Keypad Plus is a wireless, backlit touch keypad that allows simple control of the security system using touch keys or encrypted contactless chips. In an emergency, it can also trigger a panic alarm, fire alarm, or medical assistance alarm. The keypad features password-guessing protection, which automatically locks the keypad after several unsuccessful code entry attempts. Current status information of the security system can then be indicated via the individual LED indicators.
Preface
General
This user manual describes the installation, functions, and operation of the wireless keypad with RFID reader (hereinafter the "keypad"). Before using the device, read this manual carefully and keep it for future reference.
Safety Instructions
The following signal words may appear in the user manual:
| Signal Word | Meaning |
|---|---|
| DANGER | Indicates a high potential hazard that, if not avoided, may result in death or serious injury. |
| WARNING | Indicates a medium or low potential hazard that could cause minor or moderate injury if not avoided. |
| CAUTION | Indicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome. |
| TIP | Provides methods to help you solve a problem or save time. |
| NOTE | Provides additional information, such as emphasis and supplementary text. |
Revision History
| Version | Revision Content | Release Date |
|---|---|---|
| V1.0.0 | First release. | August 2026 |
Privacy Notice
As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.
About the Manual
- The user manual serves as a reference guide only. There may be minor differences between the information provided and the product.
- We are not liable for any damage resulting from using the product in a manner that does not comply with the instructions in the user manual.
- The manual will be updated according to the latest laws and regulations of the relevant jurisdictions. For detailed information, refer to the printed user manual, scan the QR code, or visit our official website. The manual is for reference purposes only. There may be minor differences between the electronic and paper versions.
- All designs and software are subject to change without prior written notice. Due to product updates, certain differences may occur between the product and the information in the manual. Customer service will provide you with the latest version of the software and supplementary documentation.
- There may be printing errors or discrepancies in the description of functions, operations, and technical data. In the event of doubt or dispute, we reserve the right of final explanation. If the manual (in PDF format) cannot be opened, update your reader software or try a different common reader software.
- All trademarks, registered trademarks, and company names in the manual are the property of their respective owners.
- If you encounter any problems while using the device, visit our website or contact your supplier or customer service.
- In the event of ambiguity or dispute, we reserve the right of final explanation.
Important Safeguards and Warnings
This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.
Operating Requirements
- Before use, make sure the device's power supply is working properly.
- Do not unplug the device's power cable while it is switched on.
- Use the device only within its rated power range.
- Transport, use, and store the device within the permitted humidity and temperature conditions.
- Prevent liquids from splashing or dripping onto the device. Make sure there are no liquid-filled objects on the device, to prevent liquid from entering it.
- Do not disassemble the device.
Installation Requirements
- Before switching on, connect the device to the power adapter.
- Strictly comply with local electrical safety standards and make sure the voltage in the area is stable and matches the device's power requirements.
- Do not connect the device to more than one power source. Otherwise, the device could be damaged.
- When working at heights, follow all safety procedures and use the required protective equipment.
- Do not expose the device to direct sunlight or heat sources.
- Do not install the device in damp, dusty, or smoky locations.
- Install the device in a well-ventilated location and do not block its ventilation.
- Use the power adapter or power supply provided by the device manufacturer.
- The power supply must meet the ES1 requirements of IEC 62368-1 and must not exceed PS2. The power supply requirements are governed by the device's rating label.
- Connect Class I electrical appliances to a socket with protective earthing.
Functional Elements
- Indicator – four LEDs (communication, arm/disarm, fault, alarm).
- Keypad buttons – 15 touch keys (0–9, *, #, arm, home arm, disarm).
- RFID card reader – area for presenting a contactless card or key fob.
- Rear cover – opening it triggers a tamper alarm.
- Power switch – turns the keypad on and off.
- Battery compartment – 4× AA batteries.
- Tamper contact – triggers an alarm when the keypad is removed from the mounting plate.
The top row of icons above the numeric keypad shows a status matching the LED indicators (communication, arm/disarm, fault, alarm). The numeric keys 1, 2 and 3 also serve as panic shortcuts – fire alarm, panic alarm (SOS), and medical assistance call. Below the "0" key are three keys for Home Armed (house icon), Arm (shield icon), and Disarm (crossed-out shield icon), and an icon marking the card reader area.
Operating Principle
Keypad Plus allows you to control the SAFE security system by entering a personal access code on the touch keypad, or by presenting an encrypted contactless RFID card (Mifare 13.56 MHz) to the reader. Each keypad user has their own access code and set of cards, and the system records who made a particular status change and when.
