Door Guard is a wireless universal magnetic door/window contact for the SAFE security system, providing reliable protection for windows and doors of all types and designs. The device consists of two modules – the detector and the magnet – and is equipped with one NC/NO input for connecting an external wired device. The detector contains a highly reliable reed relay capable of up to 2 million opening cycles, and communicates with the SAFE system using an encrypted protocol SAFE Keeper at a distance of up to 1 200 m in open space.
Preface
General
This user manual describes the installation, functions, and operation of the wireless magnetic door/window contact (hereinafter the "detector"). Before using the device, read this manual carefully and keep it for future reference.
Safety Instructions
The following signal words may appear in the user manual:
| Signal Word | Meaning |
|---|---|
| DANGER | Indicates a high potential hazard that, if not avoided, may result in death or serious injury. |
| WARNING | Indicates a medium or low potential hazard that could cause minor or moderate injury if not avoided. |
| CAUTION | Indicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome. |
| TIP | Provides methods to help you solve a problem or save time. |
| NOTE | Provides additional information, such as emphasis and supplementary text. |
Revision History
| Version | Revision Content | Release Date |
|---|---|---|
| V1.0.0 | First release. | August 2026 |
Privacy Notice
As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.
About the Manual
- The user manual serves as a reference guide only. There may be minor differences between the information provided and the product.
- We are not liable for any damage resulting from using the product in a manner that does not comply with the instructions in the user manual.
- The manual will be updated according to the latest laws and regulations of the relevant jurisdictions. For detailed information, refer to the printed user manual, scan the QR code, or visit our official website. The manual is for reference purposes only. There may be minor differences between the electronic and paper versions.
- All designs and software are subject to change without prior written notice. Due to product updates, certain differences may occur between the product and the information in the manual. Customer service will provide you with the latest version of the software and supplementary documentation.
- There may be printing errors or discrepancies in the description of functions, operations, and technical data. In the event of doubt or dispute, we reserve the right of final explanation. If the manual (in PDF format) cannot be opened, update your reader software or try a different common reader software.
- All trademarks, registered trademarks, and company names in the manual are the property of their respective owners.
- If you encounter any problems while using the device, visit our website or contact your supplier or customer service.
- In the event of ambiguity or dispute, we reserve the right of final explanation.
Important Safeguards and Warnings
This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.
Operating Requirements
- Before use, make sure the device's power supply is working properly.
- Do not unplug the device's power cable while it is switched on.
- Use the device only within its rated power range.
- Transport, use, and store the device within the permitted humidity and temperature conditions.
- Prevent liquids from splashing or dripping onto the device. Make sure there are no liquid-filled objects on the device, to prevent liquid from entering it.
- Do not disassemble the device.
Installation Requirements
- Before switching on, connect the device to the power adapter.
- Strictly comply with local electrical safety standards and make sure the voltage in the area is stable and matches the device's power requirements.
- Do not connect the device to more than one power source. Otherwise, the device could be damaged.
- When working at heights, follow all safety procedures and use the required protective equipment.
- Do not expose the device to direct sunlight or heat sources.
- Do not install the device in damp, dusty, or smoky locations.
- Install the device in a well-ventilated location and do not block its ventilation.
- Use the power adapter or power supply provided by the device manufacturer.
- The power supply must meet the ES1 requirements of IEC 62368-1 and must not exceed PS2. The power supply requirements are governed by the device's rating label.
- Connect Class I electrical appliances to a socket with protective earthing.
Functional Elements
- LED indicator (green) – signals pairing and alarm (see Signaling).
- Ext. input connector – for connecting the included connecting cable and an external wired NC/NO detector.
- Power switch – turns the device on and off.
- Tamper contact – triggers an alarm when the rear cover is opened or the detector is removed from the mounting plate.
- Magnet – the second part of the detector; installed on the fixed part of the door or window frame.
