Product Manuals / Integration and automation

Wireless input module for wired detectors compatible with the ProSAFE app
SAFE Input Board (SAFE 38180)

User Manual

Updated 20. 8. 2026

Product Page Datalist (PDF)
The SAFE Input Board wireless input module

Input Board allows any third-party wired components with an NC/NO type output to be connected to the SAFE security system. It ensures reliable transmission of alarm and tamper signals via an encrypted protocol SAFE Keeper, thereby expanding the system's capabilities without the need to replace existing devices.

6terminals for wiring
1 600 mradio signal range
5 yearsbattery life
3,3 Vauxiliary power (max. 10 mA)
Grade 2security according to ČSN EN 50131
AES128encryption with rolling code
Integration of devices with a wired output into the SAFE system
Adjustable wired input of NC / NO type
Output for powering the connected wired device
Radio signal range up to 1600 m
Cloud-based device firmware update
Data encryption using the AES algorithm with rolling code
Two-way information transfer between devices
Automatic retuning to an interference-free channel
Protection against radio signal interference
Built-in LED indicator
Wide range of permissible operating temperature and humidity
Tamper protection against sabotage and unauthorized manipulation of the device
Up to 5 years of battery operation
Adding the device to the system by scanning a QR code

Preface

General

This user manual introduces the installation, functions, and operation of the wireless input module for wired detectors (hereinafter referred to as the “module”). Before using the device, read the manual carefully and keep it for future reference.

Safety Instructions

The following signal words may appear in the user manual:

Signal WordMeaning
DANGERIndicates a high potential hazard that, if not avoided, may result in death or serious injury.
WARNINGIndicates a medium or low potential hazard that could cause minor or moderate injury if not avoided.
CAUTIONIndicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome.
TIPProvides methods to help you solve a problem or save time.
NOTEProvides additional information, such as emphasis and supplementary text.

Revision History

VersionRevision ContentRelease Date
V1.0.0First release.August 2026

Privacy Notice

As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the Manual

Important Safeguards and Warnings

This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.

Operating Requirements

CAUTION

Installation Requirements

WARNING
CAUTION

Functional Elements

Input Board functional elements – numbered diagram of the board
Input Board functional elements
  1. On/Off switch – turns the module on (upper position) and off (lower position).
  2. Power output (+ / −) – two auxiliary power terminals 3,3 V, max. 10 mA, for the connected wired device.
  3. Alarm input (ALARM) – two terminals forming a loop for connecting the output of a wired detector (NO / NC / Pulse).
  4. Tamper input (TAMP) – two terminals forming a loop for connecting the tamper contact of the wired device.
  5. Indicator – 1 × green LED indicating the module's status and alarm.
  6. Battery compartment – 3 × CR123A batteries, pre-installed at the factory and protected by a mylar strip.
The module is additionally equipped with a built-in triaxial accelerometer, which detects movement (removal) of the module itself, even without a connected tamper input.

Operating Principle

Input Board serves as a converter between a third-party wired security device and the wireless SAFE system. As soon as the connected external device (wired detector, button, sensor, etc.) triggers an alarm or tamper event on its output, the module converts this signal and wirelessly sends it to the hub via its built-in RF module. The hub then evaluates the alarm, sends a notification to the app ProSAFE and, in configured cases, also to the central monitoring station (DPPC).

The module can handle a wide range of wired peripheral devices from various manufacturers – from classic PIR motion sensors, through opening detectors, glass break detectors, and emergency buttons, to specialized gas or water leak sensors.

Integration of existing wired elements

Input Board allows already installed wired detectors and sensors to be incorporated into the SAFE system without having to invest in their complete replacement. The module can be placed directly inside the cover of the connected third-party device or in a separate installation box.

Configurable reception of alarm events

The system's behavior when an alarm is triggered at the input is set in the ProSAFE app separately for each Input Board. Up to seven categories of alarm events are available, covering the most common security incidents: intrusion, fire, medical assistance, SOS, gas leak, water leak and sabotage attempt of the system. By combining the Home mode, Delay, and 24-hour zone settings, you can further determine the type of input zone – instant, delayed, interior, or permanently monitored.

