Product Manuals / Door/window contacts

Wireless door/window contact with tilt and vibration detection compatible with the ProSAFE app
SAFE Door Guard Plus (SAFE 38110)

User Manual

Updated 20. 8. 2026

Product Page Datalist (PDF)
SAFE Door Guard Plus detector

Door Guard Plus is a wireless, universal SAFE magnetic contact for detecting opening, shock, and tilt, providing reliable protection for windows and doors of all types and designs, supplemented with an accelerometer for a wider range of applications. The device consists of two modules – the detector and the magnet. In addition to monitoring the open/closed status of doors and windows, it can also be used to monitor the movement or position changes of other objects, such as paintings, safes, or other valuable items. It communicates with the SAFE system using an encrypted protocol SAFE Keeper at a frequency of 868 MHz up to a distance of 1 200 m in open space.

1 200 mradio signal range
<40 mmgap for triggering the alarm
25°adjustable tilt detection
4 yearsbattery life (ext. NO input)
Grade 2security grade according to EN 50131
4 cmDetection distance < 4 cm
Radio signal range up to 1200 m
Cloud-based device firmware update
Input for connecting an external wired NC detector
Tilt and position change detection
Smart bracket for quick and easy installation
Security grade 2 according to ČSN EN 50131
Up to 5 years of battery operation
Tamper protection against sabotage and unauthorized manipulation of the device
Adding the device to the system by scanning a QR code
Integrated temperature sensor
Two-way information transfer between devices
Data encryption using the AES algorithm with rolling code
Interference detection
Simple device installation

Preface

General

This user manual describes the installation, functions, and operation of the wireless door/window contact with tilt and vibration detection (hereinafter referred to as the "detector"). Before using the device, please read this manual carefully and keep it for future reference.

Safety Instructions

The following signal words may appear in the user manual:

Signal WordMeaning
DANGERIndicates a high potential hazard that, if not avoided, may result in death or serious injury.
WARNINGIndicates a medium or low potential hazard that could cause minor or moderate injury if not avoided.
CAUTIONIndicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome.
TIPProvides methods to help you solve a problem or save time.
NOTEProvides additional information, such as emphasis and supplementary text.

Revision History

VersionRevision ContentRelease Date
V1.0.0First release.August 2026

Privacy Notice

As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the Manual

Important Safeguards and Warnings

This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.

Operating Requirements

CAUTION

Installation Requirements

WARNING
CAUTION

Functional Elements

Functional elements of the Door Guard Plus detector and magnet – numbered diagram
Functional elements of the Door Guard Plus detector and magnet
  1. LED indicator (green) – indicates pairing, alarm, and test results (see Signaling).
  2. Ext. input connector – for connecting the connecting cable of a wired external detector.
  3. Power switch (ON/OFF) – turns the device on and off.
  4. Tamper contact – triggers an alarm when the rear cover is opened or the detector is removed from the mounting plate.
  5. Magnet – a separate module attached to the moving part of the door/window or to the frame; moving it closer to or away from the detector controls the reed relay.

The detector is installed on the fixed part of the window or door frame, and the magnet on the moving part (the sash). The arrangement can also be reversed – what matters is the relative position of the two modules in the closed state.

Operating Principle

Door Guard Plus is a sophisticated security device consisting of two key components: a detector with an integrated, highly reliable reed relay capable of up to 2 million opening cycles, and a strong permanent magnet. In addition to the reed switch, the detector also contains a three-axis accelerometer for detecting shocks and changes in tilt angle.

Magnetic contact

The operating principle is based on the magnetic field – as soon as the magnet moves away from the detector, the reed switch activates and an opening alarm is triggered. The actual distance at which the alarm is triggered depends on the relative orientation of the two modules (the axis of separation/approach) and has been verified by testing according to EN 50131-2-6:

Axis / sampleEventAir gap distance (declared = verified)
1 (Y)Separation / approach34 mm / 28 mm
2 (X+)Separation / approach20 mm / 18 mm
3 (X-)Separation / approach20 mm / 18 mm
4 (Z+)Separation / approach46 mm / 40 mm
5 (Z-)Separation / approach46 mm / 39 mm
The detector is primarily designed for non-metallic doors and windows. The declared gap for triggering the alarm is <40 mm; for reliable function even with greater play in the sash, we recommend keeping the installation gap as small as possible.

