Door Guard is a wireless universal magnetic door/window contact for the SAFE security system, providing reliable protection for windows and doors of all types and designs. The device consists of two modules – the detector and the magnet – and is equipped with one NC/NO input for connecting an external wired device. The detector contains a highly reliable reed relay capable of up to 2 million opening cycles, and communicates with the SAFE system using an encrypted protocol SAFE Keeper at a distance of up to 1 200 m in open space.

1 200 mradio signal range
4 yearsbattery life (ext. NO input)
<40 mmmagnet detection gap
2 mil.reed relay cycles
Grade 2security grade according to EN 50131
4 cmDetection distance < 4 cm
Radio signal range up to 1200 m
Cloud-based device firmware update
Input for connecting an external wired NC detector
Smart bracket for quick and easy installation
Security grade 2 according to ČSN EN 50131
Up to 5 years of battery operation
Tamper protection against sabotage and unauthorized manipulation of the device
Adding the device to the system by scanning a QR code
Integrated temperature sensor
Two-way information transfer between devices
Data encryption using the AES algorithm with rolling code
Interference detection
Simple device installation

Preface

General

This user manual describes the installation, functions, and operation of the wireless magnetic door/window contact (hereinafter the "detector"). Before using the device, read this manual carefully and keep it for future reference.

Safety Instructions

The following signal words may appear in the user manual:

Signal WordMeaning
DANGERIndicates a high potential hazard that, if not avoided, may result in death or serious injury.
WARNINGIndicates a medium or low potential hazard that could cause minor or moderate injury if not avoided.
CAUTIONIndicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome.
TIPProvides methods to help you solve a problem or save time.
NOTEProvides additional information, such as emphasis and supplementary text.

Revision History

VersionRevision ContentRelease Date
V1.0.0First release.August 2026

Privacy Notice

As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the Manual

Important Safeguards and Warnings

This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.

Operating Requirements

CAUTION

Installation Requirements

WARNING
CAUTION

Functional Elements

Functional elements of the Door Guard detector – detector with open cover and magnet, numbered diagram
Functional elements of the Door Guard detector (magnet on the left, detector with open cover in the middle, rear view of the magnet on the right)
  1. LED indicator (green) – signals pairing and alarm (see Signaling).
  2. Ext. input connector – for connecting the included connecting cable and an external wired NC/NO detector.
  3. Power switch – turns the device on and off.
  4. Tamper contact – triggers an alarm when the rear cover is opened or the detector is removed from the mounting plate.
  5. Magnet – the second part of the detector; installed on the fixed part of the door or window frame.
The detector is installed on the moving part of the door or window, and the magnet on the fixed frame. Both parts can be attached using double-sided adhesive tape or screws with mounting materials (included).

Operating Principle

Door Guard detects the opening or closing of doors and windows using a pair of modules – a detector with an integrated reed relay (reed switch) and a permanent magnet. The operating principle is based on a magnetic field: as long as the detector and magnet are close together, the reed contact circuit is closed. As soon as the magnet moves away from the detector beyond the limit distance, the reed switch opens and the detector immediately sends a signal to the SAFE security system hub.

When an alarm is triggered, the detector passes the event to the hub and the user receives a notification in the ProSAFE. The current door status (open/closed) is available in the app in real time regardless of whether the system is armed.

Magnetic contact

The detector is designed for installation on non-metallic doors and windows of all types and designs. The alarm is triggered when the magnet moves away from the detector beyond the detection limit, which differs depending on the axis of relative movement of the two parts (see Detection Characteristics below).

Detection characteristics

The detection gap is measured in three axes of relative movement between the detector and the magnet. Signal I (intrusion) indicates intrusion – alarm, signal S (stand by) indicates the idle state.

Axes of relative movement between the detector and the magnet (X, Y, Z) for measuring the detection characteristics
Axes of relative movement of the detector (left) and the magnet (right)
Axis of movementEventDetector–magnet gapSignal
YFar33 mmI
Close28 mmS
X+Far20 mmI
Close18 mmS
X−Far20 mmI
Close18 mmS
Z+Far38 mmI
Close26 mmS
Z−Far28 mmI
Close26 mmS
The actual reliable detection distance is less than 40 mm in all axes. Therefore, always maintain the recommended distance between the two parts during installation (see Choosing the installation location) and verify the function with a detection test.

External (wired) input

The detector is equipped on the rear side with one NC/NO potential-free input (configurable in the app), which is used to connect an external wired device using the supplied connecting cable. This input allows easy integration of additional security elements into the SAFE system, including third-party devices – for example a flammable or explosive gas detector, an armored contact for garage doors, a flood detector, or a wired magnetic contact operating on the normally closed circuit principle.

The external input (1-channel digital input) does not have its own certification according to EN 50131. To maintain security grade 2 of the entire system, connect only devices with corresponding certification.

SAFE Keeper protocol

Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:

In the event of radio signal interference, SAFE Keeper notifies the user, and the device automatically retunes to an interference-free frequency band.

