Wired output expander with 8 relay channels
SAFE IO Relay Board (SAFE 38183)

User manual

Updated 21 October 2026

Product page
SAFE IO Relay Board module

SAFE IO Relay Board extends the security system with eight relay outputs. With the Hub 2 Plus LTE it communicates over the bus RS-485 via the Serial Bridge converter, turning a purely wireless Hub into a hybrid one. One bus can have up to 16 modules. Each output is switched with a jumper between normally closed and normally open contact and can carry a load of 30 V DC / 500 mA – from sirens and beacons through electric locks and roller shutters to shutting off the water or gas supply.

8relay outputs
16modules on the bus
300 mbus length
30 V / 0,5 Aoutput load rating
12 V DCpower supply
1,8 Wconsumption
8 relay outputs switchable NO / NC
Output load rating 30 V DC / 500 mA
Control of wired elements from the SAFE system
Remote update using client software
Integrated LED indicator
External 12 V DC power supply
Wide permitted operating temperature and humidity range

Foreword

General

This user manual describes the installation, functions and operation of the wired output expander (hereinafter the “module”). Read the manual carefully before using the device and keep it for future reference.

Safety instructions

The following signal words may appear in the user manual:

Signal wordMeaning
NEBEZPEČÍIndicates a high potential hazard which, if not avoided, may result in death or serious injury.
VAROVÁNÍIndicates a medium or low potential hazard which, if not avoided, could result in minor or moderate injury.
UPOZORNĚNÍIndicates a potential risk which could lead to property damage, data loss, reduced performance or an unpredictable result.
TIPProvides methods to help you solve a problem or save time.
POZNÁMKAProvides additional information, such as emphasis or a supplement to the text.

Revision history

VersionRevision contentRelease date
V1.0.0First release.September 2026
V1.0.1Technical specifications corrected according to the manufacturer's documents.October 2026
V1.0.2Photo gallery added.October 2026

Privacy notice

As a user of the device or a data controller, you may collect the personal data of others, such as their face, fingerprints and licence plate number. You must comply with local privacy protection laws and regulations in order to protect the legitimate rights and interests of other people by taking measures which include, but are not limited to: providing clear and visible identification to inform people of the existence of the monitored area and providing the required contact information.

About the manual

Important precautions and warnings

This section contains information on the correct handling of the product, risk prevention and prevention of property damage. Read it carefully before using the device and follow the instructions provided while using it.

Operating requirements

UPOZORNĚNÍ

Installation requirements

VAROVÁNÍ
UPOZORNĚNÍ

Functional elements

The module is a populated printed circuit board with screw terminal blocks around its edge. The labels on the board correspond to the designations in the terminal tables below.

IO Relay Board module with description of terminals, DIP switch and jumpers
Layout of the elements on the board
  1. DIP switch K1 (top left) – four positions used to set the module address on the bus. The up position is ON.
  2. Power and bus terminal block (top right) – 485B, 485A, GND, 12V.
  3. Relay output terminal block (bottom) – pairs NO1/COM1 up to NO8/COM8, descending from NO8 on the left.
  4. Jumpers at each relay – mode selection between NO a NC; a legend with pin numbers 1–2–3 is printed on the board.
  5. LED indicators – indicate the power and operation of the module.
Cables can be routed out of the front, the back or the bottom – the terminal blocks thus remain covered and no wires protrude anywhere.

Principle of operation

SAFE IO Relay Board extends the security system with eight relay outputs. With the Hub 2 Plus LTE communicates over the RS-485 bus via the converter Serial Bridge. It is intended for installations where a larger number of wired devices need to be controlled – this turns a wireless Hub into a hybrid one.

Eight independent outputs

Each output is a potential-free relay contact which is switched with a jumper on the board between normally closed (NC) a normally open (NO) mode, and works in both pulse and bistable mode. The load rating of one output is 30 V DC / 500 mA.

Typical use

Switching several lighting circuits, controlling electric locks and roller shutters, multi-level alarm indication using sirens and beacons, instantly shutting off the water or gas supply, and controlling ventilation and air conditioning or outdoor lighting.

Automation scenes

Events from connected devices can trigger SAFE system scenes – lock the doors, switch on the lights, disconnect appliances. They can be linked with other elements of the system, for example Power Relay, Dry Relay or Socket.

Firmware update

The module firmware is updated remotely using client software, so the module does not have to be dismounted for this purpose.

Bus connection

All four terminals are in one terminal block at the top right of the board. The module communicates with the Hub Hub 2 Plus LTE over the bus RS-485. The Hub has an RS-232 serial port on its board, so a converter is inserted between them SAFE Serial Bridge. Without it the module cannot be connected to the Hub.