Operating Principle
Door Guard detects the opening or closing of doors and windows using a pair of modules – a detector with an integrated reed relay (reed switch) and a permanent magnet. The operating principle is based on a magnetic field: as long as the detector and magnet are close together, the reed contact circuit is closed. As soon as the magnet moves away from the detector beyond the limit distance, the reed switch opens and the detector immediately sends a signal to the SAFE security system hub.
When an alarm is triggered, the detector passes the event to the hub and the user receives a notification in the ProSAFE. The current door status (open/closed) is available in the app in real time regardless of whether the system is armed.
Magnetic contact
The detector is designed for installation on non-metallic doors and windows of all types and designs. The alarm is triggered when the magnet moves away from the detector beyond the detection limit, which differs depending on the axis of relative movement of the two parts (see Detection Characteristics below).
Detection characteristics
The detection gap is measured in three axes of relative movement between the detector and the magnet. Signal I (intrusion) indicates intrusion – alarm, signal S (stand by) indicates the idle state.
| Axis of movement | Event | Detector–magnet gap | Signal |
|---|---|---|---|
| Y | Far | 33 mm | I |
| Close | 28 mm | S | |
| X+ | Far | 20 mm | I |
| Close | 18 mm | S | |
| X− | Far | 20 mm | I |
| Close | 18 mm | S | |
| Z+ | Far | 38 mm | I |
| Close | 26 mm | S | |
| Z− | Far | 28 mm | I |
| Close | 26 mm | S |
External (wired) input
The detector is equipped on the rear side with one NC/NO potential-free input (configurable in the app), which is used to connect an external wired device using the supplied connecting cable. This input allows easy integration of additional security elements into the SAFE system, including third-party devices – for example a flammable or explosive gas detector, an armored contact for garage doors, a flood detector, or a wired magnetic contact operating on the normally closed circuit principle.
SAFE Keeper protocol
Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:
- AES-128 encryption,
- frequency hopping as protection against interference,
- range up to 1 200 m in open space,
- cloud-based device firmware update.
In the event of radio signal interference, SAFE Keeper notifies the user, and the device automatically retunes to an interference-free frequency band.
Adding to the System
Before adding the device
- Install the app ProSAFE and log in to your account.
- Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection and firmware v1.001.0000000.7.R.220106 or newer.
- The hub must be in the Disarmed state.
How to add Door Guard
- In the ProSAFE app, open your hub and click Device.
- Click + Add device.
- Scan the QR code with the serial number on the detector and click Next.
- Once the detector is found, click Next.
- Following the on-screen instructions, turn on the detector by switching the power switch to position ON and click Next.
- Wait for pairing to complete.
- Enter the detector name, select the area (zone), and click Done.
States
You can view the current detector status in the ProSAFE app by selecting the detector in the Devices list.
| Parameter | Meaning |
|---|---|
| Temporarily disable | Detector functional status
|
| Connection status | Connection between the detector and the hub
|
| Signal strength | Radio signal level: none / low / weak / good / excellent |
| Battery status | Full / sufficient / medium / insufficient / low |
| Tamper status | Indicates that the detector has been removed from the mounting plate or that the rear cover has been opened |
| Temperature | Current ambient temperature measured by the integrated sensor |
| Door detector status | Open / closed – the current position of the magnet relative to the detector |
| 24-hour zone | Enabled / disabled – detection independent of the system's arming status |
| Entry / exit delay | The configured delay times for entry and exit |
| Connection via repeater | Whether the detector forwards messages to the hub via a signal repeater |
| Firmware version | Current detector firmware version |
Settings
You can change the settings in the ProSAFE app: select the detector in the Devices list and click the edit icon.
