Dry Relay is a modern wireless relay with a potential-free output, designed for convenient and safe remote control of electrical equipment and appliances with power supply in the range of 7 to 24 V DC. Thanks to the NO/NC relay output (normally open/normally closed contact), which is galvanically isolated from the power circuit, maximum safety and universal use (a "dry contact") is ensured. The output can be easily configured either in bistable mode for permanent switching on or off, or in pulse mode, in which the relay switches on only for a preset duration.
Preface
General
This user manual describes the installation, functions, and operation of the wireless relay with potential-free contact (hereinafter referred to as the "relay"). Before using the device, read this manual carefully and keep it for future reference.
Safety Instructions
The following signal words may appear in the user manual:
| Signal Word | Meaning |
|---|---|
| DANGER | Indicates a high potential hazard that, if not avoided, may result in death or serious injury. |
| WARNING | Indicates a medium or low potential hazard that could cause minor or moderate injury if not avoided. |
| CAUTION | Indicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome. |
| TIP | Provides methods to help you solve a problem or save time. |
| NOTE | Provides additional information, such as emphasis and supplementary text. |
Revision History
| Version | Revision Content | Release Date |
|---|---|---|
| V1.0.0 | First release. | August 2026 |
Privacy Notice
As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.
About the Manual
- The user manual serves as a reference guide only. There may be minor differences between the information provided and the product.
- We are not liable for any damage resulting from using the product in a manner that does not comply with the instructions in the user manual.
- The manual will be updated according to the latest laws and regulations of the relevant jurisdictions. For detailed information, refer to the printed user manual, scan the QR code, or visit our official website. The manual is for reference purposes only. There may be minor differences between the electronic and paper versions.
- All designs and software are subject to change without prior written notice. Due to product updates, certain differences may occur between the product and the information in the manual. Customer service will provide you with the latest version of the software and supplementary documentation.
- There may be printing errors or discrepancies in the description of functions, operations, and technical data. In the event of doubt or dispute, we reserve the right of final explanation. If the manual (in PDF format) cannot be opened, update your reader software or try a different common reader software.
- All trademarks, registered trademarks, and company names in the manual are the property of their respective owners.
- If you encounter any problems while using the device, visit our website or contact your supplier or customer service.
- In the event of ambiguity or dispute, we reserve the right of final explanation.
Important Safeguards and Warnings
This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.
Operating Requirements
- Before use, make sure the device's power supply is working properly.
- Do not unplug the device's power cable while it is switched on.
- Use the device only within its rated power range.
- Transport, use, and store the device within the permitted humidity and temperature conditions.
- Prevent liquids from splashing or dripping onto the device. Make sure there are no liquid-filled objects on the device, to prevent liquid from entering it.
- Do not disassemble the device.
Installation Requirements
- Before switching on, connect the device to the power adapter.
- Strictly comply with local electrical safety standards and make sure the voltage in the area is stable and matches the device's power requirements.
- Do not connect the device to more than one power source. Otherwise, the device could be damaged.
- When working at heights, follow all safety procedures and use the required protective equipment.
- Do not expose the device to direct sunlight or heat sources.
- Do not install the device in damp, dusty, or smoky locations.
- Install the device in a well-ventilated location and do not block its ventilation.
- Use the power adapter or power supply provided by the device manufacturer.
- The power supply must meet the ES1 requirements of IEC 62368-1 and must not exceed PS2. The power supply requirements are governed by the device's rating label.
- Connect Class I electrical appliances to a socket with protective earthing.
Functional Elements
- Antenna – transmits and receives the radio signal.
- LED indicator (green) – indicates pairing and device status (see Signaling).
- Power button – press and hold for 2 seconds to start pairing; holding it again for 2 seconds switches the device off (it enters standby mode).
- Wiring terminal block – used to connect the power supply, tamper loop, and controlled circuit (see Installation).
Operating Principle
Dry Relay is a wireless relay with a potential-free (dry) output contact of NO/NC type, which is used for remote control of the power supply to the connected device in the range of 0–36 V DC. The output contact is galvanically isolated from the relay's power circuit, which ensures maximum safety and universal use – the relay can therefore reliably simulate the function of a button or switch in electrical circuits with different voltages, for example in sirens, electric valves, or electromagnetic locks.
Switches are controlled either directly by the user's command via the app ProSAFE, or automatically according to a configured scene.
Bistable and pulse output mode
The relay output can be set to bistable mode (permanent switching on or off of the contact) or to pulse mode, in which the relay switches on only for a preset duration (pulse duration) and then automatically returns to its default state. The default setting is pulse mode with an NC (normally closed) contact.
