Water Guard is a very small and compact water leak detector with a 2 in 1 design, which offers two types of installation right away – suitable both against slow seepage and against a sudden flooding of the monitored area, where protecting the detector from being submerged or washed away is important.
Preface
General
This user manual describes the installation, functions, and operation of the wireless water leak detector (hereinafter referred to as the “detector”). Before using the device, read this manual carefully and keep it for future reference.
Safety Instructions
The following signal words may appear in the user manual:
| Signal Word | Meaning |
|---|---|
| DANGER | Indicates a high potential hazard that, if not avoided, may result in death or serious injury. |
| WARNING | Indicates a medium or low potential hazard that could cause minor or moderate injury if not avoided. |
| CAUTION | Indicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome. |
| TIP | Provides methods to help you solve a problem or save time. |
| NOTE | Provides additional information, such as emphasis and supplementary text. |
Revision History
| Version | Revision Content | Release Date |
|---|---|---|
| V1.0.0 | First release. | August 2026 |
Privacy Notice
As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.
About the Manual
- The user manual serves as a reference guide only. There may be minor differences between the information provided and the product.
- We are not liable for any damage resulting from using the product in a manner that does not comply with the instructions in the user manual.
- The manual will be updated according to the latest laws and regulations of the relevant jurisdictions. For detailed information, refer to the printed user manual, scan the QR code, or visit our official website. The manual is for reference purposes only. There may be minor differences between the electronic and paper versions.
- All designs and software are subject to change without prior written notice. Due to product updates, certain differences may occur between the product and the information in the manual. Customer service will provide you with the latest version of the software and supplementary documentation.
- There may be printing errors or discrepancies in the description of functions, operations, and technical data. In the event of doubt or dispute, we reserve the right of final explanation. If the manual (in PDF format) cannot be opened, update your reader software or try a different common reader software.
- All trademarks, registered trademarks, and company names in the manual are the property of their respective owners.
- If you encounter any problems while using the device, visit our website or contact your supplier or customer service.
- In the event of ambiguity or dispute, we reserve the right of final explanation.
Important Safeguards and Warnings
This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.
Operating Requirements
- Before use, make sure the device's power supply is working properly.
- Do not unplug the device's power cable while it is switched on.
- Use the device only within its rated power range.
- Transport, use, and store the device within the permitted humidity and temperature conditions.
- Prevent liquids from splashing or dripping onto the device. Make sure there are no liquid-filled objects on the device, to prevent liquid from entering it.
- Do not disassemble the device.
Installation Requirements
- Before switching on, connect the device to the power adapter.
- Strictly comply with local electrical safety standards and make sure the voltage in the area is stable and matches the device's power requirements.
- Do not connect the device to more than one power source. Otherwise, the device could be damaged.
- When working at heights, follow all safety procedures and use the required protective equipment.
- Do not expose the device to direct sunlight or heat sources.
- Do not install the device in damp, dusty, or smoky locations.
- Install the device in a well-ventilated location and do not block its ventilation.
- Use the power adapter or power supply provided by the device manufacturer.
- The power supply must meet the ES1 requirements of IEC 62368-1 and must not exceed PS2. The power supply requirements are governed by the device's rating label.
- Connect Class I electrical appliances to a socket with protective earthing.
Functional Elements
- LED indicator (green) – indicates binding, alarm, and sensitivity test mode (see Signaling).
- Negative probes – a pair of fixed contacts on the bottom of the device for detecting water.
- Positive probe – a height-adjustable contact used to set the detection sensitivity.
- Power switch – turns the device on and off.
Operating Principle
Water Guard detects a water leak using three contact probes on the bottom of the device – two fixed negative probes and one height-adjustable positive probe. As soon as the water level reaches the probes, the circuit between them closes and the detector immediately sends an alarm event to the hub. The user then immediately receives a notification in the ProSAFE.
Water leak detection using 3 contacts
High sensitivity thanks to three special contact probes ensures the detector immediately detects even the smallest water leak – whether it is slow seepage or a sudden flooding of the monitored area.
Adjustable detection sensitivity
The height of the positive probe can be continuously adjusted by turning it. Turning it clockwise moves the probe closer to the floor and increases the detection sensitivity (even a small amount of water will trigger an alarm). Turning it counterclockwise decreases the sensitivity.
Automatic alarm cancellation once the water drains away
Once the water drains away from the probes or dries up and the circuit opens, the detector automatically ends the alarm state and sends information about the return to normal status to the ProSAFE app.
Unusual temperature alarm
The integrated temperature sensor measures the ambient temperature at the installation site with an accuracy of ±1 °C. The settings allow you to define minimum and maximum temperature limits – if they are exceeded, the detector triggers an alarm, and once the temperature returns to the set range, it sends information about the return to normal conditions. This function is useful, for example, for detecting a floor heating failure.