SAFE Keeper protocol
Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:
- AES-128 encryption with a rolling code,
- frequency hopping as protection against interference,
- range up to 1 600 m in open space,
- regular connection check – the system immediately reports a keypad outage.
Waking the keypad
The keypad conserves battery power, so it goes to sleep on its own after a period of inactivity:
- Hold any key for more than 0.1 s – a short beep sounds and all LED indicators light up; the keypad is ready for use.
- If you do not use the keypad for more than 4 s, the key backlight dims.
- If you do not use the keypad for more than 12 s, it beeps twice, all LEDs turn off, and the keypad goes into sleep mode.
- If the keypad is offline, after waking only the communication indicator blinks slowly green; the other indicators remain off.
Password-guessing protection
After the set number of incorrect code entry attempts within 30 minutes, the keypad temporarily locks (see Settings) – this prevents systematic code guessing.
Duress code
In addition to the regular access code, each user can optionally also be assigned a duress code. If a user is forced to enter their code under duress, they enter the duress code instead of the regular one – the system outwardly evaluates the code as valid and operates the keypad normally, but at the same time silently triggers a duress alarm and alerts the operator without the attacker noticing.
Integrated temperature sensor
The keypad measures the ambient temperature in the range of −15 °C to +65 °C with an accuracy of ±1 °C and allows an alarm to be set when the selected temperature range is exceeded.
Adding to the System
Before adding the device
- Install the app ProSAFE and log in to your account.
- Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
- The hub must be in the Disarmed state.
How to add the Keypad Plus keypad
- In the ProSAFE app, open your hub and click Device.
- Click + Add device.
- Scan the QR code with the serial number on the back of the keypad and follow the instructions.
- Insert the batteries and turn on the keypad using the power switch to the ON.
- Wait for pairing to complete – successful pairing is confirmed by the communication LED lighting up for 2 seconds.
- Enter the keypad name, select the area (zone), and click Done.
User management
Keypad users can only be added, edited, or deleted while the system is the Disarmed state. Only the installer and administrator are authorized to add users.
- On the home screen, select the hub and go to Device Details → Hub Settings → User Management.
- Click the icon to add a user.
- Enter the user's name, access code, optionally duress code, and select the arm and disarm permissions for individual areas.
- Click Save.
Editing and removing a user
- Removing a user – on the User Management screen, select the user and swipe left. The administrator must be the last one removed from the keypad.
- Editing user details – on the User Management screen, select the user and edit the name, access code, duress code, or arm/disarm permissions.
Adding RFID cards
Cards can only be added, edited, or deleted while the keypad is the Disarmed state. Only the installer and administrator are authorized to add cards. A card can be added to the keypad in two ways.
Adding a card in User Management
- On the home screen, select the hub and go to Device Details → Hub Settings → User Management.
- Select the user to whom you want to assign the card.
- Click the icon to add a card.
- Press any key to wake the keypad, and within 30 seconds present the card to the card reader area – the keypad will then enter card issuing mode.
- If the card is successfully recognized, its ID is displayed in the app and the keypad beeps once. After saving the configuration, the card receives the assigned user's permissions.
Adding a card in the Devices list
- On the hub screen, select Device.
- Click the add icon and select Add card.
- Press any key to wake the keypad.
- Present the card to the card reader area – the keypad enters card issuing mode.
- On the Linked User screen, choose whether to assign the card to an existing user or create a new one (see User management).
- Click Done.
Control
| Command | Procedure |
|---|---|
| Global arm | Access code + Arm + # |
| Global home arm | Access code + Home Armed + # |
| Global disarm | Access code + Disarm + # |
| Arm one area | Access code + * + area no. area + Arm + # |
| Home arm one area | Access code + * + area no. area + Home Armed + # |
| Disarm one area | Access code + * + area no. area + Disarm + # |
| Check area status | Access code + * + area no. area + # |
| Cancel entry | Hold the # key |
| Panic alarm (SOS) | Hold the 2 key for 3 s |
| Fire alarm | Hold the 1 key for 3 s |
| Medical assistance call | Hold the 3 key for 3 s |
| Control by card | Present the RFID card to the reader |
States
You can view the current keypad status in the ProSAFE app by selecting the keypad in the Devices list.
| Parameter | Meaning |
|---|---|
| Temporarily disable | Keypad function status
|
| Temperature | Current ambient temperature measured by the integrated sensor |
| Signal strength | Radio signal level: none / low / weak / good / excellent |
| Input voltage | Keypad power supply voltage value |
| Battery level | Full / sufficient / medium / insufficient / low |
| Tamper status | Indicates that the keypad has been removed from the mounting plate |
| Online status | Connection between the keypad and hub – online / offline |
| Lock status | The keypad is locked / unlocked (see Password-Guessing Protection) |
| Transmission via repeater | Whether the keypad communicates with the hub via a signal repeater |
| Firmware version | Current keypad firmware version |
Settings
You can change the settings in the ProSAFE app: select the keypad in the Devices list and click the edit icon.
