Product Manuals / Fire protection

Wireless carbon monoxide detector compatible with the ProSAFE app
SAFE CO Guard (SAFE 38240)

User Manual

Updated 20. 8. 2026

Product Page
SAFE CO Guard detector

CO Guard is a wireless carbon monoxide detector with detection via an electrochemical sensor, 2nd generation, an LCD display and a design allowing free-standing installation on a horizontal surface. The detector is designed for indoor installation, where it can operate as part of the SAFE security system with hub support, or completely autonomously as a standalone detector. Power for up to 3 years is provided by a replaceable CR123A lithium battery.

30 ppmdetection sensitivity from
85 dBacoustic alarm
1000 mradio signal range
3 yearsbattery life
10 yearssensor service life
45 stemporary alarm silencing duration
24 hCOElectrochemical carbon monoxide (CO) sensor
LCD display and memory of the highest measured value
3x integrated LED indicator
Built-in siren and loud 85 dB alarm
Design with free-standing installation option
Up to 3 years of battery operation
Replaceable power battery
App for remote control and monitoring
Adding the device to the system by scanning a QR code
Radio signal range up to 1000 m
IZOVAX protection
Indoor installation
Data encryption using the AES algorithm with rolling code
Protection against radio signal interference
Two-way information transfer between devices
Simple device installation
EN 14604:2009 certification and 10-year warranty

Preface

General

This user manual introduces the installation, functions, and operation of the wireless carbon monoxide detector (hereinafter the "detector"). Before using the device, read the manual carefully and keep it for future reference.

Safety Instructions

The following signal words may appear in the user manual:

Signal WordMeaning
DANGERIndicates a high potential hazard that, if not avoided, may result in death or serious injury.
WARNINGIndicates a medium or low potential hazard that could cause minor or moderate injury if not avoided.
CAUTIONIndicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome.
TIPProvides methods to help you solve a problem or save time.
NOTEProvides additional information, such as emphasis and supplementary text.

Revision History

VersionRevision ContentRelease Date
V1.0.0First release.August 2026

Privacy Notice

As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the Manual

Important Safeguards and Warnings

This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.

Operating Requirements

CAUTION

Installation Requirements

WARNING
CAUTION

What to do in the event of a CO alarm

If the detector detects a dangerous concentration of carbon monoxide, it triggers a loud alarm signal (85 dB) accompanied by the red LED indicator flashing Alarm – a short buzzer beep once per second together with the LED flashing once per second, while the display shows the currently measured CO concentration in ppm units.

By triggering the alarm, the detector warns of the presence of carbon monoxide (CO), which can cause death. In the event of an alarm, we recommend:
  • Stay calm and open all doors and windows. Stop using all fuel-burning appliances and, if possible, ensure they are switched off (e.g., close the emergency shut-off valve on gas appliances).
  • Press the TEST/Silence button to temporarily silence the alarm (for 45 seconds). If the warning signal persists, inform other occupants and evacuate the building – leave the doors and windows open and do not re-enter the premises.
  • Obtain medical help for anyone showing symptoms of CO poisoning (headache, nausea), and inform the doctor of suspected carbon monoxide inhalation.
  • Call the emergency line 112, the gas company's emergency number, or the appliance service organization. Ensure the source of the CO leak is identified and removed.
CO detectors can be affected by external conditions (e.g., heavy air pollution from road traffic in cold weather) – in such cases, opening doors and windows may actually increase the CO level.

If the area is ventilated after the alarm is triggered, the carbon monoxide may disperse before help arrives. Even in that case, the source of the CO leak must be identified and its cause removed. Do not start using any fuel-burning appliances again until they have been inspected and cleaned by a competent person in accordance with national regulations.

Never ignore the CO detector's warning alarm signal! High CO concentration can quickly lead to a dangerous situation.

