SAFE Rep Signal Repeater

SAFE Rep is a smart radio signal repeater for the SAFE security system. Thick concrete walls, large spaces, or a complicated building layout can all significantly weaken the reliability of wireless communication. The repeater extends the range of the encrypted protocol SAFE Keeper and allows connecting up to 128 wireless devices, significantly expanding the coverage and capacity of your system. It is powered from the 230 V mains, and in the event of a power outage it is equipped with a backup battery.

128wireless devices
2 000 msignal range (open space)
4×repeaters in one system
35 hbackup battery life
3communication paths to the hub
AES-128encryption with rolling code
Supports connecting up to 128 peripherals
Supports detectors with photo verification of alarms
Supports transmission of image and audio data
3 communication channels: Ethernet, Wi-Fi, and RF
Wide range of operating temperature and humidity
Radio signal range up to 2000 m
Supports offline linkage and communication
Ethernet as an alternative communication channel
Fast image transmission over long distances
Interference and connection loss alerts
Adding the device to the system by scanning a QR code
Automatic retuning to an interference-free channel
Up to 6 Rep repeaters in the system
Built-in LED status indicator
AP mode for quick network configuration
Cloud-based device firmware update
Backup battery for up to 12 hours of operation
Resistance to cyberattacks
Data encryption using the AES algorithm with rolling code
Protection against radio signal interference
Two-way information transfer between devices
Dual antenna for wider radio signal coverage
Tamper protection against sabotage and unauthorized manipulation of the device
Security grade 2 according to ČSN EN 50131

Preface

General

This user manual introduces the installation, functions, and operation of the wireless signal repeater (hereinafter referred to as the "repeater"). Before using the device, please read this manual carefully and keep it for future reference.

Safety Instructions

The following signal words may appear in the user manual:

Signal WordMeaning
DANGERIndicates a high potential hazard that, if not avoided, may result in death or serious injury.
WARNINGIndicates a medium or low potential hazard that could cause minor or moderate injury if not avoided.
CAUTIONIndicates a potential risk that could lead to property damage, data loss, reduced performance, or an unpredictable outcome.
TIPProvides methods to help you solve a problem or save time.
NOTEProvides additional information, such as emphasis and supplementary text.

Revision History

VersionRevision ContentRelease Date
V1.0.0First release.August 2026

Privacy Notice

As a device user or data controller, you may collect personal data of others, such as their face, fingerprints, and license plate number. You must comply with local privacy laws and regulations to protect the legitimate rights and interests of other people by implementing measures that include, among others: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the Manual

Important Safeguards and Warnings

This section contains information on the proper handling of the product, risk prevention, and prevention of property damage. Read it carefully before using the device and follow the instructions provided when using it.

Operating Requirements

CAUTION

Installation Requirements

WARNING
CAUTION

Functional Elements

Functional Elements of the SAFE Rep Repeater – Front, Rear Panel, and Mounting Plate
Functional Elements of the SAFE Rep Repeater
  1. LED indicator – indicates pairing, operating status, and faults (see Signaling).
  2. Power connector – connect the power cable to the mains.
  3. AP button – hold for 2 seconds to enable Wi-Fi access point mode for configuring the connection from your phone; hold again for 2 seconds to disable AP mode.
  4. Tamper contact – triggers an alarm when the repeater is removed from the mounting plate.
  5. Reset button – hold for 10 seconds to restart the repeater and restore factory settings.
  6. Ethernet Connector – connect a network cable to the router.
  7. Power switch – turns the repeater on and off.
  8. Rear Cover / Mounting Plate – opening the cover triggers a tamper alarm.

Operating Principle

The SAFE Rep signal repeater extends the range of wireless communication between the hub and the peripherals of the SAFE system. It is placed between the hub and more distant or structurally shielded peripherals, acting as an intermediate link that receives the signal and retransmits it further. Up to 6 repeaters, allowing coverage of even large or complex premises.

Extending the Range of SAFE Keeper

Communication between the hub, the repeater, and the peripherals is provided by the encrypted bidirectional radio protocol SAFE Keeper in the 868 MHz with a range of up to 2 000 m in open space. The repeater supports connecting up to 128 wireless devices and transmission is secured with AES-128 encryption using a rolling code and frequency hopping as protection against interference.

Switching Devices to the Repeater

Each peripheral in the system communicates either directly with the hub or through the repeater – depending on which connection is better. The communication path can be set in two ways:

A peripheral manually switched to the repeater is marked in the peripheral list with a manual communication mode flag.

Roaming of Key Fobs and Panic Buttons

Key fobs and panic buttons are not tied to one specific repeater. The device is added to the system once and then works within range of any repeater as well as the hub itself – when moving between their coverage areas, communication is handed over automatically, without user intervention and without having to reassign the device. A panic button therefore works across the entire area covered by the system, not only where it was added.

