Door Guard Plus is a wireless, universal SAFE magnetic contact for detecting opening, shock, and tilt, providing reliable protection for windows and doors of all types and designs, supplemented with an accelerometer for a wider range of applications. The device consists of two modules – the detector and the magnet. In addition to monitoring the open/closed status of doors and windows, it can also be used to monitor the movement or position changes of other objects, such as paintings, safes, or other valuable items. It communicates with the SAFE system using an encrypted protocol SAFE Keeper at a frequency of 868 MHz up to a distance of 1 200 m in open space.
Preface
General
This user manual describes the installation, functions, and operation of the wireless door/window contact with tilt and vibration detection (hereinafter referred to as the "detector"). Before using the device, please read this manual carefully and keep it for future reference.
Safety Instructions
The following signal words may appear in the user manual:
| Signal Word | Meaning |
|---|---|
| DANGER | Indicates a high potential hazard that, if not avoided, may result in death or serious injury. |
| WARNING | Indicates a medium or low potential hazard that could cause minor or moderate injury if not avoided. |
| CAUTION | Indicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome. |
| TIP | Provides methods to help you solve a problem or save time. |
| NOTE | Provides additional information, such as emphasis and supplementary text. |
Revision History
| Version | Revision Content | Release Date |
|---|---|---|
| V1.0.0 | First release. | August 2026 |
Privacy Notice
As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.
About the Manual
- The user manual serves as a reference guide only. There may be minor differences between the information provided and the product.
- We are not liable for any damage resulting from using the product in a manner that does not comply with the instructions in the user manual.
- The manual will be updated according to the latest laws and regulations of the relevant jurisdictions. For detailed information, refer to the printed user manual, scan the QR code, or visit our official website. The manual is for reference purposes only. There may be minor differences between the electronic and paper versions.
- All designs and software are subject to change without prior written notice. Due to product updates, certain differences may occur between the product and the information in the manual. Customer service will provide you with the latest version of the software and supplementary documentation.
- There may be printing errors or discrepancies in the description of functions, operations, and technical data. In the event of doubt or dispute, we reserve the right of final explanation. If the manual (in PDF format) cannot be opened, update your reader software or try a different common reader software.
- All trademarks, registered trademarks, and company names in the manual are the property of their respective owners.
- If you encounter any problems while using the device, visit our website or contact your supplier or customer service.
- In the event of ambiguity or dispute, we reserve the right of final explanation.
Important Safeguards and Warnings
This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.
Operating Requirements
- Before use, make sure the device's power supply is working properly.
- Do not unplug the device's power cable while it is switched on.
- Use the device only within its rated power range.
- Transport, use, and store the device within the permitted humidity and temperature conditions.
- Prevent liquids from splashing or dripping onto the device. Make sure there are no liquid-filled objects on the device, to prevent liquid from entering it.
- Do not disassemble the device.
Installation Requirements
- Before switching on, connect the device to the power adapter.
- Strictly comply with local electrical safety standards and make sure the voltage in the area is stable and matches the device's power requirements.
- Do not connect the device to more than one power source. Otherwise, the device could be damaged.
- When working at heights, follow all safety procedures and use the required protective equipment.
- Do not expose the device to direct sunlight or heat sources.
- Do not install the device in damp, dusty, or smoky locations.
- Install the device in a well-ventilated location and do not block its ventilation.
- Use the power adapter or power supply provided by the device manufacturer.
- The power supply must meet the ES1 requirements of IEC 62368-1 and must not exceed PS2. The power supply requirements are governed by the device's rating label.
- Connect Class I electrical appliances to a socket with protective earthing.
Functional Elements
- LED indicator (green) – indicates pairing, alarm, and test results (see Signaling).
- Ext. input connector – for connecting the connecting cable of a wired external detector.
- Power switch (ON/OFF) – turns the device on and off.
- Tamper contact – triggers an alarm when the rear cover is opened or the detector is removed from the mounting plate.
- Magnet – a separate module attached to the moving part of the door/window or to the frame; moving it closer to or away from the detector controls the reed relay.
The detector is installed on the fixed part of the window or door frame, and the magnet on the moving part (the sash). The arrangement can also be reversed – what matters is the relative position of the two modules in the closed state.
Operating Principle
Door Guard Plus is a sophisticated security device consisting of two key components: a detector with an integrated, highly reliable reed relay capable of up to 2 million opening cycles, and a strong permanent magnet. In addition to the reed switch, the detector also contains a three-axis accelerometer for detecting shocks and changes in tilt angle.