Adding to the System

Adding a device by scanning a QR code
Adding a device by scanning a QR code

Before adding the device

  1. Install the app ProSAFE and log in to your account.
  2. Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection and firmware v1.001.0000000.7.R.220106 or newer.
  3. The hub must be in the Disarmed state.

How to add Door Guard

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the detector and click Next.
  4. Once the detector is found, click Next.
  5. Following the on-screen instructions, turn on the detector by switching the power switch to position ON and click Next.
  6. Wait for pairing to complete.
  7. Enter the detector name, select the area (zone), and click Done.
Before final installation, check the signal strength of the connection to the hub at the installation site in the app – the recommended value is at least 2 bars.
If pairing fails (the LED blinks slowly for 3 s), check that the hub is online and in the Disarmed state, and repeat the procedure.

States

Device Details — Door Guard detector status overview
Device Details — Door Guard detector status overview

You can view the current detector status in the ProSAFE app by selecting the detector in the Devices list.

ParameterMeaning
Temporarily disableDetector functional status
  • Enable – the detector is fully functional
  • Disable tamper alarm only
  • Disable – the detector is taken out of operation
Connection statusConnection between the detector and the hub
  • Online – the detector is communicating
  • Offline – loss of connection
Signal strengthRadio signal level: none / low / weak / good / excellent
Battery statusFull / sufficient / medium / insufficient / low
Tamper statusIndicates that the detector has been removed from the mounting plate or that the rear cover has been opened
TemperatureCurrent ambient temperature measured by the integrated sensor
Door detector statusOpen / closed – the current position of the magnet relative to the detector
24-hour zoneEnabled / disabled – detection independent of the system's arming status
Entry / exit delayThe configured delay times for entry and exit
Connection via repeaterWhether the detector forwards messages to the hub via a signal repeater
Firmware versionCurrent detector firmware version

Settings

Door Guard detector settings in the ProSAFE app
Door Guard detector settings in the ProSAFE app

You can change the settings in the ProSAFE app: select the detector in the Devices list and click the edit icon.

SettingsValue
Device configurationDisplaying and editing the detector's name, type, serial number, and model
Area (zone)Assigning the detector to a system area
Temporarily disableAllow (default) / Disable tamper alarm only / Disable
LED indicatorOn (default) / off – when off, the LED does not light up regardless of the device's status
24-hour zoneEnabled – the detector monitors even when the system is disarmed
Home Armed modeIncluding the detector among the selected devices activated in Home Armed mode
Home Armed mode delayArming with a delayed alarm; functional only if Home Armed mode is enabled first
Delay timeEntry delay max. 45 s (according to EN 50131-1), exit 0–120 s
Access to the external deviceWiring of the wired device connected to the detector's external input
Siren linkageLinking the detector's alarm to the siren
Video alarm linkageLinking the detector's alarm to the selected video channel of the hub
Signal strength testVerification of the radio connection quality at the installation site
Detection testVerifying the detector's function (opening/closing the magnetic contact)
Transmission powerHigh / low / automatic – higher power extends the range and increases consumption
  • When set to Low, the detector switches to reduced-sensitivity mode
Firmware updateRemote firmware update
Remove deviceDeleting the detector from the system (swipe left in the Devices list)

Signaling

LED indicationEvent
Fast green blinkingPairing mode, or reduced-sensitivity mode (low transmission power)
Lights up green for 2 sSuccessful pairing with the hub
Slow green blinking for 3 sPairing failed
Continuously lit greenAn alarm has been triggered
OffThe LED indicator is turned off in the settings, or the device is switched off

Choosing the installation location

The detector is designed for installation on non-metallic doors and windows of all types and designs. The detector is mounted on the moving part (the door/window sash), and the magnet on the fixed part of the frame, so that when closed, the two parts are exactly aligned with each other.

Metal frames and metal door reinforcement can affect the magnetic field and the reliability of detection. Always verify the function with a detection test before final installation.

Signal strength

Before final installation, test the signal strength in the app (Signal strength test). The recommended minimum value is 2 bars. If the signal is weak, move the detector or use a signal repeater.

Relative position of the detector and magnet

The detection gap between the detector and the magnet is less than 40 mm and differs depending on the axis of relative movement (see Detection characteristics). Align both parts exactly against each other according to the marks on the cover, and always perform a detection test after installation – open and close the door or window and verify that the app correctly registered the change of state.

Detector installation

The detector can be mounted in two ways: quickly using double-sided adhesive tape (included in the package), or using screws and mounting material – the second method is required if the installation must meet security grade 2. Before final installation, we recommend temporarily attaching both parts at the installation site and performing a signal strength test and a detection test.

Mounting using adhesive tape

  1. Clean and degrease the surface of the door/window and the frame at the installation site.
  2. Stick the double-sided adhesive tape onto the rear side of the detector and the magnet.
  3. Press the detector onto the moving part (the sash) and the magnet onto the fixed part of the frame so that they are exactly aligned when closed.