Thanks to roaming, coverage can be extended with additional repeaters without having to walk the site again and reassign control devices that have already been added.

Power Supply and Heartbeat Signal

The repeater is powered from the 230 V mains and is equipped with a built-in backup battery in case of a power outage (see Power supply and backup battery). The hub and the repeater regularly exchange, with each other and with connected peripherals, a heartbeat signal – if the connection to the repeater or to a peripheral behind it is missing for an extended period, the system reports it as offline.

Three Communication Paths to the Hub

The repeater can be connected to the hub in three ways – via a wired Ethernet network, a wireless Wi-Fi network, or directly via the SAFE radio protocol Keeper (AirFly). The selected path is set when adding the repeater to the system (see Adding to the System) and can subsequently be changed in the repeater settings.

Adding to the System

Adding a device by scanning a QR code
Adding a device by scanning a QR code

Before Adding the Repeater

  1. Install the app ProSAFE and log in to your account.
  2. Make sure you have a compatible hub added in the app (Hub 2 Plus LTE, SAFE 38300) with a stable internet connection.
  3. The hub must be in the Disarmed state.
  4. Temporarily place the repeater at the intended installation location and perform a signal strength test – the recommended minimum value is 2 bars.
App version 1.99.620 or later and hub firmware 2.000.0000000.0.R.20231220 or later are required.

How to Add a Repeater – Radio Connection (AirFly)

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the bottom of the repeater, and tap Next.
  4. Once the repeater is found, tap Next.
  5. Enter a name for the repeater, select an area (zone), and tap Next.
  6. Following the on-screen instructions, switch the repeater's power switch from off to on – the LED indicator will start blinking green – and tap Next.
  7. Wait for pairing to complete and tap OK.

How to Add a Repeater – Wired Ethernet Network

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Connect an Ethernet cable to the repeater. The repeater and the hub must be on the same network.
  4. Scan the QR code with the serial number on the bottom of the repeater, and tap Next.
  5. In the top right corner, tap the menu ⋯, select Add via Network and click Next.
  6. Wait for pairing to complete and tap OK.

How to Add a Repeater – Wireless Wi-Fi Network

  1. In the ProSAFE app, open your hub and click Device.
  2. Click + Add device.
  3. Scan the QR code with the serial number on the bottom of the repeater, and tap Next.
  4. Enter and confirm the Wi-Fi network password and tap Next.
  5. Click Select Network Configuration Method and select Wi-Fi.
  6. Connect both the repeater and the hub to the same Wi-Fi network.
  7. Wait for pairing to complete and tap OK.
If pairing fails, check that the hub is online and in the Disarmed state, verify the selected network connection, and repeat the procedure.

States

You can view the current status of the repeater in the ProSAFE app by selecting the repeater in the peripheral list.

ParameterMeaning
Device numberSequence number of the repeater in the system
Online statusConnection between the repeater and the hub
  • Online – the repeater is communicating
  • Offline – loss of connection
Signal strengthRadio signal level (SAFE Keeper) between the hub and the repeater: none / low / weak / good / excellent
RF-HDSignal level on the dedicated channel for image data transmission between the hub and the repeater
Wi-Fi signal strengthStatus of the repeater's internet connection via Wi-Fi; the recommended minimum value is 2 bars
Wi-FiStatus of the repeater's Wi-Fi connection: Connected / Not Connected
External power supplyMains power status: Connected / Not Connected – when disconnected, the repeater runs on the backup battery
Battery levelRemaining backup battery capacity in percent
Temporarily disableTemporary bypass status, automatically restored after the system is disarmed
  • Yes – alarm information is not sent to the hub
  • Cover only – all information except tamper alarms is sent to the hub
  • No icon – the function is off, all information is sent
Permanently DeactivatePermanent deactivation status of the repeater – unlike temporary bypass, it is not automatically restored after the system is disarmed
  • Yes – alarm information is not sent to the hub
  • Cover only – all information except tamper alarms is sent to the hub
  • No icon – the function is off, all information is sent
Tamper statusOpen / Closed – indicates removal of the repeater from the mounting plate or opening of the cover
Firmware versionCurrent firmware version of the repeater

Settings

You can adjust the settings in the ProSAFE app: select the repeater in the peripheral list and tap the edit icon.