Scenes for automation and switch control
Scenes can be used to program actions that respond to alarm events or operate according to a preset schedule. Scenes can be created and configured remotely directly in the ProSAFE app:
- Arm/disarm linkage scene – after naming the scene and selecting the linked area, you can turn linkage with arming, disarming, or Home Armed mode on or off.
- Alarm linkage scene – the relay reacts to a selected alarm event in the system.
- Scheduled scene – after naming the scene and enabling scheduled linkage, you can set the trigger time and repeat period.
The device is therefore ideal not only for alarm installations, but also offers full integration of the SAFE security system into a smart home or building automation – wherever safe wireless control of devices powered by a low voltage of 7 to 24 V DC using a relay is needed.
Overvoltage and overheating protection
The Dry Relay device is equipped with advanced overvoltage and overheating protection.
SAFE Keeper protocol
Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:
- AES-128 encryption,
- frequency hopping as protection against interference – when signal interference is detected, the user is notified and the device automatically retunes to an interference-free frequency band,
- range up to 1 200 m in open space,
- two-way transmission of information between devices.
Adding to the System
Before adding the device
- Install the app ProSAFE and log in to your account.
- Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
- The hub must be in the Disarmed state.
How to add Dry Relay
- In the ProSAFE app, open your hub and click Device.
- Click + Add device and scan the QR code with the relay's serial number, then tap Next.
- Once the relay is found, tap Next.
- Connect the relay to the power supply according to the instructions in chapter Terminal wiring and press and hold the power button for 2 seconds – the device enters pairing mode. Tap Next.
- Wait for pairing to complete – successful pairing is confirmed by the LED: it lights up for 1 second, turns off for 0.5 seconds, and then remains permanently lit.
- Enter the relay name, select an area (zone), and tap Done.
States
You can view the current relay status in the ProSAFE app by selecting the relay in the device list.
| Parameter | Meaning |
|---|---|
| Temporarily disable | Relay functionality status
|
| Signal strength | Radio signal level: none / low / weak / good / excellent |
| Input voltage | Current value of the supply voltage applied to the relay's terminals |
| Output status | Current status of the relay output (on / off) |
| Online status | Connection between the relay and the hub
|
| Transmission via repeater | Whether the relay communicates with the hub via a signal repeater |
| Firmware version | Current firmware version of the relay |
Settings
You can change the settings in the ProSAFE app: select the relay in the device list and tap the edit icon.
| Settings | Value |
|---|---|
| Device name | Custom relay name; shown in the device list and in notifications |
| Area (zone) | Assigning the relay to a system area |
| Temporarily disable | Enable (default) – the relay sends messages to the hub / Disable – it does not send them |
| Output type | NO (normally open) / NC (normally closed) – default NC |
| Output mode | Bistable (permanent on/off) / Pulse (default)
|
| LED indicator | On (default) / off – when off, the LED does not light regardless of the device's functional status |
| Scenes | Creating a scene that links the relay with the corresponding action – linkage with system (dis)arming, alarm linkage, or a scheduled scene (see Operating Principle) |
| External tamper contact | When enabled, a tamper alarm is activated from the TAMPER terminal |
| Transmission power | High / low / automatic
|
| Signal strength test | Verifying the current radio signal strength at the installation site |
| Cloud update | Remote firmware update |
| Remove device | Removing the relay from the system (swipe left in the device list) |
Signaling
| LED indication | Event |
|---|---|
| Fast green blinking | Pairing mode, or reduced-sensitivity mode (low transmission power) |
| Lit for 1 s, turns off for 0.5 s, then stays permanently lit | Successful pairing with the hub |
| Slow green blinking for 3 s, then turns off | Pairing failed |
| Off | The LED indicator is disabled in settings, or the device is not powered |
Installation
Location
Thanks to its miniature dimensions (39×33×19 mm), the relay can be placed in a deep installation (flush-mounted) box, inside the enclosure of an electrical appliance, or in a distribution board. The relay can also be attached to a surface using the included double-sided adhesive tape, or to a DIN rail using the SAFE DIN Holder bracket. Before final mounting, add the relay to the system and test the signal strength at the installation site – the recommended minimum value is 2 bars.
Terminal wiring
| Terminal | Description |
|---|---|
| PS | Positive (+) pole of the relay power supply |
| IN | Negative (–) pole of the relay power supply |
| TAMPER | Input terminal for the NO/NC tamper loop for an external device – if the loop is broken or shorted, the relay triggers a tamper alarm |
| RELAY | Potential-free (dry) NO/NC relay output – the controlled circuit of the connected device, switched by closing/opening the built-in relay |
- Disconnect the power supply and prepare the wires according to the wiring diagram.
