Indoor Siren is a wireless indoor siren intended for indoor use, offering 3 volume intensity levels, 3 signaling tone types, and an adjustable duration for the audible alarm signal. Among other things, the siren also signals the entry and exit delay. The siren features an integrated LED indicator and a function for announcing the system's arming/disarming.

84 dBsound pressure (high volume, 1 m)
1 000 mradio signal range
2,5 yearsbattery life
3alarm tone types
3volume levels
Grade 2security grade according to EN 50131
3 volume levels and 3 types of audible alarm signaling
Radio signal range up to 1000 m
Cloud-based device firmware update
Integrated LED indicator
Smart bracket for quick and easy installation
Security grade 2 according to ČSN EN 50131
Up to 5 years of battery operation
Tamper protection against sabotage and unauthorized manipulation of the device
Adding the device to the system by scanning a QR code
Integrated temperature sensor
Two-way information transfer between devices
Protection against radio signal interference
Simple device installation

Preface

General

This user manual describes the installation, functions, and operation of the wireless indoor siren (hereinafter referred to as the "siren"). Before using the device, please read this manual carefully and keep it for future reference.

Safety Instructions

The following signal words may appear in the user manual:

Signal WordMeaning
DANGERIndicates a high potential hazard that, if not avoided, may result in death or serious injury.
WARNINGIndicates a medium or low potential hazard that could cause minor or moderate injury if not avoided.
CAUTIONIndicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome.
TIPProvides methods to help you solve a problem or save time.
NOTEProvides additional information, such as emphasis and supplementary text.

Revision History

VersionRevision ContentRelease Date
V1.0.0First release.August 2026

Privacy Notice

As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the Manual

Important Safeguards and Warnings

This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.

Operating Requirements

CAUTION

Installation Requirements

WARNING
CAUTION

Functional Elements

Functional elements of the siren: inner side (1 power switch, 2 tamper contact) and front side (3 LED indicator)
Functional elements of the siren: inner side (1 power switch, 2 tamper contact) and front side (3 LED indicator)
  1. Power switch (ON/OFF) – turns the device on and off.
  2. Tamper (tamper contact) – triggers an alarm when the siren is released from the mounting plate.
  3. LED indicator (green) – indicates pairing, alarm, arming, and test results (see Signaling).
  4. Speaker – the source of the audible alarm signal.
  5. Rear cover / mounting plate – used to attach the siren to the chosen surface.

Operating Principle

Indoor Siren is a key element of the SAFE security system that significantly increases its effectiveness and ensures an immediate response to unauthorized entry into the premises. The alarm can be triggered, for example, by an intrusion into an area monitored by a PIR motion sensor, by breaking a window or door protected by a magnetic open detector, and so on. The audible signal is generated at a level that is considerably unpleasant for humans – it reliably warns of impending danger, discourages a potential intruder from proceeding further, and at the same time attracts the attention of those nearby.

Audible alarm signaling

The siren offers three different types of warning tones, which can be easily adapted to the specific alarm signal defined by the connected devices of the security system – for example, a warning of unauthorized intrusion, or the risk of fire or flooding in the monitored area. An audible tone is not always suitable for all types of events, so the ProSAFE app allows siren signaling for selected operations to be simply disabled.

Arming and disarming signaling

The siren can accompany the security system states with sound and light:

Tamper and siren sabotage signaling

The siren is equipped with a Tamper function that protects the device against sabotage or unauthorized manipulation. If the siren is released from the mounting panel or its cover is opened, the system immediately evaluates a tamper alarm and the user receives a notification in the ProSAFE app – siren sabotage signaling.

SAFE Keeper protocol

Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:

Adding to the System

Adding a device by scanning a QR code (example)
Adding a device by scanning a QR code (example)

Before adding the device

  1. Install the app ProSAFE and log in to your account.
  2. Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
  3. The hub must be in the Disarmed state.
App version 1.91 or later and hub firmware 1.001.0000000.0.R.210303 or later are required. Full functionality of the “Temporarily disable” state and transmission via a repeater requires app version 1.96 or later, hub firmware 1.001.0000000.6.R.211215 or later, and siren firmware 1.000.0000001.0.R.20211216 or later.

