Outdoor Siren is a wireless siren designed for outdoor use, offering 3 volume intensity levels, 3 types of signaling tones, and an adjustable duration interval for the audible alarm signaling. The siren includes a group of 12 LEDs providing intense and bright visual alarm signaling. High resistance to weather conditions.
Preface
General
This user manual introduces the installation, functions, and operation of the wireless outdoor siren (hereinafter referred to as the “siren”). Before using the device, read the manual carefully and keep it for future reference.
Safety Instructions
The following signal words may appear in the user manual:
| Signal Word | Meaning |
|---|---|
| DANGER | Indicates a high potential hazard that, if not avoided, may result in death or serious injury. |
| WARNING | Indicates a medium or low potential hazard that could cause minor or moderate injury if not avoided. |
| CAUTION | Indicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome. |
| TIP | Provides methods to help you solve a problem or save time. |
| NOTE | Provides additional information, such as emphasis and supplementary text. |
Revision History
| Version | Revision Content | Release Date |
|---|---|---|
| V1.0.0 | First release. | August 2026 |
Privacy Notice
As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.
About the Manual
- The user manual serves as a reference guide only. There may be minor differences between the information provided and the product.
- We are not liable for any damage resulting from using the product in a manner that does not comply with the instructions in the user manual.
- The manual will be updated according to the latest laws and regulations of the relevant jurisdictions. For detailed information, refer to the printed user manual, scan the QR code, or visit our official website. The manual is for reference purposes only. There may be minor differences between the electronic and paper versions.
- All designs and software are subject to change without prior written notice. Due to product updates, certain differences may occur between the product and the information in the manual. Customer service will provide you with the latest version of the software and supplementary documentation.
- There may be printing errors or discrepancies in the description of functions, operations, and technical data. In the event of doubt or dispute, we reserve the right of final explanation. If the manual (in PDF format) cannot be opened, update your reader software or try a different common reader software.
- All trademarks, registered trademarks, and company names in the manual are the property of their respective owners.
- If you encounter any problems while using the device, visit our website or contact your supplier or customer service.
- In the event of ambiguity or dispute, we reserve the right of final explanation.
Important Safeguards and Warnings
This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.
Operating Requirements
- Before use, make sure the device's power supply is working properly.
- Do not unplug the device's power cable while it is switched on.
- Use the device only within its rated power range.
- Transport, use, and store the device within the permitted humidity and temperature conditions.
- Prevent liquids from splashing or dripping onto the device. Make sure there are no liquid-filled objects on the device, to prevent liquid from entering it.
- Do not disassemble the device.
Installation Requirements
- Before switching on, connect the device to the power adapter.
- Strictly comply with local electrical safety standards and make sure the voltage in the area is stable and matches the device's power requirements.
- Do not connect the device to more than one power source. Otherwise, the device could be damaged.
- When working at heights, follow all safety procedures and use the required protective equipment.
- Do not expose the device to direct sunlight or heat sources.
- Do not install the device in damp, dusty, or smoky locations.
- Install the device in a well-ventilated location and do not block its ventilation.
- Use the power adapter or power supply provided by the device manufacturer.
- The power supply must meet the ES1 requirements of IEC 62368-1 and must not exceed PS2. The power supply requirements are governed by the device's rating label.
- Connect Class I electrical appliances to a socket with protective earthing.
Functional Elements
- Waterproof cover – protects the siren's internal electronics from water and dust.
- Spirit level – allows you to verify that the siren is horizontal during installation.
- Tamper contact – triggers an alarm when the siren is removed from the mounting panel or the cover is opened.
- Buzzer – source of the loud audible alarm signaling.
- Battery compartment – 4× CR123A batteries installed according to the marked polarity.
- Pairing indicator (green LED) – indicates the progress and result of pairing with the hub (see Signaling).
- Power terminal 12 V DC – used to connect an optional external power cable 12 V DC.
- Power cable outlet – grommet for feeding in the power cable 12 V DC into the siren's cover.