Protection against manipulation and sabotage

The module's security is further enhanced by a built-in triaxial accelerometer, which reliably detects sabotage attempts – it can distinguish even subtle movements and vibrations caused by unauthorized manipulation of the module. A separate tamper input additionally allows monitoring of the tamper contact of the connected third-party device.

SAFE Keeper protocol

Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:

Adding to the System

Adding a device by scanning a QR code
Adding a device by scanning a QR code

Before adding the device

  1. Install the app ProSAFE and log in to your account.
  2. Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
  3. The hub must be in the Disarmed state.
For full functionality (parameters Temporarily disable, Transmission via repeater and Transmission power) app version 1.99.420 or later and hub firmware V1.001.0000006.0.R.230404 or later are required. For basic addition of the module, app v1.99.200 and hub v1.001.0000003.0.R.220819 or later are sufficient.

How to add the Input Board to the hub

  1. Open the hub in the ProSAFE app and tap Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the bottom of the module and tap Next.
  4. Once the module is found, tap Next.
  5. Following the on-screen instructions, turn on the module by switching the switch to position ON and click Next.
  6. Wait for pairing to complete.
  7. Enter a name for the module, select an area (zone), and tap Done.
Add the module to the system before the final installation – after connecting it to the hub, verify the signal strength at the installation site (see Choosing the installation location) and only then mount the module and connect the wired device.

Terminal wiring

The module's screw terminal block contains a total of 6 wires divided into three pairs: power output, alarm input, and tamper input.

Detail of the Input Board's screw terminal block with the + − ALARM TAMP terminals
Module terminal block: + − (power) · ALARM (alarm input) · TAMP (tamper input)
TerminalWiring description
+ / −Auxiliary power output – 3,3 V DC, max. 10 mA. Used to power the connected wired device (e.g., a PIR sensor or glass break detector) directly from the module's battery. The output mode (always on / off when disarmed / always off) is set in the app – see Settings.
ALARMAlarm input – a pair of terminals forming a loop. Connect the normally open (NO), normally closed (NC), or pulse output of the wired detector to it. The input type (Normally Open / Normally Closed / Pulse) and the alarm type (intrusion, fire, medical assistance, SOS, gas leak, water leak) are set in the ProSAFE app under the item External input.
TAMPTamper input – a pair of terminals forming a loop for the tamper contact of the connected wired device (e.g., its housing cover). This function must be activated in the module settings under the item External tamper contact and select the NO/NC contact type.
Input Board may only be installed by a qualified electrician (installation technician), regardless of the type of electrical circuit to which the connected device is attached. Follow all safety standards and regulations during installation. Otherwise, there is a risk of electric shock, fire, or damage to the equipment. To minimize these risks, work only with the device disconnected from the mains!
Input Board should be placed inside the cover of the connected third-party device. The module requires a space with minimum dimensions of 105 × 40 × 30 mm. If it is not possible to install the module inside the device's cover, use a suitable installation box with an appropriate ingress protection rating, made of a material that does not absorb radio waves.

States

You can view the current status of the module in the ProSAFE app by selecting the Input Board in the hub's device list.

ParameterMeaning
Online statusConnection between the module and the hub
  • Online – the module is communicating
  • Offline – loss of connection
Temporarily disableEnable – the module sends alarm and tamper information to the hub / Disable – it does not send it
Signal strengthRadio signal level: none / low / weak / good / excellent
Battery levelFull / sufficient / medium / insufficient / low
External device tamper statusStatus of the TAMP terminal – on / off
TemperatureCurrent ambient temperature measured by the module's integrated sensor
External inputWhether the ALARM input is functioning normally or is in an error state
Motion detectionWhether the module's motion detection function (accelerometer) is enabled
24-hour zoneEnabled / disabled – detection independent of the system's arming status
Entry / exit delayThe configured delay times for entry and exit
Transmission via repeaterWhether the module communicates with the hub via a signal repeater
Chime statusOn / off – for door input applications
Firmware versionCurrent firmware version of the module

Settings

You can change the settings in the ProSAFE app: select Input Board in the hub's device list and tap the edit icon.