| Settings | Value |
|---|---|
| Device name | Custom keypad name; displayed in the Devices list and in notifications |
| Area (zone) | Assignment of the keypad to a system area |
| Control permissions | Determines which areas the keypad can control |
| Temporarily disable | Allow (default) / Disable tamper alarm only / Disable |
| Keypad control | Enabling panic shortcuts and their siren signaling
|
| Keypad lock | Password-guessing protection
|
| Transmission power | High / low / automatic – higher power increases range and consumption; at low power the indicator blinks (reduced sensitivity mode) |
| Card reader settings | Card reader – turns card recognition on/off (default on) Software encryption – encrypts card data when issuing (default on) |
| Backlight brightness | Off / low / high – brightness is automatically reduced when the battery level is low |
| Entry/exit delay and arm/disarm tone | When enabled, the keypad buzzer accompanies the ongoing delay with a countdown
|
| Buzzer volume | Off / low / high |
| Unusual temperature alarm | Alarm when the set temperature range (min/max) is exceeded |
| Signal strength detection | Verification of radio connection quality at the installation site – unavailable in sleep mode; first wake the keypad by pressing a key |
| Cloud update | Remote firmware update |
| Remove device | Deleting the keypad from the system (swipe left in the Devices list) |
Signaling
Status LED indicators
| Indicator | LED indication | Event |
|---|---|---|
| Communication | Fast green blinking | Pairing mode |
| Lights up green for 2 s | Successful pairing with the hub | |
| 3× flashes green | Pairing failed | |
| Off | The keypad is online | |
| Slow green flashing, other LEDs off | The keypad is offline | |
| Slow green flashing, other LEDs in normal state | Reduced sensitivity mode (low transmission power) | |
| Arm/disarm | Steady blue light | One or more areas are armed |
| 3× slow green flashing, then off | All areas are disarmed | |
| Fault | Flashes yellow | A fault message has been triggered |
| Off | The system is armed, or there are no faults | |
| Alarm | Flashes red | An alarm has been triggered |
| All 4 LEDs | Steady light for 2 s | Keypad power-on |
Audible and visual command response
| Response | Meaning |
|---|---|
| 3× slow green flash and off + 2 short beeps | Successful disarm (both global and single area) |
| 3× slow blue flash, then steady light + 1 short beep | Successful arm |
| 2× fast green flash, then return to normal + 1 long beep | Arming failed due to a fault – repeating the same command within 30 s (or presenting the same card within 10 s) allows a forced arm to be performed |
| 2× fast backlight flash + 1 long beep | Incorrect code, invalid card, or user without permission |
| 1 beep, LED according to area status | Successful status check – blue for 6 s (armed), 3× slow green flashing (disarmed), fault LED for 6 s (fault), alarm LED for 6 s (alarm) |
| 3× fast backlight flash + 1 long beep | Status check failed – incorrect code, invalid card, or query for an area not assigned to the card |
Keypad installation
The keypad is wall-mounted. Before drilling, we recommend adding the keypad to the system and testing the signal strength at the intended installation site (see Adding to the System).
- Loosen the screw on the bottom of the cover.
- Open the cover by moving it in the direction of the arrow.
- Insert 4 AA batteries, observing the correct polarity. Turn on the device using the power switch and close the rear cover.
- Drill 4 holes in the wall according to the hole positions on the rear cover and insert the wall plugs.
- Attach the rear cover to the wall using suitable fasteners.
- Fit the keypad body onto the rear cover by sliding it in the direction of the arrow.
- Close the keypad cover and secure it by tightening the screw (tightening torque 0.5–0.8 N·m).
Functionality Test
After installation, verify that the keypad functions correctly:
- Signal strength detection – run a test in the app and verify that the signal reaches at least 2 bars. The keypad must first be woken by pressing any key before the test.
- Access code test – enter the code and perform both arming and disarming, verifying the correct LED and audible response.
- RFID card test – present the card to the reader and verify that the keypad beeps and the corresponding event appears in the app.
- Panic shortcut test – hold key 1, 2, or 3 for 3 s and verify that the corresponding alarm appears in the app and that any linked siren is triggered.
- Keypad lock test – repeatedly enter an incorrect code and verify that the keypad locks after the set number of attempts.