| Settings | Value |
|---|---|
| Device configuration | Displaying and editing the detector's name, type, serial number, and model |
| Area (zone) | Assigning the detector to a system area |
| Temporarily disable | Allow (default) / Disable tamper alarm only / Disable |
| LED indicator | On (default) / off – when off, the LED does not light up regardless of the device's status |
| 24-hour zone | Enabled – the detector monitors even when the system is disarmed |
| Home Armed mode | Including the detector among the selected devices activated in Home Armed mode |
| Home Armed mode delay | Arming with a delayed alarm; functional only if Home Armed mode is enabled first |
| Delay time | Entry delay max. 45 s (according to EN 50131-1), exit 0–120 s |
| Access to the external device | Wiring of the wired device connected to the detector's external input |
| Siren linkage | Linking the detector's alarm to the siren |
| Video alarm linkage | Linking the detector's alarm to the selected video channel of the hub |
| Signal strength test | Verification of the radio connection quality at the installation site |
| Detection test | Verifying the detector's function (opening/closing the magnetic contact) |
| Transmission power | High / low / automatic – higher power extends the range and increases consumption
|
| Firmware update | Remote firmware update |
| Remove device | Deleting the detector from the system (swipe left in the Devices list) |
Signaling
| LED indication | Event |
|---|---|
| Fast green blinking | Pairing mode, or reduced-sensitivity mode (low transmission power) |
| Lights up green for 2 s | Successful pairing with the hub |
| Slow green blinking for 3 s | Pairing failed |
| Continuously lit green | An alarm has been triggered |
| Off | The LED indicator is turned off in the settings, or the device is switched off |
Choosing the installation location
The detector is designed for installation on non-metallic doors and windows of all types and designs. The detector is mounted on the moving part (the door/window sash), and the magnet on the fixed part of the frame, so that when closed, the two parts are exactly aligned with each other.
Signal strength
Before final installation, test the signal strength in the app (Signal strength test). The recommended minimum value is 2 bars. If the signal is weak, move the detector or use a signal repeater.
Relative position of the detector and magnet
The detection gap between the detector and the magnet is less than 40 mm and differs depending on the axis of relative movement (see Detection characteristics). Align both parts exactly against each other according to the marks on the cover, and always perform a detection test after installation – open and close the door or window and verify that the app correctly registered the change of state.
Detector installation
The detector can be mounted in two ways: quickly using double-sided adhesive tape (included in the package), or using screws and mounting material – the second method is required if the installation must meet security grade 2. Before final installation, we recommend temporarily attaching both parts at the installation site and performing a signal strength test and a detection test.
Mounting using adhesive tape
- Clean and degrease the surface of the door/window and the frame at the installation site.
- Stick the double-sided adhesive tape onto the rear side of the detector and the magnet.
- Press the detector onto the moving part (the sash) and the magnet onto the fixed part of the frame so that they are exactly aligned when closed.
Mounting using screws (security grade 2)
- Following the holes in the mounting plate, drill 4 holes into the frame and into the door/window sash, and insert the wall plugs (included in the mounting kit).
- Align the holes in the plate with the wall plugs.
- Attach the mounting plates using ST3×18 self-tapping screws mm.
- Place the detector body, or the magnet, onto the mounting plate by sliding it in the direction of the arrow.
Functionality Test
After installation, verify the correct function of the detector:
- Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
- Detection test – open and close the door or window and verify that the app immediately registered the change of state (open/closed).
- Tamper test – remove the detector from the mounting plate, or open the rear cover, and verify that a tamper notification was received in the app.
- If an external device is connected, verify that triggering it generates the corresponding event in the app.
Battery replacement
The detector is powered by 1× CR123A lithium battery (3 H) with a lifespan of up to 4 years when activated twice a day (ext. input NO; 2 years with ext. input NC or pulse mode). The ProSAFE app will notify you of a low battery.
- Remove the detector from the mounting plate by sliding it against the direction of the arrow and turn it off using the power switch.
- Open the rear cover – press the latch that holds the cover.
- Remove the old battery and insert a new CR123A battery. Observe the correct polarity – the side marked "+" must face the rear cover.
- Close the rear cover.
- Turn on the device using the switch, setting it to position ON.
- Return the detector to the mounting plate by sliding it in the direction of the arrow.
Maintenance
- Keep the cover of the detector and magnet clean – wipe off dust with a dry, soft cloth. Do not use aggressive cleaning agents.