SettingsValue
Device nameCustom name for the repeater; displayed in the peripheral list and in notifications
Area (zone)Assignment of the repeater to a system area
Temporarily disableYes / Cover Only / No Icon (Off) – the status is automatically restored after the system is disarmed
Permanently DeactivateYes / Cover Only / No Icon (Off) – unlike temporary bypass, the status is not automatically restored after the system is disarmed
LED indicatorOn (default) / Off – when off, the LED does not light regardless of the repeater's status (alarm, fault, arming, disarming)
Switching Devices to the RepeaterAutomatic Mode (default) – the peripheral selects the path based on signal strength / Manual Mode – use the "+" button next to the peripheral to permanently assign it to this repeater as its communication path
Network
  • Ethernet – setting of the IP address, subnet mask, gateway, and MAC address; DHCP can be enabled for automatic assignment of these values; the Ethernet Outage Detection function verifies the functionality of the wired connection between the repeater and the hub
  • Wi-Fi – selecting a Wi-Fi network from the list, entering the password, and connecting
Login CredentialsDisplay of the repeater's login name and password; the password can be changed, the username cannot be edited
Linkage on Connection Loss
  • Siren linkage – if a communication error occurs between the repeater and the hub, an alarm signal from a manually assigned peripheral will trigger a siren that is also manually assigned to this repeater
  • Linkage Scenario – selection of up to 8 alarm scenes that will remain available even if the connection to the hub is lost
AirFly Fault DetectionAutomatic check of the functionality of the radio connection (AirFly) between the repeater and the hub
RF-HD Transmission SpeedHigh Speed – faster data transmission but limited range; cannot be enabled when the repeater is connected via Wi-Fi / Normal (default) – better wall penetration, slower transmission
RF-HD TestVerification of the RF-HD signal strength and successful connection of the repeater to the hub; helps find the location with the strongest signal for installation
Signal strength testVerification of the current signal strength to select a suitable installation location
Device TestVerification of the functionality of a peripheral connected through this repeater
Transmission powerHigh / low / automatic – higher power extends the range and increases consumption
  • When Low is selected, the repeater switches to reduced-sensitivity mode until you change the power setting again
Automatic DownloadThe update package is downloaded automatically after a new version is released
Firmware updateDisplay of the repeater's current firmware version and updating it to the latest version
User ManualDisplay of the repeater's user manual

Signaling

LED indicationEvent
Continuously lit greenThe repeater is operating normally
Blinking GreenPairing mode
Blinking Green QuicklyTransmit power is set to low (reduced-sensitivity mode) – blinks faster than in pairing mode
Solid YellowThe repeater is offline
Flashes yellowRepeater fault, for example a tamper alarm being triggered
Blinking Blue SlowlyThe repeater is in access point (AP) mode. An uninitialized repeater that has not yet been connected to the hub is in this mode by default – the LED may not light up in this case

Choosing the installation location

Place the repeater at a location along the path between the hub and more distant or structurally shielded peripherals so that it improves signal coverage in problem areas of the building. Both wall mounting and free-standing desktop placement are supported.

Signal strength

Before final mounting, temporarily place the repeater at the intended location, connect the power, and run a Signal strength test between the hub and the repeater. The recommended minimum value is 2 bars. If you use the RF-HD channel for image data transmission, also verify its strength using the RF-HD Test.

Where Not to Install the Repeater

  1. Near metal structures, distribution boards, or large appliances that shield the radio signal.
  2. In damp, dusty, or smoky areas.
  3. In places exposed to direct sunlight or near heat sources.
  4. In poorly ventilated areas, and do not otherwise block its ventilation.
  5. In locations with a weak signal between the hub and the planned location of the repeater.
If you are connecting the repeater with an Ethernet cable, choose an installation location with an available network outlet or within reach of structured cabling to the router.

Repeater Installation

The repeater can be mounted on a wall or placed freely on a desk (desktop). Before drilling, we recommend temporarily placing the repeater at the installation location, connecting the power, and performing a signal strength test.

Opening the Cover and Preparing the Mounting Plate

  1. Loosen the screw at the bottom of the repeater and open it.
  2. Remove the mounting plate by sliding it in the direction of the arrow (PULL).
Loosening the Screw at the Bottom and Opening the Repeater
Loosening the Retaining Screw and Opening the Repeater
Removing the Mounting Plate by Sliding in the Direction of the PULL Arrow
Removing the Mounting Plate (PULL)

Connecting the Power Supply

  1. Connect the power cable to a mains outlet and the other end to the repeater's power connector.
  2. If you want to connect the repeater via a wired network, connect an Ethernet cable to the Ethernet connector and the other end to the router.
  3. Use the power switch to turn the repeater to the ON position and add it to the system (see Adding to the System).
Connecting the Power Cable to the Mains and the Ethernet Cable to the Router
Connecting the Power Cable to the Mains and the Ethernet Cable to the Router

Wall Mounting

  1. Determine the position of the mounting holes, drill them into the wall, and insert the wall plugs (included in the package).
  2. Hold the mounting plate against the wall, align the holes with the wall plugs, and secure it with ST4×25 mm.
  3. Fit the repeater body onto the mounting plate from top to bottom and secure it with M3×8 mm countersunk-head screws at the bottom.
Drilling the Mounting Holes and Attaching the Mounting Plate to the Wall
Drilling the Holes and Attaching the Mounting Plate to the Wall
Fitting the Repeater onto the Mounting Plate and Securing It with a Screw
Fitting the Repeater onto the Mounting Plate and Securing It with a Screw
The repeater can also be operated without wall mounting – placed freely on a desk (desktop) within reach of a power outlet and at the required signal strength.