- Alarm indicator – flashes rapidly when an alarm event is triggered.
- Power switch (ON/OFF) – turns the siren on and off.
Operating Principle
Outdoor Siren is an outdoor wireless siren of the SAFE security system, used to provide audible and visual alerts of any attempt to breach the protected area. When installed on the outside shell of a building, it acts as a strong deterrent for potential intruders. Combined with outdoor PIR detectors or IP cameras, it can effectively deter an intruder even before an actual attack or breach of the protected perimeter occurs.
The siren responds to alarm messages sent by the hub from other system devices and also serves to signal the entry and exit delay or the arming and disarming of the system.
Visual and audible alarm signaling
The siren emits an extremely loud audible signal with an intensity of up to 110 dB at a distance of 1 m, complemented by a distinctive visual alert thanks to 12 powerful LEDs. Visual signaling combined with an intense audible alarm not only effectively informs the surroundings of the emergency event but, in most cases, also deters the intruder from further action.
Multi-level audible alarm signaling
The siren offers various types of warning signaling that can be easily adapted to the specific alarm signal defined by the connected security system elements – for example, an unauthorized intrusion alert, panic alarm, fire alarm, or medical assistance call. In the ProSAFE app, the audible signaling can be simply disabled for selected events if it is not suitable for the given situation.
Sabotage protection
The siren has a tamper contact that protects the device against unauthorized manipulation. If an intruder attempts to remove the siren, forcibly open its cover, or otherwise disrupt its function, the siren immediately triggers an alarm accompanied by siren sabotage signaling – an audible and visual alarm identical to normal alarm signaling.
SAFE Keeper protocol
Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:
- AES-128 encryption,
- frequency hopping as protection against jamming – when signal jamming is detected, the user is alerted and the system automatically switches to an interference-free frequency band,
- range up to 1 600 m in open space,
- two-way communication and regular connection checks – the system immediately reports a siren failure.
External power supply 12 V DC
In addition to standard battery power, the siren can optionally be powered from an external source 12 V DC (the power cable is not included in the package). External power saves the batteries and allows the use of additional LED indication of alarm and arming status (see Signaling). The external power connection can be supplemented in the app with the function External power detection, which alerts you to a failure of the 12 V DC.
Adding to the System
Before adding the siren
- Install the app ProSAFE and log in to your account.
- Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
- The hub must be in the Disarmed state.
How to add the Outdoor Siren
- In the ProSAFE app, open your hub and click Device.
- Click + Add device.
- Scan the QR code with the serial number on the bottom of the siren and tap Next.
- Once the siren is found, tap Next.
- Following the on-screen instructions, turn on the siren by switching the power switch to position ON and click Next.
- Wait for pairing to complete – successful pairing is confirmed by the LED lighting up for 2 seconds.
- Enter a name for the siren, select an area (zone), and tap Done.
States
You can view the current status of the siren in the ProSAFE app by selecting the siren in the device list.
| Parameter | Meaning |
|---|---|
| Temporarily disable | Siren functionality status
|
| Temperature | Current ambient temperature measured by the integrated sensor |
| Signal strength | Radio signal level between the hub and the siren: none / low / weak / good / excellent |
| External power status | Connected / disconnected – alarm for failure of the 12 V DC |
| Battery level | Full / sufficient / medium / insufficient / low |
| Tamper status | Signals the siren being removed from the mounting panel or the cover being opened |
| Online status | Connection between the siren and the hub
|
| Volume | Set volume level of the audible alarm |
| Alarm duration | Set duration of the audible alarm signaling |
| Entry/exit ring tone when arming and disarming | Ring tone assigned to the entry and exit delay |
| Beep volume | High / medium / low |
| Transmission via repeater | Whether the siren forwards hub device messages via a signal repeater |
| Firmware version | Current siren firmware version |
Settings
You can adjust the settings in the ProSAFE app: select the siren in the device list and tap the edit icon.
