzer and a flash of the red LED.
Simulate a carbon monoxide alarm test regularly, at least once a week by pressing the TEST/Silence button, to verify that the device is functioning correctly.

In the event of a false alarm or if necessary, the acoustic signal can be temporarily silenced by pressing the button TEST/Silence for 9 minutes (this function can be activated only when the CO concentration is below 300 ppm). If the CO concentration subsequently falls below the specified value, the detector automatically returns to normal operating mode; otherwise, after the silence time has elapsed, it returns to alarm mode.

If the device test is not completed successfully, send it in for a warranty claim.

Maintenance

End of life

The battery of the SAFE 10YDCO-PRO detector is built in and not user-replaceable. The detector must be replaced with a new one after 10 years from the date of installation – the replacement date is shown on the information label on the back of the device. The detector signals that its end of life is approaching by flashing the yellow LED indicator (FAULT) 3 times, accompanied by 3 beeps of the buzzer, at regular 60-second intervals for 30 days.

Before the device is disposed of at the end of its life, the built-in battery must be deactivated:
  1. Tear off information label C on the back of the device and use a flat screwdriver to remove the deactivation pin.
  2. Insert the pin into the deactivation port, push and turn it. If the LCD display stops showing any information, the built-in battery has been deactivated successfully.
Do not dispose of the end-of-life device in municipal waste or throw it into a fire – hand it in for recycling in the electrical equipment take-back system.

Technical specifications

Detection parameters
Detected gasCarbon monoxide (CO)
SensorElectrochemical CO sensor, 2nd generation
MicroprocessorAI SAFE with predictive algorithm
Device typeB (fixed and portable installation)
CalibrationNot required during the service life of the sensor
Temperature measurement accuracy±0,1 °C
Humidity measurement accuracy±1.5 % RH
Signalling
Acoustic≥ 85 dB at a distance of 3 m
VisualThree-colour LED indicator (green = power, yellow = fault, red = alarm) + backlit LCD display
Silence functionYes – TEST/Silence button
Silence time9 min
Highest-reading memoryYes
General
Order codeSAFE 10YDCO-PRO
EAN code0703123018210
Power supply3 V DC, 1× CR17450A lithium battery (integrated, non-replaceable)
Current consumptionStandby mode ≤ 20 µA; in alarm ≤ 20 mA
Battery / device life10 years
Operating temperature−10 °C to +55 °C
Operating humidityup to 95 % RH (non-condensing)
Storage temperature / humidity−20 °C to +60 °C, 5–95 % RH (non-condensing)
Dimensions133.5 × 63.5 × 28.9 mm
Weight122 g (with battery)
Package dimensions / weight45 × 80 × 135 mm, 193 g
Carton540 × 430 × 335 mm, 96 pcs, 20.1 kg
Mounting methodOn a wall, or free-standing on a horizontal surface
Type of installationIndoor
Degree of protectionIP30
CertificationEN 50291-1:2018; EN 50291-1:2018/AC:2021; BS EN 50291-1:2018; certificate No. R 50607144 0001
Warranty10 years (on the device and battery)

Package contents

  1. CO detector – 1 pc
  2. Drilling template – 1 pc
  3. Self-tapping screws – 2 pcs
  4. Wall plugs – 2 pcs
  5. User manual with a set of information labels – 1 pc

Safety notices

Warranty

The manufacturer provides a warranty on the SAFE 10YDCO-PRO detector 10 years from the date of sale, covering both the device and the integrated battery. Under the warranty, the manufacturer's obligation is limited to repairing or replacing the detector, or any part of it, in which a defect in material or workmanship is found.

The warranty becomes void if the product has been damaged, altered, misused or modified after purchase, or if it has stopped working as a result of poor maintenance or incorrect placement. The warranty does not affect your statutory rights.

In case of problems with the device, first contact technical support – most situations can be resolved remotely.

Need help?

SAFE HOME europe technical support:
E-mail: info@safe-home.eu  · Telephone: (+420) 581 222 262
Web: www.smart-safe.eu