How to add the Indoor Siren

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the bottom of the siren and tap Next.
  4. Once the siren is found, tap Next.
  5. Following the on-screen instructions, turn on the siren by switching the power switch to position ON and click Next.
  6. Wait for pairing to complete – successful pairing is confirmed by the LED lighting up for 2 seconds.
  7. Enter a name for the siren, select an area (zone), and tap Done.
If pairing fails (the LED blinks slowly for 3 s), check that the hub is online and in the Disarmed state, and repeat the procedure.

States

You can view the current status of the siren in the ProSAFE app by selecting the siren in the device list.

ParameterMeaning
Online statusConnection between the siren and the hub
  • Online – the siren is communicating
  • Offline – loss of connection
Signal strengthRadio signal level: none / low / weak / good / excellent
Battery levelFull / sufficient / medium / insufficient / low
Tamper statusSiren sabotage signaling – responds to the siren being released from the mounting panel
TemperatureCurrent ambient temperature measured by the integrated sensor
Temporarily disableSiren function state (tri-state)
  • Enable – siren functions enabled
  • Disable tamper alarm only
  • Disable – siren functions completely switched off
VolumeSet volume level of the alarm signal
Alarm durationSet duration of the audible alarm signaling
Arming indicationWhen enabled, the siren indicates the arming of the area with an indicator and a sound signal
Entry/exit delay toneSound tone when entering or exiting the protected area and when arming/disarming
Transmission via repeaterWhether the siren forwards messages from other hub devices via a signal repeater
Firmware versionCurrent siren firmware version

Settings

You can adjust the settings in the ProSAFE app: select the siren in the device list and tap the edit icon.

SettingsValue
Device nameCustom name for the siren; displayed in the device list and in notifications
Area (zone)Assignment of the siren to the system area it is to guard
Temporarily disableTri-state switch for siren functions
  • Enable – siren functions enabled (default)
  • Disable tamper alarm only
  • Disable – siren functions completely switched off
LED indicatorOn (default) / off – when off, the LED does not light up regardless of the device's status
Area permissionsSelection of the area over which the siren has control authority
Sound settingsAlarm volume (low / medium / high); entry and exit delay tone; alarm sound selection (sound 1–3, default sound 1)
Alarm durationDuration of the audible alarm signaling: 3–120 s
Arming indicationWhen enabled, the LED flashes green every 3 s for the duration the area is armed
Transmission powerHigh / low / automatic – higher power extends the range and increases consumption
  • Low power switches the siren into reduced sensitivity mode
Signal strength testVerification of the radio connection quality at the installation site
Speaker testRunning the test verifies the volume of the alarm signal
Cloud updateRemote firmware update
Remove deviceDeleting the siren from the system (swipe left in the device list)

Signaling

LED indicationEvent
Fast green blinkingPairing mode, or reduced-sensitivity mode (low transmission power)
Flashes green every secondAn alarm has been triggered
Lights up green for 2 sSuccessful pairing with the hub
Slow green blinking for 3 sPairing failed
Flashes green every 3 sArming indication – the area is armed
OffThe LED indicator is turned off in the settings, or the device is switched off

Choosing the installation location

Indoor Siren is intended exclusively for indoor spaces. Place it so that it is clearly audible throughout the building and its surroundings, for example in the central part of the house, in a hallway, or in an entrance hall.

Signal strength

Before final installation, test the signal strength in the app (Signal strength test). The recommended minimum value is 2 bars. If the signal is weak, move the siren or use a signal repeater.

Where not to install the siren

  1. In places exposed to direct sunlight or near heat sources.
  2. In damp, dusty, or smoky areas.
  3. In places with limited air circulation where the siren's speaker would be blocked.
  4. In locations with a weak hub radio signal.
  5. Outdoors or in areas that do not meet the indoor operating conditions (−10 °C to +55 °C, 10–90 % RH).

Siren installation

The siren can be mounted on the selected surface in two ways – using double-sided adhesive tape (included in the package) or by screwing the mounting panel using screws and wall plugs from the mounting kit. Before drilling, we recommend temporarily placing the siren at the installation site and performing a signal strength test.