| Settings | Value |
|---|---|
| Device name | Custom name for the siren; displayed in the device list and in notifications |
| Area (zone) | Assignment of the siren to a system area |
| Temporarily disable | Allow (default) / Disable tamper alarm only / Disable |
| Area permissions | Selection of areas whose alarm will trigger signaling by this siren |
| External power detection | Enabling the sending of alarm messages to the app in the event of a failure of the 12 V DC |
| LED indicator | On (default) / off – when off, the LED does not light up regardless of the device's status |
| Sound settings | Alarm volume (low / medium / high); enabling or disabling beeping during arming, disarming, and entry/exit delay |
| Alarm duration | Adjustable from 3 to 80 s |
| Alarm status signaling | The LED lights up when an alarm occurs in an armed area; if the area has not been disarmed and the alarm ended less than 30 s ago, the LED flashes 2× per minute |
| Beep volume | High / medium / low |
| Signal strength test | Verification of the radio connection quality at the installation site |
| Speaker test | By tapping Start test you can verify the volume of the audible alarm |
| Transmission power | High / low / automatic – higher power extends the range and increases consumption |
| Cloud update | Remote firmware update |
| Remove device | Deleting the siren from the system (swipe left in the device list) |
Signaling
| LED indication | Event |
|---|---|
| Fast green blinking | Pairing with the hub in progress |
| Lights up green for 2 s | Successful pairing with the hub |
| Slow green blinking for 3 s | Pairing failed |
| The alarm indicator flashes rapidly | An alarm has been triggered – audible and visual signaling |
| Blue flashing once every 3 s | The system is armed (only when powered from an external 12 V DC) |
| Red flashing twice per minute | The alarm was triggered and has not been cleared for a certain period (only when powered from an external 12 V DC) |
| Off | The LED indicator is turned off in the settings, or the device is switched off |
Choosing the installation location
Install the siren in a clearly visible and audible location on the outside shell of the building so that the audible and visual signal alerts the widest possible surrounding area to the alarm. Choose a location that makes it difficult for an intruder to access the siren and attempt sabotage – ideally at a height beyond normal reach.
Signal strength
Before final installation, test the signal strength in the app (Signal strength test). The recommended minimum value is 2 bars. If the signal is weak, move the siren or use a signal repeater.
Where not to install the siren
- In places exposed to direct sunlight or near heat sources.
- In damp, dusty, or smoky areas.
- In locations with a weak hub radio signal.
- In easily accessible places that facilitate unauthorized manipulation of the siren (e.g., low above the ground, near a window or balcony).
- In recesses, under canopies, or behind other obstacles that dampen the sound spreading to the surroundings.
Siren installation
Before mounting, turn on the siren, connect it to the hub, and verify the signal strength at the intended installation location – we recommend installing the siren in a location with a signal strength of at least 2 bars.
- Loosen the screw at the bottom of the siren and remove the front cover.
- Place the back panel in a horizontal position – use the built-in spirit level to verify that the siren is level and horizontal.
- Insert the wall plugs (included in the package) into the drilled holes.
- Position the back panel so that the screw holes are aligned with the wall plugs.
- Secure the back panel with three ST4 × 25 mm.
- Fit the front cover back on and tighten the screw at its bottom – this secures the siren against removal.
Functionality Test
After installation, verify the correct function of the siren:
- Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
- Speaker test – by tapping Start test verify the volume of the audible alarm at the installation site.
- Tamper test – after completing the installation, carefully try to lift the front cover and verify that a sabotage alert was received in the app.
Power supply and battery replacement
The siren can be powered by 4× CR123A lithium batteries (3 V, default) with a lifespan of up to 3,4 years (with activation once every 2 weeks and a signaling duration of 120 s), or optionally from an external source 12 V DC. The ProSAFE app will warn you of a low battery.
- Loosen the screw at the bottom and remove the siren's front cover.
- Open the waterproof cover of the battery compartment.
- Set up the power supply according to the selected type:
- Battery power: insert 4 CR123A batteries according to the marked polarity.
- 12 V DC power (optional): feed the 12 V DC power cable into the cover through the power cable outlet and connect it to the power terminal.