Vibration and shock detection

The built-in three-axis accelerometer can detect vibrations or impacts that may indicate an attempted forced entry or tampering with the magnetic contact. The alarm is triggered if the intensity of the shock exceeds the set sensitivity level (high / medium – default / low). This function can be supplemented with the option Ignore first vibration – if the interval between two shocks is shorter than 1 second, the alarm is triggered; otherwise, the alarm does not occur. We recommend enabling this option in installation environments prone to shocks (e.g., at entrance gates).

Tilt and position change detection

The accelerometer also detects changes in the vertical tilt angle. The alarm is triggered if the tilt of the detector exceeds the configured tilt angle (5 / 10 / 15 / 20 / 25°, default 5°) and the tilted state lasts longer than the configured tilt alarm delay (1–60 s, default 2 s). This allows the detector to also be used for monitoring the tilting or removal of paintings, safes, or other valuable items.

External wired input

Door Guard Plus is equipped on the rear side with one potential-free input (1× NC/NO, configurable, or pulse), which is used to connect an external wired detector using the supplied connecting cable. This input allows easy integration of additional security elements, including third-party devices – for example a flammable or explosive gas detector, an armored contact for gates, a flood detector, or another wired magnetic contact operating on the normally closed/open circuit principle. This function significantly increases the flexibility and expands the modular capabilities of the entire SAFE security system.

The external input function is not certified under IMQ-SISTEMI DI SICUREZZA.

SAFE Keeper protocol

Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:

Adding to the System

Adding a device by scanning a QR code
Adding a device by scanning a QR code

Before adding the device

  1. Install the app ProSAFE and log in to your account.
  2. Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
  3. The hub must be in the Disarmed state.
Requires app version 1.99.400 or newer and hub firmware v1.001.0000005.0.R.221230 or newer.

How to add Door Guard Plus

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the detector and click Next.
  4. Once the device is found, click Next.
  5. Following the on-screen instructions, turn on the detector by switching the power switch to position ON and click Next.
  6. Wait for pairing to complete – successful pairing is confirmed by the LED lighting up for 2 seconds.
  7. Enter the detector name, select the area (zone), and click Done.
If pairing fails (the LED blinks slowly for 3 s), check that the hub is online and in the Disarmed state, and repeat the procedure.

States

Device Details — detector status overview
Device Details — detector status overview

You can view the current detector status in the ProSAFE app by selecting the detector in the Devices list.

ParameterMeaning
Temporarily disableDetector functional status
  • Enable – the detector is fully functional
  • Disable tamper alarm only – the system ignores only tamper messages
  • Disable – the detector is taken out of operation
TemperatureCurrent ambient temperature measured by the integrated sensor
Signal strengthRadio signal level: none / low / weak / good / excellent
Battery statusFull / sufficient / medium / insufficient / low
Tamper statusIndicates that the detector has been removed from the mounting plate or that the rear cover has been opened
Connection statusOnline – the detector is communicating / Offline – loss of connection
Entry / exit delayThe configured delay times for entering and exiting the zone
Door detector statusOpen / closed
External inputStatus of the connected external wired detector (after the external device configuration has been enabled)
24-hour zoneEnabled / disabled – detection independent of the system's arming status
Transmission via repeaterWhether the detector communicates with the hub via a signal repeater
Firmware versionCurrent detector firmware version

Settings

Detector settings in the ProSAFE app
Detector settings in the ProSAFE app

You can change the settings in the ProSAFE app: select the detector in the Devices list and click the edit icon.