Battery replacement
The keypad is powered by 4× AA batteries (1.5 H) with a lifespan of up to 3 years with one arm and disarm per day. If entry/exit delay signaling and the arm/disarm tone are enabled, battery life is shortened to approximately 2 years. The ProSAFE app will warn you of a low battery.
- Loosen the screw on the bottom of the cover and open the cover by moving it in the direction of the arrow.
- Remove the old batteries and insert 4 new AA batteries. Observe the correct polarity – the "+" symbols on the batteries must match the symbols in the keypad.
- Turn on the device using the power switch to the ON.
- Close the keypad cover and secure it by tightening the screw (0.5–0.8 N·m).
Maintenance
- Clean the keypad surface with a dry, soft cloth. Do not use aggressive or abrasive cleaning agents.
- Regularly check the battery status and signal strength in the ProSAFE app.
- Keep the keypad away from moisture, dust, and soot, and protect it from direct sunlight and heat sources.
- Do not disassemble the keypad beyond the procedure described in this manual.
- After replacing the batteries or relocating the keypad, verify the signal strength test.
Technical Specifications
| Interface | |
| Indication | 4× LEDs (communication, arm/disarm, fault, alarm) |
| Button | 1× power button |
| Buzzer | 1× built-in |
| Keypad buttons | 15× (0–9, *, #, arm, home arm, disarm) |
| Card reader | 1× contactless (RFID Mifare 13.56 MHz) |
| Function | |
| Arming and disarming | Access code, RFID card |
| Panic shortcuts | 3 (fire, SOS, medical assistance) |
| User management | Max. 32 users |
| RFID card | Max. 8 cards per user |
| Tamper contact | Yes (tamper) |
| Remote update | Yes (cloud) |
| Temperature sensor | Yes |
| Signal strength search / detection | Yes |
| Test mode | Yes |
| Low battery warning | Yes |
| Password-guessing protection | Yes (temporary keypad lockout) |
| Temperature sensor | |
| Measuring range | −15 °C to +65 °C |
| Accuracy / resolution | ±1 °C / 1 °C |
| Wireless transmission – SAFE Keeper | |
| Carrier frequency | 868,0–868,6 MHz |
| Transmitter power (EIRP) | limit 25 mW |
| Communication distance | Up to 1 600 m in open space |
| Communication type | Two-way |
| Encryption | AES128 |
| Frequency hopping | Yes |
| General | |
| Power supply | 4× AA batteries (included) |
| Power consumption | Max. 2.3 W |
| Current draw | ≤ 82,5 µA (operation) / ≤ 1 A (alarm) |
| Battery life | 3 years (1× arm/disarm daily); 2 years with entry/exit delay signaling and arm/disarm tone enabled |
| Operating temperature | −10 °C to +55 °C |
| Operating humidity | 10–90 % RH |
| Dimensions | 146,0 × 82,0 × 22,6 mm |
| Weight | 240 g (with battery) / 145 g (without battery); gross 370 g |
| Installation | Wall |
| Housing material | PC + ABS, white |
| Compatibility | Hub 2 Plus LTE (SAFE 38300) |
| Certification | CE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-3:2009; EN 50131-6:2017; EN 50131-5-3:2017; Security grade 2; Environmental class II |
Package Contents
- Keypad Plus keypad – 1 pcs
- AA batteries – 4 pcs
- Fasteners (screws, wall plugs) – 1 set
- RFID card – 2 pcs
- Quick user guide – 1 pcs
- Legal and regulatory information – 1 pcs
- QR code with the user manual – 1 pcs
Safety Notices
- Before use, check that the power supply is in order and operate the keypad only within the rated power supply range.
- Transport, use, and store the keypad only within the permitted temperature and humidity conditions.
- Protect the keypad from dripping and splashing liquid, and do not place containers filled with liquid on or near it.
- Do not place the keypad in locations exposed to direct sunlight or near heat sources, moisture, dust, or soot.
- Keep batteries out of reach of children. Do not dispose of them in fire or a hot oven, do not crush or cut them – risk of explosion. Do not leave batteries in an environment with extremely high temperature or expose them to extremely low air pressure – risk of explosion or leakage of flammable liquid and gas.
- If a battery is suspected to have been swallowed or to have entered the body, seek medical help immediately.
- Replace discharged batteries only with batteries of the same type and model.
- Do not dispose of the product with regular household waste – hand it in for recycling through the electrical equipment take-back system.
Warranty
The SAFE Keypad Plus device is covered by a warranty 36 months from the date of sale. The warranty does not cover batteries or defects caused by failure to follow the instructions in this manual.
If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.
Gallery
Need Help?
SAFE HOME europe technical support:
Email: info@safe-home.eu · Phone: (+420) 581 222 262
Website: www.smart-safe.eu