Magnetic contact
The operating principle is based on the magnetic field – as soon as the magnet moves away from the detector, the reed switch activates and an opening alarm is triggered. The actual distance at which the alarm is triggered depends on the relative orientation of the two modules (the axis of separation/approach) and has been verified by testing according to EN 50131-2-6:
| Axis / sample | Event | Air gap distance (declared = verified) |
|---|---|---|
| 1 (Y) | Separation / approach | 34 mm / 28 mm |
| 2 (X+) | Separation / approach | 20 mm / 18 mm |
| 3 (X-) | Separation / approach | 20 mm / 18 mm |
| 4 (Z+) | Separation / approach | 46 mm / 40 mm |
| 5 (Z-) | Separation / approach | 46 mm / 39 mm |
Vibration and shock detection
The built-in three-axis accelerometer can detect vibrations or impacts that may indicate an attempted forced entry or tampering with the magnetic contact. The alarm is triggered if the intensity of the shock exceeds the set sensitivity level (high / medium – default / low). This function can be supplemented with the option Ignore first vibration – if the interval between two shocks is shorter than 1 second, the alarm is triggered; otherwise, the alarm does not occur. We recommend enabling this option in installation environments prone to shocks (e.g., at entrance gates).
Tilt and position change detection
The accelerometer also detects changes in the vertical tilt angle. The alarm is triggered if the tilt of the detector exceeds the configured tilt angle (5 / 10 / 15 / 20 / 25°, default 5°) and the tilted state lasts longer than the configured tilt alarm delay (1–60 s, default 2 s). This allows the detector to also be used for monitoring the tilting or removal of paintings, safes, or other valuable items.
External wired input
Door Guard Plus is equipped on the rear side with one potential-free input (1× NC/NO, configurable, or pulse), which is used to connect an external wired detector using the supplied connecting cable. This input allows easy integration of additional security elements, including third-party devices – for example a flammable or explosive gas detector, an armored contact for gates, a flood detector, or another wired magnetic contact operating on the normally closed/open circuit principle. This function significantly increases the flexibility and expands the modular capabilities of the entire SAFE security system.
SAFE Keeper protocol
Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:
- AES-128 encryption with a rolling code,
- frequency hopping as protection against interference – upon detecting interference, the system notifies the user and automatically retunes to an interference-free frequency band,
- range up to 1 200 m in open space,
- regular connection checks – the system immediately reports any detector outage.
Adding to the System
Before adding the device
- Install the app ProSAFE and log in to your account.
- Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
- The hub must be in the Disarmed state.
How to add Door Guard Plus
- In the ProSAFE app, open your hub and click Device.
- Click + Add device.
- Scan the QR code with the serial number on the detector and click Next.
- Once the device is found, click Next.
- Following the on-screen instructions, turn on the detector by switching the power switch to position ON and click Next.
- Wait for pairing to complete – successful pairing is confirmed by the LED lighting up for 2 seconds.
- Enter the detector name, select the area (zone), and click Done.
States
You can view the current detector status in the ProSAFE app by selecting the detector in the Devices list.
| Parameter | Meaning |
|---|---|
| Temporarily disable | Detector functional status
|
| Temperature | Current ambient temperature measured by the integrated sensor |
| Signal strength | Radio signal level: none / low / weak / good / excellent |
| Battery status | Full / sufficient / medium / insufficient / low |
| Tamper status | Indicates that the detector has been removed from the mounting plate or that the rear cover has been opened |
| Connection status | Online – the detector is communicating / Offline – loss of connection |
| Entry / exit delay | The configured delay times for entering and exiting the zone |
| Door detector status | Open / closed |
| External input | Status of the connected external wired detector (after the external device configuration has been enabled) |
| 24-hour zone | Enabled / disabled – detection independent of the system's arming status |
| Transmission via repeater | Whether the detector communicates with the hub via a signal repeater |
| Firmware version | Current detector firmware version |
Settings
You can change the settings in the ProSAFE app: select the detector in the Devices list and click the edit icon.