Time to alarm activation depending on CO concentration

CO concentrationTime to alarm activation
30 ppm120 min
50 ppm60 to 90 min
100 ppm10 to 40 min
300 ppmup to 3 min

About carbon monoxide (CO)

What is carbon monoxide

Carbon monoxide is the main gaseous product of incomplete (uncontrolled) combustion of carbon-based materials. It is a colorless, non-irritating gas without taste or smell, whose toxic effects adversely affect the blood's ability to carry oxygen. Exposure to a high concentration of CO can cause serious tissue damage or be fatal. The severity of poisoning depends on the concentration (ppm) and duration of exposure – CO is a cumulative poison, and symptoms can be caused even by long-term exposure to low concentrations (>10 ppm).

CO concentration (ppm)Effects on adults
100 ppmMild headache, nausea, fatigue (flu-like symptoms)
200 ppmDizziness and headache within 2–3 hours
300 ppmNausea, headaches at the temples and forehead, drowsiness, disorientation, and increased heart rate; life-threatening after more than 3 hours of exposure
400 ppmSevere headache, convulsions, failure of vital organs; death may occur within 2–3 hours
  • This device may not prevent the effects of continuous exposure to carbon monoxide and will not fully protect individuals against special hazards.
  • The device detects only carbon monoxide (CO); it does not detect other gases, smoke, or flame. In case of any doubt about the cause of the alarm, a dangerous CO level should be assumed and occupants should be evacuated.

Possible sources of carbon monoxide

CO is produced by the incomplete combustion of carbon-based fuels (coal, wood, charcoal, heating oil, kerosene, gasoline, propane, butane, natural gas).

Basic steps to protect against CO poisoning

Functional Elements

Front view of the CO Guard detector with LCD display, TEST/Silence button, and Alarm, Fault, and Power LED indicators
CO Guard detector – front view
  1. Buzzer – acoustically (85 dB) informs about the device's individual operating states, accompanied by the LED indicator's visual signal.
  2. LCD display – shows current status information, the carbon monoxide concentration, or the highest measured CO value in ppm units.
  3. Red Alarm LED indicator – indicates a CO alarm.
  4. Yellow Fault LED indicator – indicates a fault.
  5. Green Power LED indicator – indicates power.
  6. TEST / Silence button – verifies device functionality, is used to temporarily silence the acoustic alarm signal, recall the memory of the highest measured values, and reset.
  7. Battery compartment (back) – replaceable CR123A battery.

Operating Principle

CO Guard continuously monitors, detects, and signals the presence of carbon monoxide in living spaces using advanced technology of an electrochemical sensor, 2nd generation , with high sensitivity and stable performance, capable of detecting even very low CO concentrations (from 30 ppm). The sensor does not require further calibration during its service life (more than 10 years). The detector combines a minimalist design with advanced hardware and intelligent software – an integrated loud siren (85 dB), an LCD display with memory of the highest measured value, a design allowing both fixed wall mounting and free-standing installation on a horizontal surface, and two-way encrypted data transmission between the device and the hub.

When an alarm is triggered, the detector immediately relays the event to the hub, and the user receives a notification in the ProSAFE. The detector is type A, intended for both fixed and portable installations, and is certified according to the European standards EN 50291-1:2018 and EN 50291-2:2019 for carbon monoxide detectors (including caravans, motorhomes, and boats).

Local alarm signaling

Once the CO threshold concentration is reached, the detector triggers a warning signal: the red LED Alarm flashes and the buzzer beeps at a regular interval of once per second, while the display shows the currently measured CO concentration in ppm. If a hub is connected to the SAFE system, it monitors the activity of all devices and, in the event of an alarm, immediately informs the user in the ProSAFE app according to the configured settings.

In the ProSAFE app, this event is displayed as a carbon monoxide alarm; in alarm summary overviews, it is usually classified in the same category as the general signaling of a gas leak.

Temporary alarm silencing

If necessary, or in the event of a false alarm, the acoustic signal can be temporarily silenced by pressing the TEST/Silence button for 45 seconds. The detector indicates temporary silencing mode by flashing the red Alarm LED at an interval of once per second without the accompanying buzzer sound. If the CO concentration subsequently drops below the specified value, the detector automatically returns to normal operating mode.