SettingsValue
Device configurationDisplaying the name, type, serial number, and model; editing the device name
Area (zone)Assigning the detector to a system area
Zone numberThe zone number assigned to the detector's alarm – cannot be configured
Temporarily disableEnable (default) – the detector is fully functional
  • Disable tamper alarm only – the system ignores only tamper messages
  • Disable – the detector is taken out of operation
LED indicatorOn (default) / off – when off, the LED does not light up regardless of the device's status
24-hour zoneA device in a 24-hour protection zone is always active, regardless of the system's arming status
Home Armed modeWhen the system is partially armed, the detector is activated only if Home Armed mode is enabled for it
Home Armed mode delayEnabling the delay activates the selected device in Home Armed mode only after the configured time has elapsed
  • Functional only when Home Armed mode is enabled
Entry / exit delayEntry delay max. 45 s (according to EN 50131-1), exit 0–120 s; the system's arming becomes effective only after the delay has elapsed
Door detector configurationEnabling / disabling the alarm when the door is opened by the detector
External device configurationEnabling / disabling the external input; once enabled, its status is displayed
  • Siren signaling of the external input
  • Type of external input: normally open (default) / normally closed / pulse
Vibration detector configurationEnabling / disabling shock detection
  • Siren signaling of the shock alarm
  • Sensitivity: high / medium (default) / low
  • Ignore first vibration (off by default) – recommended in environments prone to shocks
Tilt detector configurationEnabling / disabling tilt detection
  • Siren signaling of the tilt alarm
  • Tilt angle: 5 / 10 / 15 / 20 / 25° (default 5°)
  • Tilt alarm delay: 1–60 s (default 2 s)
ChimeWhen enabled, opening the door while the system is disarmed triggers an audible chime signal from the indoor siren
Temperature detectionAlarm when the set temperature range (min/max) is exceeded
Transmission powerHigh / low / automatic – higher power extends the range and increases consumption
  • The Low option switches the detector to reduced-sensitivity mode
Signal strength testVerification of the radio connection quality at the installation site
Detection testVerification of device functionality
Cloud updateRemote firmware update
Remove deviceDeleting the detector from the system (swipe left in the Devices list)
The External Device Configuration, Vibration Detector, and Tilt Detector configuration items are not certified under IMQ-SISTEMI DI SICUREZZA.

Signaling

LED indicationEvent
Fast green blinkingPairing mode, or reduced-sensitivity mode (low transmission power)
Lights up green for 2 sSuccessful pairing with the hub
Slow green blinking for 3 sPairing failed
Continuously lit greenAn alarm was triggered (opening, shock, tilt, or tamper)
OffThe LED indicator is turned off in the settings, or the device is switched off

Choosing the installation location

Mount the detector on the fixed part of the door or window frame, and the magnet on the moving part (the sash), so that in the closed state both modules are as close together as possible and on the same axis. Orient the opening for connecting the external input's connecting cable according to the cabling requirements.

Signal strength

Before final installation, test the signal strength in the app (Signal strength test). The recommended minimum value is 2 bars. If the signal is weak, move the detector or use a signal repeater.

Where not to install the detector and magnet

  1. On metal doors and window frames, or in their immediate vicinity – metal weakens the magnetic field and reduces the reliability of detection as well as the range of the radio signal. The detector is primarily designed for non-metallic doors and windows.
  2. In locations outside the declared range of operating temperature and humidity (the device is intended for indoor installation).
  3. In locations exposed to excessive vibrations unrelated to an intrusion attempt (e.g., near machinery) – this increases the risk of false shock detection alarms; in such cases, reduce the sensitivity or enable the Ignore First Vibration function.
  4. In locations with a weak hub radio signal.

Detector installation

Both modules – the detector and the magnet – can be attached in two ways: quickly using double-sided adhesive tape, or with screws using the included mounting kit, if the installation requires security grade 2 according to ČSN EN 50131.

Mounting using the mounting kit (screws, security grade 2)

  1. Assemble the parts of the mounting kit as shown in the figure and attach them with screws to the fixed part of the frame (detector) and to the moving part of the door/window (magnet).
  2. Place the detector body, or the magnet, onto the mounting plate by sliding it in the direction of the arrow.
Mounting the Door Guard Plus detector and magnet – assembling the mounting kit and placing it onto the mounting plate
Assembling the mounting kit (A) and placing the detector/magnet onto the mounting plate (B)

Mounting using double-sided adhesive tape

  1. Clean and degrease the installation location on both the frame and the door/window sash.
  2. Attach the mounting plate to the surface using the included double-sided adhesive tape.
  3. Place the device onto the mounting plate by sliding it in the direction of the arrow.
Adhesive tape does not meet the mechanical resistance requirements for security grade 2 – use screw mounting for this purpose.

Functionality Test

After installation, verify the correct function of the detector:

  1. Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
  2. Detection test – open and close the door/window and verify that the app registered the change of state.
  3. Shock detection test – if the function is enabled, gently shake the door/window and verify that, according to the configured sensitivity, the alarm is triggered.
  4. Tilt detection test – if the function is enabled, tilt the protected object by the configured angle for longer than the configured delay, and verify that the alarm is triggered.
  5. Tamper test – remove the detector from the mounting plate or open the rear cover, and verify that a tamper notification was received in the app.
The tests activate within the detector's communication interval with the hub – wait a moment after starting the test.