Removing the insulation strips from the siren in the direction of the arrows
Remove the insulation strips from the siren in the direction of the arrows
  1. Remove the insulation strips from the siren in the direction of the arrows.
  2. If the siren body is fitted too tightly onto the mounting panel, first remove the back cover using a screwdriver.
Removing the siren's back cover using a screwdriver
Removing the back cover – always use a screwdriver, the cover must not be removed by force
  1. Mounting with adhesive tape – attach the mounting panel to the selected surface using double-sided adhesive tape.
    Mounting with screws – drill 2 holes according to the holes on the mounting panel, insert the wall plugs, and screw the panel to the wall.
Drilling 2 holes into the wall and inserting wall plugs with screws for the mounting panel
Mounting with screws: drill 2 holes and insert wall plugs with screws
  1. Fit the siren body onto the mounting panel in the direction of the arrow and secure it in the panel by turning the device.
Fitting the siren onto the mounting panel and turning to secure it
Fitting the siren onto the mounting panel and turning to secure it
The siren body must not be fitted too tightly onto the back cover. When removing the cover, always use a screwdriver – this will prevent damage to the securing tabs.

Functionality Test

After installation, verify the correct function of the siren:

  1. Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
  2. Speaker test – in the siren settings, run the test and verify the volume and sound of the alarm signal.
  3. Tamper test – carefully release the siren from the mounting panel and verify that a sabotage alert (siren sabotage signaling) was received in the app.

Battery replacement

The siren is powered by 2× CR123A lithium batteries (3 H) with a lifespan of up to 2,5 years (with 2 alarms per week and a signaling duration of 120 s). The ProSAFE app will alert you to a low battery.

  1. Remove the siren from the mounting panel by turning the device and switch it off using the switch to position OFF.
  2. Open the back cover by loosening the screw on the back.
  3. Remove the old battery and insert a new CR123A battery. Observe the correct polarity.
  4. Close the back cover and tighten the screw.
  5. Turn on the device using the switch, setting it to position ON.
  6. Fit the siren back onto the mounting panel and secure it by turning.
Replace the battery only with a battery of the same type (CR123A). Do not throw used batteries into fire, do not crush or cut them, and keep them out of reach of children – risk of explosion or serious injury if swallowed.

Maintenance

Technical Specifications

Interface and functions
Indication1× green LED
Control Devices1× power switch
TamperYes (tamper contact)
Remote updateYes (cloud)
SearchSignal strength detection
Test modeYes
Low battery warningYes
Temperature sensor
Measuring range−15 °C to +65 °C (indoor spaces); certified range −10 °C to +40 °C
Accuracy / resolution±1 °C / 1 °C
Acoustic parameters
Sound pressure84 dB at a distance of 1 m (high volume) / 78 dB at a distance of 1 m (medium volume)
Volume setting3 levels
Alarm signaling3 types of tones, adjustable duration 3–120 s
Wireless transmission – SAFE Keeper
Carrier frequency868,0–868,6 MHz
Transmitter power (EIRP)limit 25 mW
Communication distanceUp to 1 000 m in open space
Communication typeTwo-way
EncryptionAES-128 with rolling code
Frequency hoppingYes (automatic)
General
Power supply2× CR123A batteries, 3 V (included in the package)
Power consumptionMax. 240 mW
Current drawOperation ≤9 µA; alarm ≤100 mA
Battery lifeUp to 2,5 years (at 2 alarms per week, signaling duration 120 s)
Operating temperature−10 °C to +55 °C (indoor environments)
Operating humidity10–90 % RH
Product dimensions81 × 81 × 26 mm
Package dimensions137 × 98 × 57 mm
Weight (net / gross)105 g / 189,5 g
Housing materialPC + ABS, white
InstallationOn mounting plate (adhesive tape or screws)
CompatibilityHub 2 Plus LTE (SAFE 38300)
CertificationCE; EN 50131-1; EN 50131-4; EN 50131-5-3; EN 50131-6; Security grade 2; Environmental class II
Siren dimensional drawing: 80,9 × 80,9 × 26 mm
Siren dimensions (mm)

Package Contents

Indoor Siren package contents
  1. Indoor Siren – 1 pcs
  2. Double-sided adhesive tape – 1 pcs
  3. Mounting panel – 1 pcs
  4. Mounting kit (screws, wall plugs) – 1 set
  5. QR code with the user manual – 1 pcs
  6. Quick user guide – 1 pcs
  7. Legal and regulatory information – 1 pcs

Safety Notices

Warranty

The SAFE Indoor Siren device is provided with a warranty 36 months from the date of sale. The warranty does not cover batteries or defects caused by failure to follow the instructions in this manual.

If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.

Gallery

Need Help?

SAFE HOME europe technical support:
Email: info@safe-home.eu  ·  Phone: (+420) 581 222 262
Website: www.smart-safe.eu