- Close the waterproof cover.
- Turn on the device using the power switch to the ON.
- Fit the front cover back on and tighten the securing screw.
Maintenance
- Keep the siren cover clean – wipe off dust and dirt with a dry soft cloth. Do not use aggressive cleaning agents.
- Check that neither the front cover nor the waterproof cover is damaged and that the siren remains properly sealed.
- Regularly check the battery status and signal strength in the ProSAFE app.
- After each manipulation of the siren, perform the signal strength test and the speaker test again.
- Do not disassemble the siren and protect it from corrosive and staining liquids.
Technical Specifications
| Audible and visual signaling | |
| Sound pressure | 110 dB at a distance of 1 m |
| Volume setting | 3 levels |
| Alarm duration | 3 to 80 s |
| Visual signaling | 12× group of alarm LEDs |
| Pairing indication | 1× green LED |
| Temperature sensor | |
| Measuring range | −30 °C to +70 °C (outdoor spaces) |
| Accuracy / resolution | ±1 °C / 1 °C |
| Wireless transmission – SAFE Keeper | |
| Carrier frequency | 868,0–868,6 MHz |
| Transmitter power (EIRP) | limit 25 mW |
| Communication distance | Up to 1 600 m in open space |
| Communication type | Two-way |
| Encryption | AES-128 |
| Frequency hopping | Yes (automatic) |
| Interface and functions | |
| Control Devices | 1× power switch |
| Tamper | Yes (tamper contact) |
| Remote update | Yes (cloud) |
| Signal strength detection | Yes |
| External power detection | Yes |
| Low battery notification | Yes |
| Test mode | Signal strength test, speaker test |
| General | |
| Power supply | 4× CR123A batteries, 3 V (default, included in the package); 12 V DC (optional) |
| Power consumption | Max. 240 mW |
| Current draw | ≤92 µA (operation), ≤1 A (alarm) |
| Battery life | 3,4 years (with activation once every 2 weeks and signaling duration of 120 s, battery efficiency 80 %) |
| Operating temperature | −25 °C to +60 °C |
| Operating humidity | 10–90 % RH |
| Ingress protection rating | IP65 |
| Housing material | PC + ABS |
| Color | White + red |
| Product dimensions | 200 × 200 × 52,5 mm (L × W × H) |
| Package dimensions | 256 × 242 × 64 mm (L × W × H) |
| Weight (net) | 610 g |
| Weight (gross) | 965,4 g |
| Installation | Wall |
| Compatibility | Hub 2 Plus LTE (SAFE 38300); app v1.96 or later; hub firmware v1.001.R.211209 or later |
| Certification | CE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-4:2019; EN 50131-6:2017; EN 50131-5-3:2017; Security grade 2; Environmental class IV |
Package Contents
- Outdoor Siren – 1 pcs
- CR123A batteries – 4 pcs
- Mounting kit – 1 set
- Quick user guide – 1 pcs
- Legal and regulatory information – 1 pcs
- QR code with the user manual – 1 pcs
Safety Notices
- Do not install the device in places exposed to direct sunlight or near heat sources; install it in a well-ventilated location and do not block its ventilation.
- When using 12 V DC power, use only a power supply provided or recommended by the manufacturer, meeting the ES1 requirements according to IEC 62368-1 (max. PS2 level), and comply with local electrical safety regulations.
- Keep batteries out of reach of children. Do not throw batteries into fire, do not crush or cut them – risk of explosion. If battery ingestion is suspected, seek medical help immediately.
- Replace discharged batteries only with batteries of the same type (CR123A).
- Do not dispose of the product with regular household waste – hand it in for recycling through the electrical equipment take-back system.
Warranty
The SAFE Outdoor Siren device is provided with a warranty 36 months from the date of sale. The warranty does not cover batteries or defects caused by failure to follow the instructions in this manual.
If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.
Gallery
Need Help?
SAFE HOME europe technical support:
Email: info@safe-home.eu · Phone: (+420) 581 222 262