2-in-1 housing design
The unique housing allows the detector to be simply placed freely on the floor at a location where there is a risk of water leakage, or it can be split apart – only the compact sensor with three contacts then remains on the floor, while the detector body with the electronics is securely mounted higher up on the wall or on the mounting panel, out of reach of any sudden flooding or being washed away.
SAFE Keeper protocol
Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:
- AES128 data encryption with a rolling code,
- frequency hopping as protection against interference,
- range up to 1 200 m in open space,
- two-way communication between the detector and the hub.
Adding to the System
Before adding the device
- Install the app ProSAFE and log in to your account.
- Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
- The hub must be in the Disarmed state.
How to add Water Guard
- In the ProSAFE app, open your hub and click Device.
- Click + Add device.
- Scan the QR code with the serial number on the bottom of the detector and click Next.
- Once the detector is found, click Next.
- Following the on-screen instructions, turn on the detector by switching the power switch and click Next.
- Wait for pairing to complete – successful pairing is confirmed by the LED lighting up for 2 seconds.
- Enter the detector name, select the area (zone), and click Done.
States
You can view the current detector status in the ProSAFE app by selecting the detector in the Devices list.
| Parameter | Meaning |
|---|---|
| Online status | Connection between the detector and the hub
|
| Signal strength | Radio signal level: none / low / weak / good / excellent |
| Battery level | Full / sufficient / medium / insufficient / low |
| Water leak status | Normal / Alarm |
| Temporarily disable | Enable – the detector sends alarm messages to the hub / Disable – it does not |
| Transmission via repeater | Whether the detector communicates with the hub via a signal repeater |
| Firmware version | Current detector firmware version |
Settings
You can change the settings in the ProSAFE app: select the detector in the Devices list and click the edit icon.
| Settings | Value |
|---|---|
| Device name | Custom detector name; shown in the device list and in notifications |
| Area (zone) | Assigning the detector to a system area |
| Temporarily disable | Enable (default) – the detector sends alarm messages to the hub / Disable – it does not |
| LED indicator | On (default) / off – when off, the LED does not light up regardless of the device's status |
| Siren linkage | The siren sounds when this detector triggers an alarm |
| Video linkage | When an alarm occurs, the selected video channel is linked and the alarm video is saved |
| Video channel | Selection of the video channel to link with the alarm |
| Temperature detection | Alarm when the set temperature range (min/max) at the installation site is exceeded |
| Transmission power | High / low / automatic – higher power extends the range and increases consumption
|
| Signal strength test | Verification of the radio connection quality at the installation site |
| Detection test | Verifying detector functionality |
| Cloud update | Remote firmware update |
| Remove device | Deleting the detector from the system (swipe left in the Devices list) |
Signaling
| LED indication | Event |
|---|---|
| Fast green blinking after pressing and holding the button for 2 s | Turning on the device and entering binding mode |
| Lights up green for 2 s | Successful pairing with the hub |
| Slow green blinking 3 times | Pairing failed |
| Fast green blinking for 100 s, then turns off | Sensitivity test mode |
| Briefly lights up green (0.4 s) | Water has reached the probes – an alarm has been triggered |
| Off | The LED indicator is turned off in the settings, or the device is switched off |
Choosing the installation location
Water Guard is designed to detect water leaks from indoor plumbing, bathtubs, sinks, washing machines, dishwashers, water heaters, storage tanks, or pool filtration equipment. Place the detector at the lowest point of the monitored area, where leaking water would most likely reach first.
Placement on the floor
For free-standing installation, place the detector directly on the floor so that its bottom side with the three contact probes is in direct contact with the floor at the expected leak location.
Setting the probe sensitivity
Before final installation, set the height of the positive probe according to the floor type and the required sensitivity – smooth floors (tiles, PVC) usually require a lower probe position (higher sensitivity) than uneven surfaces.
Signal strength
Before final installation, test the signal strength in the app (Signal strength test). If the signal is weak, move the detector or use a signal repeater.
Where not to install the detector
- In places exposed to direct sunlight or near heat sources.
- In damp, dusty, or smoky areas.
- In poorly ventilated spaces – do not block the device's ventilation.
- In locations with a weak hub radio signal.
Detector installation
Water Guard supports two installation methods – free-standing installation (placing the entire device on the floor) and fixed installation (splitting it into a compact sensor on the floor and the detector body mounted higher on the wall or on a mounting panel).
Free-standing installation (placing on the floor)
- Turn the detector body in the direction of the arrow until the back cover clicks into place.
- Set the height of the positive probe using the sensitivity adjustment screw (turning it clockwise increases the sensitivity, turning it counterclockwise decreases it).
- Place the detector on the floor at the location where a water leak may occur.
Fixed installation (mounting on a wall or mounting panel)
- Turn the mounting panel in the direction of the arrow and remove it from the detector.