| Settings | Value |
|---|---|
| Device configuration | Displaying the name, type, serial number, and model; editing the device name |
| Area (zone) | Assigning the detector to a system area |
| Zone number | The zone number assigned to the detector's alarm – cannot be configured |
| Temporarily disable | Enable (default) – the detector is fully functional
|
| LED indicator | On (default) / off – when off, the LED does not light up regardless of the device's status |
| 24-hour zone | A device in a 24-hour protection zone is always active, regardless of the system's arming status |
| Home Armed mode | When the system is partially armed, the detector is activated only if Home Armed mode is enabled for it |
| Home Armed mode delay | Enabling the delay activates the selected device in Home Armed mode only after the configured time has elapsed
|
| Entry / exit delay | Entry delay max. 45 s (according to EN 50131-1), exit 0–120 s; the system's arming becomes effective only after the delay has elapsed |
| Door detector configuration | Enabling / disabling the alarm when the door is opened by the detector |
| External device configuration | Enabling / disabling the external input; once enabled, its status is displayed
|
| Vibration detector configuration | Enabling / disabling shock detection
|
| Tilt detector configuration | Enabling / disabling tilt detection
|
| Chime | When enabled, opening the door while the system is disarmed triggers an audible chime signal from the indoor siren |
| Temperature detection | Alarm when the set temperature range (min/max) is exceeded |
| Transmission power | High / low / automatic – higher power extends the range and increases consumption
|
| Signal strength test | Verification of the radio connection quality at the installation site |
| Detection test | Verification of device functionality |
| Cloud update | Remote firmware update |
| Remove device | Deleting the detector from the system (swipe left in the Devices list) |
Signaling
| LED indication | Event |
|---|---|
| Fast green blinking | Pairing mode, or reduced-sensitivity mode (low transmission power) |
| Lights up green for 2 s | Successful pairing with the hub |
| Slow green blinking for 3 s | Pairing failed |
| Continuously lit green | An alarm was triggered (opening, shock, tilt, or tamper) |
| Off | The LED indicator is turned off in the settings, or the device is switched off |
Choosing the installation location
Mount the detector on the fixed part of the door or window frame, and the magnet on the moving part (the sash), so that in the closed state both modules are as close together as possible and on the same axis. Orient the opening for connecting the external input's connecting cable according to the cabling requirements.
Signal strength
Before final installation, test the signal strength in the app (Signal strength test). The recommended minimum value is 2 bars. If the signal is weak, move the detector or use a signal repeater.
Where not to install the detector and magnet
- On metal doors and window frames, or in their immediate vicinity – metal weakens the magnetic field and reduces the reliability of detection as well as the range of the radio signal. The detector is primarily designed for non-metallic doors and windows.
- In locations outside the declared range of operating temperature and humidity (the device is intended for indoor installation).
- In locations exposed to excessive vibrations unrelated to an intrusion attempt (e.g., near machinery) – this increases the risk of false shock detection alarms; in such cases, reduce the sensitivity or enable the Ignore First Vibration function.
- In locations with a weak hub radio signal.
Detector installation
Both modules – the detector and the magnet – can be attached in two ways: quickly using double-sided adhesive tape, or with screws using the included mounting kit, if the installation requires security grade 2 according to ČSN EN 50131.
Mounting using the mounting kit (screws, security grade 2)
- Assemble the parts of the mounting kit as shown in the figure and attach them with screws to the fixed part of the frame (detector) and to the moving part of the door/window (magnet).
- Place the detector body, or the magnet, onto the mounting plate by sliding it in the direction of the arrow.
Mounting using double-sided adhesive tape
- Clean and degrease the installation location on both the frame and the door/window sash.
- Attach the mounting plate to the surface using the included double-sided adhesive tape.
- Place the device onto the mounting plate by sliding it in the direction of the arrow.
Functionality Test
After installation, verify the correct function of the detector:
- Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
- Detection test – open and close the door/window and verify that the app registered the change of state.
- Shock detection test – if the function is enabled, gently shake the door/window and verify that, according to the configured sensitivity, the alarm is triggered.
- Tilt detection test – if the function is enabled, tilt the protected object by the configured angle for longer than the configured delay, and verify that the alarm is triggered.
- Tamper test – remove the detector from the mounting plate or open the rear cover, and verify that a tamper notification was received in the app.
Battery replacement
The detector is powered by 1× CR123A lithium battery (3 H) with a lifespan of up to 4 years when the external input NO is activated (2 years for the external input NC or pulse), assuming the alarm is triggered twice a day with a battery efficiency of 70 %. The battery is inserted at the factory, so the device can be used immediately. The ProSAFE app will notify you of a low battery.