SettingsValue
Device configurationDisplays the module's name, type, serial number, and model; edit and save the name
Area (zone)Assigning the module to a system area
Zone numberZone number assigned to the alarm input – cannot be configured
Temporarily disableEnable (default) – the module sends alarm and tamper information to the hub / Disable – it does not send it
LED indicatorOn (default) / off – when off, the LED does not light regardless of the module's status
24-hour zoneOn – the module monitors even when the system is disarmed
  • Off – the module monitors only when the system is armed
  • Arming does not take effect immediately, but only within the hub–module communication interval (default 60 s, adjustable on the hub)
Home modeIncluding the module in the partial (home) arming of selected devices
Home mode delayDelayed arming within home mode; requires Home mode to be enabled
DelayEntry delay max. 45 s (according to EN 50131-1), exit 0–120 s
Siren linkageThe siren sounds when this input triggers an alarm
Video linkageLinking an alarm event to a video channel (channel selection)
External inputAlarm type (intrusion, fire, medical assistance, SOS, gas leak, water leak) and ALARM input type: NO / NC / Pulse
External tamper contactEnabling the function and selecting the TAMP contact type: NO / NC
Motion detectionThe module checks its own movement (accelerometer) every 5 s; if the acceleration threshold is exceeded, it triggers an alarm and the LED indicator flashes
  • Siren linkage can be enabled only when motion detection is on
External power supplyAlways on – the module always powers the connected device
  • Off when disarmed – the +/− output is switched off when the system is disarmed
  • Always off – the module never powers the external device
  • Continuous power supply shortens battery life; the supported voltage is 3.3 V
ChimeWhen enabled, it triggers the internal siren while the area is disarmed if the connected door contact is open
Unusual temperature alarmAlarm when the set temperature range (min/max) is exceeded
Signal strength testVerification of the radio connection quality at the installation site
Detection testVerifying the functionality of the module and the connected input
Transmission powerHigh / low / automatic – higher power extends the range and increases consumption
  • When Low is selected, the module switches to reduced sensitivity mode and the LED indicator flashes
  • Recommended to set Low during the signal test at the installation site, then switch to High or Automatic
Cloud updateRemote firmware update
Remove deviceRemoving the module from the system (swipe left in the device list)

Signaling

LED indicationEvent
FlashingTransmission power is set to Low (reduced sensitivity mode)
FlashingA motion alarm has been triggered (accelerometer detection)
OffThe LED indicator is disabled in settings, or the module is switched off
Monitor the module's detailed current status (signal strength, battery status, tamper) in the ProSAFE app – see States.

Choosing the installation location

The Input Board is placed inside the enclosure of the connected third-party wired device, or in a separate installation box. The module requires a space with minimum dimensions of 105 × 40 × 30 mm.

Signal strength

Before final installation, test the signal strength in the app (Signal strength test) directly at the location where the module will be installed. If the signal is weak, relocate the module, increase the transmission power, or use a signal repeater.

Where not to install the module

  1. Into metal enclosures or cabinets that shield the radio signal.
  2. Into an installation box made of material that absorbs radio waves (metal, carbon composites, etc.) – use a box made of material that does not absorb radio waves.
  3. In damp, dusty, or smoky areas.
  4. In places exposed to direct sunlight or near heat sources.
  5. In locations with a weak hub radio signal.

Module installation

The module is supplied with 3 pre-installed CR123A batteries protected by a mylar strip, and 8 spacers of two heights (4 + 4 pcs) for supporting the board.

  1. Attach 4 spacers into the holes in the module's board.
  2. Mount the Input Board on a flat surface inside the enclosure of the connected device or in the installation box.
  3. Remove the mylar strip from the battery compartment – this activates the module's power supply.
  4. Add the module to the hub in the ProSAFE app (see Adding to the System) and check the signal strength at the installation site.
  5. Complete the wiring of all 6 terminals (see Terminal wiring).
  6. Switch the On/Off switch to verify that the module is working.
Attaching the spacers to the Input Board module's board
Attaching the spacers to the module's board
Removing the mylar strip from the Input Board module's battery compartment
Removing the mylar strip from the battery compartment

Functionality Test

After installation and wiring, verify the module is functioning correctly:

  1. Signal strength test – run a test in the app and verify the quality of the radio connection with the hub.
  2. Detection test – trigger an alarm on the connected wired device (e.g., open the ALARM loop) and verify that the ProSAFE app recorded the corresponding event.
  3. Tamper test – open the TAMP loop (or remove the cover of the connected device) and verify that a tamper alert was received.
  4. Motion alarm test – if the function is enabled, move the module and verify that the LED indicator flashes and a motion alarm appears in the app.
Detection testing is activated within the module's communication interval with the hub (default 60 s) – wait a while after starting the test.