Memory of the highest measured value

The detector has a highest-measured-value memory function – it records information about the highest measured CO concentration, which remains displayed on the screen until it is reset. Pressing the TEST/Silence button recalls, for 3 seconds, a display of "8888" and then the last highest measured value; while it is displayed, the memory can be reset by holding the button for 3 seconds. Information about the highest measured value is also available in the ProSAFE app.

Do not manually reset the memory until the source of carbon monoxide has been identified and corrected.

SAFE Keeper protocol

Communication with the hub is provided by the encrypted two-way radio protocol SAFE Keeper in the 868 MHz band:

Adding to the System

Adding a device by scanning a QR code
Adding a device by scanning a QR code

Before adding the device

  1. Install the app ProSAFE and log in to your account.
  2. Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
  3. The hub must be in the Disarmed state.
  4. Insert the CR123A power battery into the detector and activate the device by pulling out the insulating strip on the battery contact.

How to add CO Guard

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the back of the detector and click Next.
  4. On the accessory screen, select the option Wireless CO detector and continue.
  5. Following the on-screen instructions, activate the detector by pressing and holding the TEST/Silence.
  6. Wait for pairing to complete.
  7. Enter the detector name, select the area (subsystem), and complete the setup.
  8. Check the signal strength of the connection to the hub at the installation site and test the device's functionality.
If pairing fails, check that the hub is online and in the Disarmed state, and repeat the procedure.

States

You can view the current detector status in the ProSAFE app by selecting the detector in the Devices list.

ParameterMeaning
Online statusConnection between the detector and the hub
  • Online – the detector is communicating
  • Offline – loss of connection
Signal intensity (strength)Radio signal strength between the hub and the detector: no signal / very weak / weak / good / excellent
Battery capacity status100 % full / 65 % medium / 45 % sufficient / 15 % insufficient
Gas concentrationCurrent measured CO value in ppm
Connection via repeaterWhether the detector sends messages to the hub via a signal repeater (Yes/No)
Temporarily disableEnable – the detector sends alarm messages to the hub / Disable – it does not
Firmware versionCurrent detector firmware version

Settings

You can change the settings in the ProSAFE app: select the detector in the Devices list and click the edit icon.

SettingsValue
Device configurationDisplays the device's name, type, SN, and model; confirm the name change with the Save button
Area (zone)Assigning the detector to a system area
Temporarily disableEnable (default) – the detector sends alarm messages to the hub / Disable – it does not
Siren linkageWhen the alarm is triggered, the detector simultaneously activates the siren linked to the hub
Alarm and video linkageIn the event of an alarm, the event is linked to the video of the selected channel
Video channelSelection of the video channel to link with the alarm
LED indicatorOn (default) / off
  • When off, the LED does not light regardless of a reported fault or alarm
Transmission powerHigh / low / automatic – higher power extends range and increases power consumption
Signal strength detectionTest the current radio signal strength
Cloud updateRemote (online) firmware update for the device
DeleteRemoving the device from the system (swipe left in the device list)

Signaling

LCD displayLED indicatorBuzzerDevice mode
EmptyGreen (Power) flashes once every 60 sNo signalingNormal standby mode
Displays the CO concentration in ppmRed (Alarm) flashes once per secondBeeps once per secondAlarm – a CO leak has been detected. Evacuate people to fresh air and call 112
Displays the CO concentration in ppmRed (Alarm) flashes once per secondNo soundTemporary alarm silencing (45 s)
Displays the last highest valueNo signalingNo signalingHighest measured value mode – recall and reset it by holding the TEST/Silence button
3 s, "8888", then 5 with "0", then "8888" again, then 60 with "0"All 3 LEDs flash 3×Beeps 3×Test mode (by pressing the TEST/Hush button)
"Lb"Yellow (Fault) flashes 1× per 60 sBeeps 1× per 60 sLow battery voltage – replace the battery with a new one immediately
"Err"Yellow (Fault) flashes 2× per 60 sBeeps 2× per 60 sFault – clean the detector; if the notification persists, the device must be replaced
"End"Yellow (Fault) flashes 3× per 60 sBeeps 3× per 60 sEnd-of-life signaling (30 days before the end of operation) – replace the device with a new one

Choosing the installation location

CO detectors should ideally be installed in every room containing a fuel-burning appliance. We strongly recommend installing additional detectors in bedrooms and rooms where you spend a lot of time during the day – in places where you will hear the alarm even while asleep (e.g. on a nightstand in the bedroom).