- Insert the wires into the terminal block and secure them by tightening the screws. Observe the marked power supply polarity (PS = +, IN = –).
- The relay can be connected to a power source in the range of 6.5–36.5 V DC.
- Optionally, connect an external tamper loop to the TAMPER terminal and the controlled circuit to the RELAY terminal.
Mounting
- After verifying the signal strength and wiring the terminals, attach the relay to the selected surface using double-sided adhesive tape, or place it in an installation box, appliance enclosure, or distribution board.
- Connect the relay to the power supply and add it to the system (see Adding to the System), if you have not already done so.
- Perform a functionality test (see below).
Functionality Test
After installation, verify the relay is functioning correctly:
- Signal strength test – run a test in the app and verify that the signal reaches at least 2 bars.
- Relay output test – switch the relay on and off in the ProSAFE app and verify that the connected device (siren, lock, valve, etc.) responds correctly.
- Tamper test – if you are using the TAMPER terminal, break or short-circuit the loop and verify that a tamper alert was received in the app.
Maintenance
- Keep the relay dry, dust-free, and away from heat sources and direct sunlight.
- Regularly check that the terminal block screws are tight and check the condition of the connected wires.
- Regularly check the signal strength and relay status in the ProSAFE app.
- After any intervention in the wiring, repeat the relay output test and the signal strength test.
- Do not disassemble or modify the relay.
Technical Specifications
| Interface | |
| Indication | 1× green LED |
| Button | 1× power button |
| Alarm input | 1× tamper, NO/NC |
| Relay output | 1× NO/NC (0–36 V DC, max. 5 A) |
| Function | |
| Remote update | Yes (cloud) |
| Search | Signal strength detection |
| Test mode | Yes |
| Wireless transmission – SAFE Keeper | |
| Carrier frequency | 868.0–868.6 MHz |
| Transmitter power (EIRP) | limit 25 mW |
| Communication distance | Up to 1,200 m in open space |
| Communication type | Two-way |
| Encryption | AES-128 |
| Frequency hopping | Yes (automatic) |
| General | |
| Power supply | 7–24 V DC |
| Operating temperature | −10 °C to +55 °C (indoor environment) |
| Storage temperature | −10 °C to +55 °C |
| Operating / storage humidity | 10–90 % RH |
| Product dimensions | 39 × 33 × 19 mm |
| Package dimensions | 95 × 59.5 × 30.5 mm |
| Weight (net) | 45 g |
| Weight (gross) | 60 g |
| Housing material | PC + ABS |
| Color | White |
| Installation | Wall mounting, or in an installation box |
| Compatibility | Hub 2 Plus LTE (SAFE 38300) |
| Certification | CE |
Package Contents
- Dry Relay – 1 pcs
- Double-sided adhesive tape – 1 pcs
- QR code with serial number – 1 pcs
- Quick user guide – 1 pcs
- Legal and regulatory information – 1 pcs
Safety Notices
- Before installation and use, read this manual carefully and keep it for future reference.
- Installation and wiring may only be carried out by a person with appropriate electrical qualification (installer) in accordance with local regulations and electrical safety standards.
- Before wiring, check that the power supply is functional and meets the required parameters (7–24 V DC). Operate the device only within the rated range of the power supply and relay output.
- Do not disconnect the device's power cable while it is live. Do not connect the device to more than one power source at the same time.
- The power supply must meet SELV (safety extra-low voltage) requirements according to IEC 60950-1 / IEC 62368-1 standards, category ES1, power class max. PS2 – use only the adapter recommended by the manufacturer.
- Connect Class I electrical appliances only to a socket with protective earthing.
- The relay output is intended exclusively for switching low voltage up to 36 V DC / max. 5 A – never connect it directly to a 230 V AC mains voltage.
- Transport, use, and store the device only within the permitted temperature and humidity range (−10 °C to +55 °C, 10–90% RH, indoor environment).
- Protect the device from dripping and splashing water; do not place objects filled with liquid on or near it.
- Do not expose the device to direct sunlight or heat sources. Do not install it in a damp, dusty, or smoky environment. Install it in a well-ventilated location and do not block its ventilation.
- Do not disassemble or modify the device – in case of a fault, contact technical support.
- Do not dispose of the product with regular household waste – hand it in for recycling through the electrical equipment take-back system.
Warranty
The SAFE Dry Relay device is covered by a warranty of 36 months from the date of sale. The warranty does not cover defects caused by failure to follow the instructions in this manual, in particular failure to observe the rated parameters of the power supply and relay output.
If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.