TerminalWiring
12VPositive pole of the 12 V DC power supply
GNDNegative pole of the power supply, common ground
485ABus wire A – to the same branch as the other modules
485BBus wire B
The bus may be up to 300 m. The recommended cable is RVV 2 × 1.5. Wires A and B must not be swapped – the module would not report itself.
The module does not take its 12 V DC power from the bus; it is supplied separately to the +12V and GND terminals. Disconnect the power supply before wiring.

How many modules per bus

The Hub bus can have up to up to 16 modules – in any combination IO Expander Board a IO Relay Board. You can therefore build up the capacity as needed: sixteen expanders give 128 wired inputs, sixteen relay boards 128 outputs.

Topology: Hub, Serial Bridge converter and modules on the RS-485 bus
Wiring the modules on the Hub bus

Address setting

The board has a DIP switch, used to assign the module an address on the bus. Each module must have a different address; two modules with the same address interfere with each other and the system will not find them.

ParameterValue
Number of addresses16 – this is how many modules one bus can carry
SettingsBy the combination of DIP switch positions on the board
Switch orderThe address is read from the most significant bit to the least significant (H → L), as marked on the board
When to setBefore connecting power; after changing the address, disconnect the module and connect it again

Output wiring

Each of the eight outputs has a group of terminals. The mode is selected with a jumper on the board, not in the app – separately for each output.

ParameterValue
Number of outputs8
TerminalsPairs NO1 / COM1 to NO8 / COM8
ModeNO or NC, switchable with the jumper at each relay separately
Load rating30 V DC / 500 mA per output
Operating modePulse or bistable
Contact typePotential-free relay contact
Connect an appliance with a higher current draw than the output can carry via an auxiliary relay or contactor. Connecting a load above 30 V DC / 500 mA directly will burn out the contacts, and the warranty does not cover such a fault.
To switch 230 V mains appliances, use the designated SAFE system modules – Dry Relay or Power Relay.

Choosing the installation location

The module is intended for indoor environments, for installation in a junction box or distribution board. Place it so that the bus and power supply can be routed to it and so that it remains accessible for any change of address.

Where not to install the module

  1. In damp, dusty or smoky areas, or in places where condensation is likely.
  2. In direct sunlight or near heat sources.
  3. Next to power wiring and appliances that cause interference – route the bus separately from power conductors.
  4. In places where it would be freely accessible to unauthorised persons.

Installation

  1. Disconnect the power supply of the Hub and the module's power supply.
  2. Fix the board in a junction box or distribution board so that its underside does not touch a conductive surface.
  3. Set the module address with the DIP switch.
  4. Use the jumpers to select the mode of the individual outputs (NO or NC).
  5. Connect the bus 485 A a 485 B and the power supply +12V / GND.
  6. Connect the controlled elements to the output terminals.
  7. Connect the power supply and verify in the system that the module has reported itself and that the outputs switch as expected.

Maintenance

Technical specifications

Dimensional drawing of the board: 90 × 62 × 12.6 mm
Board dimensions in mm
Interface
Outputs8 alarm output channels (relay, NO/NC selection by jumper)
Communication interfaceRS-485; cabling up to max. 300 m, cable type e.g. RVV 2 × 1.5
AddressingAdjustable using the DIP switch
Connection capacityMax. 16 modules (IO Expander Boards, IO Relay Boards or a combination of them)
Optical indication1× built-in LED indicator
Functions
Line configurationNC, NO
Operating modePulse, bistable
Output load rating30 V DC / 500 mA
UpdateRemote update using client software
General
Power supply12 V DC
Power consumption1,8 W
Operating temperature−10 °C to +55 °C
Operating humidity10 % – 90 % RH, non-condensing
Dimensions90.0 × 62.0 × 12.6 mm
Weight (net)≤ 1 kg
InstallationIn a junction box
CompatibilityHub 2 Plus LTE SAFE 38300; Serial Bridge SAFE 38181; IO Expander Board SAFE 38182
ComplianceCE; EN 55032:2015+A1:2020; EN 61000-3-2:2019+A1:2021+A2:2024; EN 61000-3-3:2013+A1:2019+A2:2021; EN 55035:2017+A11:2020; EN 50130-4:2011+A1:2014; IEC 62368-1:2023 / EN IEC 62368:2024+A11:2024; EN IEC 63000:2018
Model designationSAFE 38183
EAN code0728204235201

Package contents

  1. SAFE IO Relay Board module – 1 pc
  2. Quick user guide – 1 pc

Safety notices

Warranty

The SAFE IO Relay Board device is covered by a warranty of 36 months from the date of sale. The warranty does not cover defects caused by failure to follow the instructions given in this manual.

In case of problems with the device, first contact technical support – most situations can be resolved remotely.