Which rooms to install in

Preferably install a detector in every room with a fuel-burning appliance. Install additional devices so that audible signaling is ensured for occupants of remote rooms as well (living rooms, all bedrooms). If there are multiple appliances and the number of detectors is limited, consider:

Where in the room to install

Room with a fuel-burning appliance (stove, boiler, gas fireplace, fireplace): CO rises with the warm gas mixture, so install the detector above the level of the appliance and close to the ceiling:

Bedrooms or rooms remote from the appliance (hallways, landings): install the detector on the wall at a height 1,5–1,6 m above the floor, close to the users' breathing zone. Never install the detector at floor level – carbon monoxide is lighter than air and rarely settles near the floor.

Thanks to its free-standing design, the detector can also be placed on a horizontal surface (shelf, nightstand, windowsill) in accordance with the height recommendations above – we do not recommend mounting it fixed to the ceiling.

Caravans and boats

The detector is also suitable for caravans, motorhomes and boats. Do not install it directly above a heat or steam source and keep a distance of 1–3 m from the CO source. If you are moored next to a jetty, wall or another boat, do not leave the engine running – exhaust fumes may damage the sensor. If the caravan or boat has a single living space that is also used for sleeping, one detector is sufficient; every sleeping space separated from the fuel-burning appliance should have its own detector.

Where not to install the detector

Detector installation

The CO Guard detector can be installed in two ways – fixed mounting on a wall, or freestanding placement on a horizontal surface thanks to two stabilizing feet on the base of the device.

Wall Mounting

  1. According to the chapter Choosing the installation location select a suitable location.
  2. Using the included drilling template, drill holes at the installation site (⌀ 5 mm) and insert wall plugs into them.
  3. Place the detector's back cover (mounting plate) in position and screw it into the wall plugs using self-tapping screws.
  4. From the set of information labels, attach labels A and B to the front of the device and labels C and D to the back, in the required language.
  5. Activate the detector by pulling out the insulating strip from the battery contact.
  6. Fit the detector body onto the mounted back cover and slide it downward until it clicks securely into place.
  7. Test the device's function by pressing the TEST/Hush button – check the correct operation of the LED indicators, buzzer and LCD display (see Functionality Test).

Free-standing installation on a horizontal surface

The base design of the detector features two feet that allow flexible and stable free-standing installation on a horizontal surface (shelf, nightstand, windowsill, etc.) without the need for drilling.

  • In free-standing installation, the detector must be positioned vertically – it must not lie flat on the horizontal surface.
  • Position it so there is no risk of it being knocked over, falling, or otherwise damaged.
  • Even with free-standing installation, follow the recommended placement described in the chapter Choosing the installation location.

Functionality Test

After installation, battery replacement, or as part of regular maintenance, test the CO detector. We recommend performing an alarm test simulation at least once a week.

  1. Briefly press the TEST/Silence.
  2. All three LED indicators flash 3× (once per second) and the buzzer beeps briefly 3×.
  3. The LCD display shows for 3 seconds "8888", then for 5 seconds shows the digit "0", then again for 3 seconds shows "8888", and before the display turns off, it shows for 60 seconds the digit "0".
If the test does not proceed as described, follow the chapter Maintenance. If the problem persists, contact technical support.

Battery replacement

The detector is powered by 1× CR123A lithium battery (3 H), lasts up to 3 years. The detector is equipped with a circuit monitoring the battery status – when the low battery signal ("Lb") appears, replace the battery within 30 days, otherwise there is a risk of an unannounced failure of CO detection.