Battery replacement

The detector is powered by 1× CR123A lithium battery (3 H) with a lifespan of up to 4 years when the external input NO is activated (2 years for the external input NC or pulse), assuming the alarm is triggered twice a day with a battery efficiency of 70 %. The battery is inserted at the factory, so the device can be used immediately. The ProSAFE app will notify you of a low battery.

Replacing the CR123A battery in the Door Guard Plus detector – removing it from the plate, opening the rear cover, and inserting the battery
Removing the detector from the plate (A), opening the cover and inserting the battery (B), closing the cover (C)
  1. Remove the detector from the mounting plate and turn it off using the power switch.
  2. Open the rear cover – press the latch that holds the cover.
  3. Replace the battery. Observe the correct polarity – the side marked "+" must face the rear cover.
  4. Close the rear cover, turn on the device using the switch, setting it to position ON and return it to the mounting plate.
Replace the depleted battery only with a battery of the same type and model (CR123A). Do not throw used batteries into fire or a hot oven, crush them, or cut them open – risk of explosion. Do not expose the battery to extremely high temperatures or extremely low air pressure – risk of explosion or leakage of flammable liquid and gas. Keep batteries out of the reach of children. If battery ingestion is suspected, seek medical attention immediately.

Maintenance

Technical Specifications

Detection parameters
Detection typeMagnetic, position change
SensorThree-axis accelerometer, reed contact
Detection range (gap)<40 mm
Recommended door/window typeNon-metallic
Shock detectionAdjustable, 3 levels
Tilt detectionUp to 25°
Temperature sensor
Measuring range−15 °C to +65 °C (indoor environments)
Accuracy / resolution±1 °C / 1 °C
Inputs / outputs
Alarm input1× NC/NO potential-free (configurable, incl. pulse)
Wireless transmission – SAFE Keeper
Carrier frequency868,0–868,6 MHz
Transmitter power (EIRP)limit 25 mW
Communication distanceUp to 1 200 m in open space
Communication typeTwo-way
EncryptionAES-128
Frequency hoppingYes (automatic)
Interface and functions
Indication1× green LED
Control Devices1× power switch
TamperYes (tamper contact)
Remote updateYes (cloud)
Low battery notificationYes
Test modeYes (signal strength test, detection test)
General
Power supply1× CR123A battery, 3 V
Power consumptionMax. 125 mW
Current draw≤ 12 µA (operation) / ≤ 2,3 mA (alarm)
Battery lifeWhen activated 2× daily, battery efficiency 70 %: 4 years (ext. input NO) / 2 years (ext. input NC or pulse)
Operating temperature−10 °C to +55 °C (indoor environments)
Operating humidity10–90 % RH
Housing materialPC + ABS
ColorWhite (SAFE 38110) / black (SAFE 38111)
Product dimensions100.2 × 20.8 × 20.3 mm
Package dimensions135.0 × 98.5 × 27.8 mm
Weight70 g net / 115 g gross
InstallationOn mounting plate (adhesive tape, or screws for security grade 2)
CompatibilityHub 2 Plus LTE (SAFE 38300), hub firmware v1.001.0000005.0.R.221230 or newer, ProSAFE app v1.99.400 or newer
CertificationCE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-6:2017; EN 50131-5-3:2017; EN 50131-2-6:2008; Security grade 2; Environmental class II

Package Contents

Door Guard Plus package contents
  1. Door Guard Plus (detector + magnet) – 1 set
  2. Double-sided adhesive tape – 2 pcs
  3. Connecting cable (ext. input) – 1 pcs
  4. Quick user guide – 1 pcs
  5. Legal and regulatory information – 1 pcs
  6. Mounting kit (screws) – 1 set
  7. QR code with the user manual – 1 pcs

Safety Notices

Warranty

The SAFE Door Guard Plus device is covered by a warranty 36 months from the date of sale. The warranty does not cover the battery or defects caused by failure to follow the instructions in this manual.

If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.

Gallery

Need Help?

SAFE HOME europe technical support:
Email: info@safe-home.eu  ·  Phone: (+420) 581 222 262
Website: www.smart-safe.eu