- Remove the detector from the mounting plate and turn it off using the power switch.
- Open the rear cover – press the latch that holds the cover.
- Replace the battery. Observe the correct polarity – the side marked "+" must face the rear cover.
- Close the rear cover, turn on the device using the switch, setting it to position ON and return it to the mounting plate.
Maintenance
- Check the relative position and gap between the detector and the magnet, especially after adjusting or replacing the door/window.
- Regularly check the battery status and signal strength in the ProSAFE app.
- Perform a detection test again after every manipulation of the detector or magnet.
- If an external wired detector is connected, regularly check the condition of the cabling and its functionality.
- Do not disassemble the detector or the magnet, and protect them from corrosive and staining liquids.
Technical Specifications
| Detection parameters | |
| Detection type | Magnetic, position change |
| Sensor | Three-axis accelerometer, reed contact |
| Detection range (gap) | <40 mm |
| Recommended door/window type | Non-metallic |
| Shock detection | Adjustable, 3 levels |
| Tilt detection | Up to 25° |
| Temperature sensor | |
| Measuring range | −15 °C to +65 °C (indoor environments) |
| Accuracy / resolution | ±1 °C / 1 °C |
| Inputs / outputs | |
| Alarm input | 1× NC/NO potential-free (configurable, incl. pulse) |
| Wireless transmission – SAFE Keeper | |
| Carrier frequency | 868,0–868,6 MHz |
| Transmitter power (EIRP) | limit 25 mW |
| Communication distance | Up to 1 200 m in open space |
| Communication type | Two-way |
| Encryption | AES-128 |
| Frequency hopping | Yes (automatic) |
| Interface and functions | |
| Indication | 1× green LED |
| Control Devices | 1× power switch |
| Tamper | Yes (tamper contact) |
| Remote update | Yes (cloud) |
| Low battery notification | Yes |
| Test mode | Yes (signal strength test, detection test) |
| General | |
| Power supply | 1× CR123A battery, 3 V |
| Power consumption | Max. 125 mW |
| Current draw | ≤ 12 µA (operation) / ≤ 2,3 mA (alarm) |
| Battery life | When activated 2× daily, battery efficiency 70 %: 4 years (ext. input NO) / 2 years (ext. input NC or pulse) |
| Operating temperature | −10 °C to +55 °C (indoor environments) |
| Operating humidity | 10–90 % RH |
| Housing material | PC + ABS |
| Color | White (SAFE 38110) / black (SAFE 38111) |
| Product dimensions | 100.2 × 20.8 × 20.3 mm |
| Package dimensions | 135.0 × 98.5 × 27.8 mm |
| Weight | 70 g net / 115 g gross |
| Installation | On mounting plate (adhesive tape, or screws for security grade 2) |
| Compatibility | Hub 2 Plus LTE (SAFE 38300), hub firmware v1.001.0000005.0.R.221230 or newer, ProSAFE app v1.99.400 or newer |
| Certification | CE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-6:2017; EN 50131-5-3:2017; EN 50131-2-6:2008; Security grade 2; Environmental class II |
Package Contents
- Door Guard Plus (detector + magnet) – 1 set
- Double-sided adhesive tape – 2 pcs
- Connecting cable (ext. input) – 1 pcs
- Quick user guide – 1 pcs
- Legal and regulatory information – 1 pcs
- Mounting kit (screws) – 1 set
- QR code with the user manual – 1 pcs
Safety Notices
- Make sure the device's power supply is in order before use, and operate the device only within its rated range.
- Do not let liquids drip or splash onto the device, and make sure no containers filled with liquid are placed on it.
- Keep batteries out of the reach of children. Do not throw batteries into fire or a hot oven, crush them, or cut them open – risk of explosion. Do not expose the battery to extremely high temperatures or extremely low air pressure. If battery ingestion is suspected, seek medical attention immediately.
- Replace depleted batteries only with a battery of the same type and model (CR123A).
- Do not dispose of the product with regular household waste – hand it in for recycling through the electrical equipment take-back system.
Warranty
The SAFE Door Guard Plus device is covered by a warranty 36 months from the date of sale. The warranty does not cover the battery or defects caused by failure to follow the instructions in this manual.
If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.
Gallery
Need Help?
SAFE HOME europe technical support:
Email: info@safe-home.eu · Phone: (+420) 581 222 262
Website: www.smart-safe.eu