  1. Remove the detector body from the back cover / mounting plate (for free-standing installation, open the battery compartment according to the base design).
  2. Remove the depleted battery and insert a new CR123A battery. Observe the correct polarity (+/−).
  3. Fit the detector back in place and test it by pressing the TEST/Hush button.
Recommended battery types: EVE CR123A, PAIRDEER CR123A, RAMWAY CR123A, LISUN CR123A, HCB CR123A. Depending on the battery brand, the actual battery life may differ from the stated time.
The detector cannot be fitted into the holder if the power battery is not inserted. Without a battery, the device does not work and is not capable of CO detection. Replace only with a battery of the same type (CR123A), keep it out of the reach of children, do not throw it into fire, do not crush or cut it – risk of explosion. If you suspect a battery has been swallowed, seek medical help immediately.

Maintenance

Troubleshooting common problems

ProblemPossible solution
Green Power LED does not flash 1× per 60 sInsert the battery, or pull out the insulating strip from the battery contact; if the problem persists, contact technical support
Pressing the TEST/Hush button does not trigger the warning signal, or the detector detects CO but does not trigger the acoustic signalPossible hardware fault – contact the retailer or technical support
The device emits a continuous warning toneThe detector may be reacting to a large amount of volatile substances (alcohol, perfume, gasoline, paint) – move it to a place with clean air and leave it running for approx. 2 hours; if the problem persists, contact support

Technical Specifications

Detection parameters
Detection typeCarbon monoxide (CO)
SensorElectrochemical CO sensor, 2nd generation
Sensitivity / rangeDetection from 30 ppm
Device typeA (fixed and portable installation)
CalibrationNot required during the sensor's service life
Detection certificationEN 50291-1:2018; EN 50291-1:2018/AC:2021; EN 50291-2:2019 (residential trailers, caravans, boats); BS EN 50291-1:2018
Wireless transmission – SAFE Keeper
Carrier frequency868.0–868.6 MHz
Transmitter power (EIRP)limit 35,5 mW
Communication distanceUp to 1,000 m in open space
Communication typeTwo-way
EncryptionAES128 with rolling code
Frequency hoppingYes (automatic)
Interface and functions
Indication3× LED (red Alarm, yellow Fault, green Power) + LCD display
Control Devices1× TEST / Hush / value memory recall button
Tamper contactNo
Remote updateYes (cloud)
Low battery notificationYes
Memory of the highest measured valueYes
Temporary alarm silencingYes (45 s)
Test modeYes (TEST button)
General
Power supply1× lithium CR123A battery, 3 V (replaceable, included)
Current drawOperation ≤20 µA; alarm ≤20 mA
Battery lifeUp to 3 years under normal operation
Device service life10 years from the installation date
Operating temperature−10 °C to +40 °C
Operating humidityup to 95 % RH, non-condensing
Storage / transport temperature−20 °C to +60 °C
Storage / transport humidity5–95 % RH, non-condensing
Ingress protection ratingIP30
Housing materialPC + ABS, white
Dimensions115,5 × 71,1 × 28,9 mm
Weight18,2 g (with battery)
InstallationOn the wall, or freestanding on a horizontal surface
CompatibilityHub 2 Plus LTE (SAFE 38300)
EAN0728204235188
CertificationCE; EN 62479:2010; EN 50663:2017; EN 50270:2015; EN 301 489-1 V2.2.3; EN 301 489-3 V2.1.1; EN 300 220-2 V3.1.1; EN IEC 63000:2018

Package Contents

  1. Wireless CO Guard detector – 1 pcs
  2. Drilling template – 1 pcs
  3. Self-tapping screws – 2 pcs
  4. Wall plugs – 2 pcs
  5. CR123A battery – 1 pcs
  6. User manual with a set of information labels – 1 pcs

Safety Notices

Warranty

A warranty is provided for the SAFE CO Guard device 36 months from the date of sale (excluding the battery). The warranty does not cover defects caused by failure to follow the instructions in this manual, damage, modification, or improper use of the product.

If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.

Gallery

Need Help?

SAFE HOME europe technical support:
Email: info@safe-home.eu  ·  Phone: (+420) 581 222 262
Website: www.smart-safe.eu