Functionality Test

After installation, verify that the repeater is functioning correctly:

  1. Signal strength test – in the app, run a test and verify that the signal between the hub and the repeater reaches at least 2 bars.
  2. RF-HD Test – for installations using image data transmission, also verify the strength of this channel.
  3. Device Test – for peripherals switched to the repeater, verify that they are communicating and sending messages to the hub.
  4. Check the Status External Power: Connected and the charge status of the backup battery in the repeater's status overview.
Adding a Device and Testing Signal Strength in the App
Adding a Device and Testing Signal Strength in the App

Power supply and backup battery

The repeater is powered from the 100–240 VAC, 50/60 Hz mains supply using the included power cable. In case of a mains power outage, it is equipped with a built-in rechargeable lithium battery, 3.7 V / 4750 mAh with a standby time of up to 35 hours (when connected to the hub only via the SAFE radio protocol Keeper), or up to 18 hours when connected via Ethernet, Wi-Fi, or the high-speed RF-HD channel.

Connect the repeater only to the power cable supplied by the manufacturer and to a properly grounded outlet. Do not disconnect the power cable while the repeater is switched on.

Maintenance

Technical Specifications

Interface
Wireless Elements128 wireless peripheral channels
Network ModesEthernet, Wi-Fi
Network port1× RJ-45, 10 Mbps / 100 Mbps
Function
LED indicator1× multicolor (alarm, arming/disarming, cloud connection, fault, AP, pairing)
ButtonsPower button, Reset button, AP mode button
Remote updateYes (cloud)
Tamper contactYes
Low battery detectionYes
Pairing modeAutomatic / Manual
Wireless transmission – SAFE Keeper
Carrier frequency868.0–868.6 MHz
Transmitter power (EIRP)limit 25 mW
Communication typeTwo-way
Communication distanceUp to 2,000 m in open space
EncryptionAES-128
Frequency hoppingYes (automatic)
Wi-Fi
Wi-Fi StandardIEEE 802.11b/g/n
Wi-Fi Frequency Range2400–2483.5 MHz
Wi-Fi Transmit Power≤ 20 dBm @ 2400–2483.5 MHz
General
Power supply100–240 VAC, 50/60 Hz, 0.4 A
Backup batteryLithium 3.7 V / 4750 mAh; standby time up to 35 h (SAFE Keeper) / 18 h (Ethernet, Wi-Fi, RF-HD); charges to 80% in approximately 11 h
Power consumption22 W (max.)
Operating temperatureWith a charged battery: −10 °C to +50 °C; while charging the battery: 0 °C to +45 °C
Operating humidity10–90 % RH
Storage temperature−10 °C to +55 °C
Storage humidity10–90 % RH
Housing materialPC + ABS, white
Dimensions174.8 × 174.8 × 38.3 mm
Weight510 g
InstallationWall-mounted, or freestanding on a desk (desktop)
CompatibilityHub 2 Plus LTE (SAFE 38300)
CertificationCE; EN 50131-1; EN 50131-3; EN 50131-5-3; EN 50131-6; EN 50131-10; EN 50136-2; Security Grade 2; Environmental Class II
Dimensional drawing of the repeater: 174.8 × 174.8 × 38.3 mm
Repeater Dimensions (mm)

Package Contents

Contents of the SAFE Rep Repeater Package
  1. SAFE Rep Repeater – 1 pcs
  2. Ethernet Cable – 1 pcs
  3. Power Cable – 1 pcs
  4. Quick user guide – 1 pcs
  5. Legal and regulatory information – 1 pcs
  6. Mounting kit (screws, wall plugs) – 1 set
  7. QR code with the user manual – 1 pcs

Safety Notices

Warranty

The SAFE Rep device is covered by a warranty 36 months from the date of sale. The warranty does not cover defects caused by failure to follow the instructions provided in this manual.

If you experience any problems with the device, contact technical support first – most situations can be resolved remotely.

Need Help?

SAFE HOME europe technical support:
Email: info@safe-home.eu  ·  Phone: (+420) 581 222 262
Website: www.smart-safe.eu