- Drill 2 holes in the wall according to the hole positions and insert the wall plugs. Use suitable screws and a screwdriver to attach the back cover (mounting panel) to the wall.
- Secure the detector body in the mounting panel by sliding it in the direction of the arrow.
- Place the compact sensor with three contacts on the floor at the expected water leak location and set the height of the positive probe using the sensitivity adjustment screw.
Functionality Test
After installation, verify the correct function of the detector:
- Signal strength test – run a test in the app and verify the quality of the radio connection with the hub.
- Detection test – start the detector test in the app and verify that the device responds.
- Probe sensitivity test – apply a small amount of water to the probes and verify that the LED indicator briefly (0.4 s) flashes green and a water leak alarm notification is received in the ProSAFE app.
Battery replacement
The detector is powered by 1× CR123A lithium battery (3 H) with a lifespan of up to 3 years (with one alarm activation per day). The ProSAFE app will notify you of a low battery.
- Turn the detector body in the direction of the arrow until the back cover releases, and turn off the device using the power switch.
- Loosen the screws on the back and remove the discharged battery.
- Insert a new CR123A battery. Observe the correct polarity.
- Tighten the screws, turn on the device using the power switch, and turn the detector body in the direction of the arrow until the back cover clicks into place.
Maintenance
- Keep the probes and the detector housing clean – deposits and dirt on the contacts can reduce detection sensitivity. Wipe them with a dry, soft cloth; do not use aggressive cleaning agents.
- After each alarm trigger, thoroughly dry the detector and the floor beneath it.
- Regularly check the battery status and signal strength in the ProSAFE app.
- Perform a detection test after every manipulation of the detector.
- Do not disassemble the detector. The device has IPX5 protection (resistance to splashing water) – it is not a waterproof housing intended for permanent immersion.
Technical Specifications
| Detection parameters | |
| Sensor | Water leak sensor – 3 contact probes (2× negative, 1× positive) |
| Sensitivity | Adjustable via the height of the positive probe |
| Temperature sensor | |
| Measuring range | −15 °C to +65 °C (indoors) |
| Accuracy / resolution | ±1 °C / 1 °C |
| Wireless transmission – SAFE Keeper | |
| Carrier frequency | 868.0–868.6 MHz |
| Transmitter power (EIRP) | limit 25 mW |
| Communication distance | Up to 1,200 m in open space |
| Communication type | Two-way |
| Encryption | AES128 |
| Frequency hopping | Yes (automatic) |
| Interface and functions | |
| Indication | 1× green LED |
| Control Devices | 1× power button (switch) |
| Tamper contact | No |
| Remote update | Yes (cloud) |
| Low battery notification | Yes |
| Test mode | Signal strength test, detection test |
| General | |
| Power supply | 1× CR123A battery, 3 V (included) |
| Power consumption | Max. 144 mW |
| Current draw | ≤28.5 µA (operation), ≤5.8 mA (alarm) |
| Battery life | 3 years with one alarm activation per day |
| Operating temperature | −10 °C to +55 °C (indoors) |
| Operating humidity | 10–90 % RH |
| Storage temperature / humidity | −10 °C to +55 °C / 10–90% RH |
| Ingress protection rating | IPX5 |
| Housing material | PC + ABS, white |
| Product dimensions | 84,7 × 84,7 × 32,5 mm |
| Package dimensions | 135 × 98 × 56 mm |
| Weight | Net 100 g / gross 181 g |
| Installation | Freely on the floor, or on a mounting panel / wall |
| Compatibility | Hub 2 Plus LTE (SAFE 38300) |
| Certification | CE |
Package Contents
- Water Guard detector – 1 pcs
- Double-sided adhesive tape – 1 pcs
- Mounting kit (screws, wall plugs) – 1 set
- Quick user guide – 1 pcs
- Legal and regulatory information – 1 pcs
- QR code with the user manual – 1 pcs
Safety Notices
- Operate and store the device only within the permitted temperature and humidity range.
- Do not install the detector in locations exposed to direct sunlight or near heat sources.
- IPX5 protection protects the device against splashing water from all directions; however, it is not a waterproof design intended for submersion.
- Keep batteries out of reach of children. Do not throw batteries into fire, do not crush or cut them – risk of explosion. If battery ingestion is suspected, seek medical help immediately.
- Replace a discharged battery only with a battery of the same type (CR123A).
- Do not dispose of the product with regular household waste – hand it in for recycling through the electrical equipment take-back system.
Warranty
The SAFE Water Guard device is provided with a warranty of 36 months from the date of sale. The warranty does not cover the battery or defects caused by failure to follow the instructions in this manual.
If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.
Gallery
Need Help?
SAFE HOME europe technical support:
Email: info@safe-home.eu · Phone: (+420) 581 222 262