- Regularly check that the detector and magnet remain exactly aligned when the door/window is closed.
- Regularly check the battery status and signal strength in the ProSAFE app.
- Perform a detection test again after every manipulation of the door, window, or detector.
- Do not disassemble the detector, and protect it from moisture, dust, and direct sunlight.
Technical Specifications
| Detection parameters | |
| Detection type | Magnetic |
| Sensor | Reed contact (reed switch), up to 2 million cycles |
| Use scenario | Non-metallic doors and windows |
| Detection range (gap) | < 40 mm (1.57") |
| Test mode | Yes |
| Temperature sensor | |
| Measuring range | −15 °C to +65 °C (indoor environments) |
| Accuracy / resolution | ±1 °C / 1 °C |
| Wireless transmission – SAFE Keeper | |
| Carrier frequency | 868,0–868,6 MHz |
| Transmitter power (EIRP) | Limit 25 mW |
| Communication distance | Up to 1 200 m (3 937,01 ft) in open space |
| Communication type | Two-way |
| Encryption | AES128 |
| Frequency hopping | Yes |
| Interface and functions | |
| Indication | 1× green LED |
| Control Devices | 1× power switch |
| Tamper contact | Yes (tamper) |
| Remote update | Yes (cloud) |
| Search | Signal strength detection |
| Low battery notification | Yes |
| Inputs/outputs | 1× NC/NO potential-free alarm input (configurable) |
| General | |
| Power supply | 1× CR123A battery, 3 V (included in the package) |
| Power consumption | Max. 125 mW |
| Current draw | ≤ 12 µA (operation) / ≤ 2,3 mA (alarm) |
| Battery life | When activated 2× daily with battery efficiency of 70 %: 4 years (ext. input NO) / 2 years (ext. input NC or pulse) |
| Operating temperature | −10 °C to +55 °C (indoor environments) |
| Operating humidity | 10–90 % RH |
| Housing material | PC + ABS |
| Color | White (SAFE 38100) / black (SAFE 38101) |
| Product dimensions | 100.2 × 20.8 × 20.3 mm |
| Package dimensions | 137.0 × 98.0 × 28.0 mm |
| Weight (net) | 70 g |
| Weight (gross) | 128,7 g |
| Installation | On mounting plate (adhesive tape or screws) |
| Compatibility | Hub 2 Plus LTE (SAFE 38300), firmware v1.001.0000000.7.R.220106 or newer |
| Certification | CE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-6:2017; EN 50131-5-3:2017; EN 50131-2-6:2008; Security grade 2; Environmental class II |
Package Contents
- Door Guard (detector + magnet) – 1 set
- Double-sided adhesive tape – 2 pcs
- Connecting cable (ext. input) – 1 pcs
- Quick user guide – 1 pcs
- Legal and regulatory information – 1 pcs
- Mounting kit (screws, wall plugs) – 1 set
- QR code with the user manual – 1 pcs
Safety Notices
- Do not install the device in locations exposed to direct sunlight or near heat sources. Keep it away from moisture, dust, and soot.
- Replace unnecessary or depleted batteries only with batteries of the same type and model (CR123A).
- Keep batteries out of the reach of children to prevent swallowing.
- Do not throw batteries into fire or a hot oven, crush them, or cut them open – risk of explosion.
- Do not leave batteries in environments with extremely high temperatures or expose them to extremely low air pressure – risk of explosion or leakage of flammable liquid and gas.
- If a battery is suspected to have been swallowed or to have entered the body, seek medical help immediately.
- Do not dispose of the product with regular household waste – hand it in for recycling through the electrical equipment take-back system.
Warranty
The SAFE Door Guard device is covered by a warranty 36 months from the date of sale. The warranty does not cover the battery or defects caused by failure to follow the instructions in this manual.
If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.
Gallery
Need Help?
SAFE HOME europe technical support:
Email: info@safe-home.eu · Phone: (+420) 581 222 262
Website: www.smart-safe.eu