Mounting using screws (security grade 2)

  1. Following the holes in the mounting plate, drill 4 holes into the frame and into the door/window sash, and insert the wall plugs (included in the mounting kit).
  2. Align the holes in the plate with the wall plugs.
  3. Attach the mounting plates using ST3×18 self-tapping screws mm.
  4. Place the detector body, or the magnet, onto the mounting plate by sliding it in the direction of the arrow.
Installing the Door Guard detector – assembling the mounting plates with screws (A) and placing the detector and magnet onto the plates by sliding in the direction of the arrow (B)
Mounting using screws: assembling the mounting plates (A) and placing both parts onto the plates (B)
If an external wired device is connected to the detector, route the connecting cable through the external input connector before closing and attaching the detector to the mounting plate.

Functionality Test

After installation, verify the correct function of the detector:

  1. Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
  2. Detection test – open and close the door or window and verify that the app immediately registered the change of state (open/closed).
  3. Tamper test – remove the detector from the mounting plate, or open the rear cover, and verify that a tamper notification was received in the app.
  4. If an external device is connected, verify that triggering it generates the corresponding event in the app.
The detection test activates within the detector's communication interval with the hub – wait a moment after starting the test.

Battery replacement

The detector is powered by 1× CR123A lithium battery (3 H) with a lifespan of up to 4 years when activated twice a day (ext. input NO; 2 years with ext. input NC or pulse mode). The ProSAFE app will notify you of a low battery.

Replacing the battery: removing the detector from the mounting plate, opening the rear cover, and inserting the CR123A battery
Replacing the battery: removing the detector from the plate (A), opening the rear cover and inserting the battery (B), returning the detector to the mounting plate (C)
  1. Remove the detector from the mounting plate by sliding it against the direction of the arrow and turn it off using the power switch.
  2. Open the rear cover – press the latch that holds the cover.
  3. Remove the old battery and insert a new CR123A battery. Observe the correct polarity – the side marked "+" must face the rear cover.
  4. Close the rear cover.
  5. Turn on the device using the switch, setting it to position ON.
  6. Return the detector to the mounting plate by sliding it in the direction of the arrow.
Replace only with a battery of the same type and model (CR123A). Do not throw used batteries into fire or a hot oven, crush them, or cut them open – risk of explosion. Keep batteries out of the reach of children.

Maintenance

Technical Specifications

Detection parameters
Detection typeMagnetic
SensorReed contact (reed switch), up to 2 million cycles
Use scenarioNon-metallic doors and windows
Detection range (gap)< 40 mm (1.57")
Test modeYes
Temperature sensor
Measuring range−15 °C to +65 °C (indoor environments)
Accuracy / resolution±1 °C / 1 °C
Wireless transmission – SAFE Keeper
Carrier frequency868,0–868,6 MHz
Transmitter power (EIRP)Limit 25 mW
Communication distanceUp to 1 200 m (3 937,01 ft) in open space
Communication typeTwo-way
EncryptionAES128
Frequency hoppingYes
Interface and functions
Indication1× green LED
Control Devices1× power switch
Tamper contactYes (tamper)
Remote updateYes (cloud)
SearchSignal strength detection
Low battery notificationYes
Inputs/outputs1× NC/NO potential-free alarm input (configurable)
General
Power supply1× CR123A battery, 3 V (included in the package)
Power consumptionMax. 125 mW
Current draw≤ 12 µA (operation) / ≤ 2,3 mA (alarm)
Battery lifeWhen activated 2× daily with battery efficiency of 70 %: 4 years (ext. input NO) / 2 years (ext. input NC or pulse)
Operating temperature−10 °C to +55 °C (indoor environments)
Operating humidity10–90 % RH
Housing materialPC + ABS
ColorWhite (SAFE 38100) / black (SAFE 38101)
Product dimensions100.2 × 20.8 × 20.3 mm
Package dimensions137.0 × 98.0 × 28.0 mm
Weight (net)70 g
Weight (gross)128,7 g
InstallationOn mounting plate (adhesive tape or screws)
CompatibilityHub 2 Plus LTE (SAFE 38300), firmware v1.001.0000000.7.R.220106 or newer
CertificationCE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-6:2017; EN 50131-5-3:2017; EN 50131-2-6:2008; Security grade 2; Environmental class II
Detector dimensional drawing: 21.0 × 100.2 × 21.3 mm
Detector dimensions (mm)
The Door Guard model range is available in two color variants: SAFE 38100 (white, EAN 0728204234730) and SAFE 38101 (black, EAN 0728204235119). The parameters of both variants are identical.

Package Contents

Door Guard package contents
  1. Door Guard (detector + magnet) – 1 set
  2. Double-sided adhesive tape – 2 pcs
  3. Connecting cable (ext. input) – 1 pcs
  4. Quick user guide – 1 pcs
  5. Legal and regulatory information – 1 pcs
  6. Mounting kit (screws, wall plugs) – 1 set
  7. QR code with the user manual – 1 pcs

Safety Notices

Warranty

The SAFE Door Guard device is covered by a warranty 36 months from the date of sale. The warranty does not cover the battery or defects caused by failure to follow the instructions in this manual.