Battery replacement

The module is powered by 3 × CR123A lithium batteries with a lifespan of up to 5 years (without continuous power supply to an external device). The ProSAFE app will notify you of a low battery.

  1. Disconnect the module from the connected wired device and remove it from the installation site.
  2. Remove the old batteries and insert 3 new CR123A batteries. Observe the correct polarity according to the markings on the board.
  3. Return the module to the installation site and reconnect all terminals.
  4. Switch the power switch to position ON verify functionality and check the battery level in the app.
Always replace all 3 batteries at the same time, and use only batteries of the same type and model (CR123A). Do not dispose of batteries in fire or a hot oven, and do not crush or cut them – risk of explosion. Do not expose batteries to extremely high temperatures or extremely low air pressure – risk of explosion or leakage of flammable liquid and gas. Keep batteries out of reach of children. If a battery is suspected to have been swallowed, seek medical help immediately.

Maintenance

Technical Specifications

Interface
Indication1× green LED
Button1× power button (switch)
Alarm input1× NO / NC / Pulse
Tamper input1× tamper
Power output3.3 V, up to 10 mA
Function
Tamper contactTriaxial accelerometer
Configurable alarm typesIntrusion, fire, medical assistance, SOS, gas leak, water leak
Remote updateYes (Cloud)
SearchSignal strength detection
Temperature sensorYes – measuring range −10 °C to +55 °C (indoor)
Low battery warningYes
Anti-corrosion levelYes (basic protection)
Wireless transmission – SAFE Keeper
Carrier frequency868.0–868.6 MHz
Transmitter power (EIRP)limit 25 mW
Communication distanceUp to 1,600 m in open space
Communication typeTwo-way
EncryptionAES128
Frequency hoppingYes (automatic)
General
Power supply3× CR123A batteries (included)
Current drawStandby: 45 µA; alarm: 50 mA (avg.)
Power consumptionMax. 150 mW (without powering external devices)
Battery lifeUp to 5 years (without powering external devices)
Operating temperature−10 °C to +55 °C (indoor environment)
Operating humidity10–90 % RH
Product dimensions102 × 39 × 21.5 mm
Package dimensions95 × 43 × 139 mm
Weight (net)77 g
Weight (gross)135 g
InstallationMounting in an installation box or inside a third-party device (min. space 105 × 40 × 30 mm)
ClassificationModule for integrating third-party wired devices into the SAFE system
ApplicationIndoor / outdoor environment (depending on the ingress protection of the chosen installation box)
CompatibilityHub 2 Plus LTE (SAFE 38300), hub v1.001.0000003.0.R.220819 or later, app v1.99.200 or later
CertificationCE; EN 50131-1:2006+A1:2009+A2:2017+A3:2020; EN 50131-3:2009; EN 50131-6:2017+A1:2021; EN 50131-5-3:2017; Security grade 2 / Environmental class II
Model DesignationSAFE 38180 (ARM320-W2(868))
EAN code0728204234945
Dimensional drawing of the Input Board module: 102 × 39 × 21.5 mm
Dimensions of the Input Board module (mm)

Package Contents

Contents of the Input Board module package
  1. Input Board – 1 pcs
  2. Spacers – 8 pcs
  3. Quick user guide – 1 pcs
  4. Legal and regulatory information – 1 pcs
  5. QR code with the user manual – 1 pcs

Safety Notices

Warranty

The SAFE Input Board device is covered by a warranty of 36 months from the date of sale. The warranty does not cover batteries or defects caused by failure to follow the instructions in this manual or incorrect installation of connected third-party wired devices.

If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.

Gallery

Need Help?

SAFE HOME europe technical support:
Email: info@safe-home.eu  ·  Phone: (+420) 581 222 262
Website: www.smart-safe.eu